PERHITUNGAN KETAHANAN GEMPA GEDUNG IRJ BLOK III RSU DR SARDJITO BERDASARKAN ASCE 7-10

IRJ Building Block III SARDJITO hospital located in Yogyakarta is categorized as an important facility post earthquake disaster. Indonesian seismic hazard map issued by Ministry of Public Work in 2010 provides information the increase of seismicity level in the region Yogyakarta. Linier Dynamic anal...

Full description

Bibliographic Details
Main Authors: , Y.B. Dhomas Adiwijayanto, , Dr.-Ing. Ir. Djoko Sulistyo
Format: Thesis
Published: [Yogyakarta] : Universitas Gadjah Mada 2012
Subjects:
ETD
Description
Summary:IRJ Building Block III SARDJITO hospital located in Yogyakarta is categorized as an important facility post earthquake disaster. Indonesian seismic hazard map issued by Ministry of Public Work in 2010 provides information the increase of seismicity level in the region Yogyakarta. Linier Dynamic analysis was used for the evaluation, and adopted response spectrum method according to ASCE 7-10. Based on consideration of ductility to be provided by a structural element, the response modification coefficient of intermediate level was taken. From the results of evaluation, the lateral displacement compies with the code. But, on examination of the capacity, it was obtained different dimension from the exsisting building on several element.