ANALISIS PERUBAHAN PARAMETER NUMBER OF SIGNALS AVERAGED (NSA) TERHADAP PENINGKATAN SNR DAN WAKTU PENCITRAAN PADA MRI
MRI Optimization, a hands on approach to improve image quality by manipulating scan parameter. One of this parameter is NSA, which contributes on SNR and scan time. A study about the influence of NSA shift to SNR to identify the existence of NSA shift to SNR and scan time had performed. The study ai...
Main Authors: | , |
---|---|
Format: | Thesis |
Published: |
[Yogyakarta] : Universitas Gadjah Mada
2012
|
Subjects: |
_version_ | 1826045805246545920 |
---|---|
author | , DWI ROCHMAYANTI , Prof. Dr. Ir. Thomas Sri Widodo, DEA |
author_facet | , DWI ROCHMAYANTI , Prof. Dr. Ir. Thomas Sri Widodo, DEA |
author_sort | , DWI ROCHMAYANTI |
collection | UGM |
description | MRI Optimization, a hands on approach to improve image quality by
manipulating scan parameter. One of this parameter is NSA, which contributes on
SNR and scan time. A study about the influence of NSA shift to SNR to identify
the existence of NSA shift to SNR and scan time had performed. The study aims
to determine the alteration value of SNR when NSA was changed for every
number and to obtain the NSA value which has more optimum image quality.
The study was performed in Telogorejo Hospital at Semarang with MR
modalities AirisII Hitachi 0.3 tesla by shifting NSA from 1 to 5 in cervical
vertebrae (neck) sagittal T1 weighted with spin echo sequence. The SNR of five
images were calculated with Matlab tool. SNR value was obtained by measuring
the ROI at body of vertebra, spinal cord area and discus intervertebra to attain the
signal average value. The signal average value was then devided by ROI at
backgrounds.
Experiment results show that the greater the NSA, the SNR is better and
scan time is longer. SNR of the organ corpus, medulla spinalis and diskus
intervertebra is increases from NSA 1 to 2 is 51%. When the NSA is raised to 3,
the SNR increase is 89%, for NSA 4 the SNR increase is 99%, for NSA 5 the
SNR increase is 102% . To get an SNR up to 100%, the NSA 4 is
used. Meanwhile, to get images with good SNR and imaging duration is not
long, the NSA 3 is used. |
first_indexed | 2024-03-13T22:43:12Z |
format | Thesis |
id | oai:generic.eprints.org:100602 |
institution | Universiti Gadjah Mada |
last_indexed | 2024-03-13T22:43:12Z |
publishDate | 2012 |
publisher | [Yogyakarta] : Universitas Gadjah Mada |
record_format | dspace |
spelling | oai:generic.eprints.org:1006022016-03-04T08:46:08Z https://repository.ugm.ac.id/100602/ ANALISIS PERUBAHAN PARAMETER NUMBER OF SIGNALS AVERAGED (NSA) TERHADAP PENINGKATAN SNR DAN WAKTU PENCITRAAN PADA MRI , DWI ROCHMAYANTI , Prof. Dr. Ir. Thomas Sri Widodo, DEA ETD MRI Optimization, a hands on approach to improve image quality by manipulating scan parameter. One of this parameter is NSA, which contributes on SNR and scan time. A study about the influence of NSA shift to SNR to identify the existence of NSA shift to SNR and scan time had performed. The study aims to determine the alteration value of SNR when NSA was changed for every number and to obtain the NSA value which has more optimum image quality. The study was performed in Telogorejo Hospital at Semarang with MR modalities AirisII Hitachi 0.3 tesla by shifting NSA from 1 to 5 in cervical vertebrae (neck) sagittal T1 weighted with spin echo sequence. The SNR of five images were calculated with Matlab tool. SNR value was obtained by measuring the ROI at body of vertebra, spinal cord area and discus intervertebra to attain the signal average value. The signal average value was then devided by ROI at backgrounds. Experiment results show that the greater the NSA, the SNR is better and scan time is longer. SNR of the organ corpus, medulla spinalis and diskus intervertebra is increases from NSA 1 to 2 is 51%. When the NSA is raised to 3, the SNR increase is 89%, for NSA 4 the SNR increase is 99%, for NSA 5 the SNR increase is 102% . To get an SNR up to 100%, the NSA 4 is used. Meanwhile, to get images with good SNR and imaging duration is not long, the NSA 3 is used. [Yogyakarta] : Universitas Gadjah Mada 2012 Thesis NonPeerReviewed , DWI ROCHMAYANTI and , Prof. Dr. Ir. Thomas Sri Widodo, DEA (2012) ANALISIS PERUBAHAN PARAMETER NUMBER OF SIGNALS AVERAGED (NSA) TERHADAP PENINGKATAN SNR DAN WAKTU PENCITRAAN PADA MRI. UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=57048 |
spellingShingle | ETD , DWI ROCHMAYANTI , Prof. Dr. Ir. Thomas Sri Widodo, DEA ANALISIS PERUBAHAN PARAMETER NUMBER OF SIGNALS AVERAGED (NSA) TERHADAP PENINGKATAN SNR DAN WAKTU PENCITRAAN PADA MRI |
title | ANALISIS PERUBAHAN PARAMETER NUMBER OF SIGNALS
AVERAGED (NSA) TERHADAP PENINGKATAN SNR DAN WAKTU
PENCITRAAN PADA MRI |
title_full | ANALISIS PERUBAHAN PARAMETER NUMBER OF SIGNALS
AVERAGED (NSA) TERHADAP PENINGKATAN SNR DAN WAKTU
PENCITRAAN PADA MRI |
title_fullStr | ANALISIS PERUBAHAN PARAMETER NUMBER OF SIGNALS
AVERAGED (NSA) TERHADAP PENINGKATAN SNR DAN WAKTU
PENCITRAAN PADA MRI |
title_full_unstemmed | ANALISIS PERUBAHAN PARAMETER NUMBER OF SIGNALS
AVERAGED (NSA) TERHADAP PENINGKATAN SNR DAN WAKTU
PENCITRAAN PADA MRI |
title_short | ANALISIS PERUBAHAN PARAMETER NUMBER OF SIGNALS
AVERAGED (NSA) TERHADAP PENINGKATAN SNR DAN WAKTU
PENCITRAAN PADA MRI |
title_sort | analisis perubahan parameter number of signals averaged nsa terhadap peningkatan snr dan waktu pencitraan pada mri |
topic | ETD |
work_keys_str_mv | AT dwirochmayanti analisisperubahanparameternumberofsignalsaveragednsaterhadappeningkatansnrdanwaktupencitraanpadamri AT profdrirthomassriwidododea analisisperubahanparameternumberofsignalsaveragednsaterhadappeningkatansnrdanwaktupencitraanpadamri |