Comparison of tensiometer. Thermal conductivity and capacitance sensor measurements of pore water pressure in compacted clay columns

Real-time pore water pressure measurements have been made automatically and continuously with tensiometer (GT), thermal conductivity (TC) and capacitance (MP) sensors in laboratory compacted clay columns. Although GT, TC and MP sensors have been commonly used in many applications, there has rarely...

ver descrição completa

Detalhes bibliográficos
Main Authors: Indrawan, I.G.B, Williams, D.J., Scheuermann, A.
Formato: Artigo
Idioma:English
Publicado em: CRC Press 2014