Comparison of tensiometer. Thermal conductivity and capacitance sensor measurements of pore water pressure in compacted clay columns

Real-time pore water pressure measurements have been made automatically and continuously with tensiometer (GT), thermal conductivity (TC) and capacitance (MP) sensors in laboratory compacted clay columns. Although GT, TC and MP sensors have been commonly used in many applications, there has rarely...

Full description

Bibliographic Details
Main Authors: Indrawan, I.G.B, Williams, D.J., Scheuermann, A.
Format: Article
Language:English
Published: CRC Press 2014
Subjects: