PENGARUH PEMAKAIAN PROTESA MAKSILOFASIAL DENGAN DAN TANPA HOLLOW BULB PASCA HEMIMAXILLECTOMY TERHADAP KEJELASAN SUARA

The causative factors of hemimaxillectomy was the existence of malignant or benign tumour at the maxilla base, congenital malformation or trauma. The effect of hemimaxillectomy is the opening space of oral cavity, nasal cavity and sinus, which named defect. To overcome the defect, maxillofacial prot...

Full description

Bibliographic Details
Main Authors: , Susi Wijiati, , Drg. H. Suparyono Saleh, Sp.Pros(K)
Format: Thesis
Published: [Yogyakarta] : Universitas Gadjah Mada 2013
Subjects:
ETD
_version_ 1826046048427048960
author , Susi Wijiati
, Drg. H. Suparyono Saleh, Sp.Pros(K)
author_facet , Susi Wijiati
, Drg. H. Suparyono Saleh, Sp.Pros(K)
author_sort , Susi Wijiati
collection UGM
description The causative factors of hemimaxillectomy was the existence of malignant or benign tumour at the maxilla base, congenital malformation or trauma. The effect of hemimaxillectomy is the opening space of oral cavity, nasal cavity and sinus, which named defect. To overcome the defect, maxillofacial prothesis is needed to restore the function of speech. The purpose of this study was to determine the effect of maxillofacial prosthesis with and without post-hemimaxillectomy hollow bulb on the clarity of the speech sound. Six subject was follow the criteria, with Class II Aramany defect. Speech sound was recorded when using the maxillofacial prothesis with and without hollow bulb, the subjects were ordered to say buy/bobby/puppy, and the sound recorded using cool edit software version 2.0. Data would be analyzed by t test by compairing the average frequence of the sound when used maxilofacial frequence with and without hollow bulb. The result of the t test analysis showed a significant differences between subject that used the maxilofacial prothesis with and without hollow bulb (p<0,05). The conclusion of this study was the use of post hemimaxillectomy maxillofacial prosthesis with a hollow bulb affect the increased the clarity of speech sound.
first_indexed 2024-03-13T22:47:09Z
format Thesis
id oai:generic.eprints.org:118617
institution Universiti Gadjah Mada
last_indexed 2024-03-13T22:47:09Z
publishDate 2013
publisher [Yogyakarta] : Universitas Gadjah Mada
record_format dspace
spelling oai:generic.eprints.org:1186172016-03-04T08:43:44Z https://repository.ugm.ac.id/118617/ PENGARUH PEMAKAIAN PROTESA MAKSILOFASIAL DENGAN DAN TANPA HOLLOW BULB PASCA HEMIMAXILLECTOMY TERHADAP KEJELASAN SUARA , Susi Wijiati , Drg. H. Suparyono Saleh, Sp.Pros(K) ETD The causative factors of hemimaxillectomy was the existence of malignant or benign tumour at the maxilla base, congenital malformation or trauma. The effect of hemimaxillectomy is the opening space of oral cavity, nasal cavity and sinus, which named defect. To overcome the defect, maxillofacial prothesis is needed to restore the function of speech. The purpose of this study was to determine the effect of maxillofacial prosthesis with and without post-hemimaxillectomy hollow bulb on the clarity of the speech sound. Six subject was follow the criteria, with Class II Aramany defect. Speech sound was recorded when using the maxillofacial prothesis with and without hollow bulb, the subjects were ordered to say buy/bobby/puppy, and the sound recorded using cool edit software version 2.0. Data would be analyzed by t test by compairing the average frequence of the sound when used maxilofacial frequence with and without hollow bulb. The result of the t test analysis showed a significant differences between subject that used the maxilofacial prothesis with and without hollow bulb (p<0,05). The conclusion of this study was the use of post hemimaxillectomy maxillofacial prosthesis with a hollow bulb affect the increased the clarity of speech sound. [Yogyakarta] : Universitas Gadjah Mada 2013 Thesis NonPeerReviewed , Susi Wijiati and , Drg. H. Suparyono Saleh, Sp.Pros(K) (2013) PENGARUH PEMAKAIAN PROTESA MAKSILOFASIAL DENGAN DAN TANPA HOLLOW BULB PASCA HEMIMAXILLECTOMY TERHADAP KEJELASAN SUARA. UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=58592
spellingShingle ETD
, Susi Wijiati
, Drg. H. Suparyono Saleh, Sp.Pros(K)
PENGARUH PEMAKAIAN PROTESA MAKSILOFASIAL DENGAN DAN TANPA HOLLOW BULB PASCA HEMIMAXILLECTOMY TERHADAP KEJELASAN SUARA
title PENGARUH PEMAKAIAN PROTESA MAKSILOFASIAL DENGAN DAN TANPA HOLLOW BULB PASCA HEMIMAXILLECTOMY TERHADAP KEJELASAN SUARA
title_full PENGARUH PEMAKAIAN PROTESA MAKSILOFASIAL DENGAN DAN TANPA HOLLOW BULB PASCA HEMIMAXILLECTOMY TERHADAP KEJELASAN SUARA
title_fullStr PENGARUH PEMAKAIAN PROTESA MAKSILOFASIAL DENGAN DAN TANPA HOLLOW BULB PASCA HEMIMAXILLECTOMY TERHADAP KEJELASAN SUARA
title_full_unstemmed PENGARUH PEMAKAIAN PROTESA MAKSILOFASIAL DENGAN DAN TANPA HOLLOW BULB PASCA HEMIMAXILLECTOMY TERHADAP KEJELASAN SUARA
title_short PENGARUH PEMAKAIAN PROTESA MAKSILOFASIAL DENGAN DAN TANPA HOLLOW BULB PASCA HEMIMAXILLECTOMY TERHADAP KEJELASAN SUARA
title_sort pengaruh pemakaian protesa maksilofasial dengan dan tanpa hollow bulb pasca hemimaxillectomy terhadap kejelasan suara
topic ETD
work_keys_str_mv AT susiwijiati pengaruhpemakaianprotesamaksilofasialdengandantanpahollowbulbpascahemimaxillectomyterhadapkejelasansuara
AT drghsuparyonosalehspprosk pengaruhpemakaianprotesamaksilofasialdengandantanpahollowbulbpascahemimaxillectomyterhadapkejelasansuara