PERILAKU SAMBUNGAN BALOK KOLOM INTERIOR TIPE SILANG (+) AKIBAT BEBAN SIKLIK PADA KERANGKA STRUKTUR BANGUNAN BAMBU

Beam column joint is a very important structure element in the building construction design and the weakest part if it is not well-designed. This research is conducted to do a more thorough study about the strength of the beam column joint within a bamboo building structure framework which given a c...

Full description

Bibliographic Details
Main Authors: , Dewi Ayu Setiawati, , Dr.-Ing. Ir. Djoko Sulistyo
Format: Thesis
Published: [Yogyakarta] : Universitas Gadjah Mada 2013
Subjects:
ETD
Description
Summary:Beam column joint is a very important structure element in the building construction design and the weakest part if it is not well-designed. This research is conducted to do a more thorough study about the strength of the beam column joint within a bamboo building structure framework which given a cyclicload, thus the bamboo strength can be optimally utilized. This research also studies about the ductility, stiffness, hysteretic energy, potential, damping ratio also the damage pattern of cross-typed interior beam column joint (+) in a simple building structure framework. In this research, two full-scale, cross-typed interior beam column joint (+) is made and given the same treatment. The specimen was created with the dimension of 3 x 3 m and has been preserved by using gravitation method with borax solution. The bamboo used is a wulung bamboo, with three layer of beam model and double layer of column model. The test object uses a ½� screw as its shear connector and mortar as the filler, which is filled into the space inside the bamboo, only on the joint area. The seismic load approach refers to the ASTM 2126-02a standard. From the test result, B.U.1 specimen shows the average load in yield condition of 4,59 kN and deflection of 76,78 mm, at peak condition the average loads are 7,44 kN and deflection of 135,77 mm, at failure condition the average load are 5,95 kN and deflection of 136,93 mm. B.U.2 specimen shows average load in yield condition of 6,23 kN and deflection of 62,10 mm, at peak condition with the average load of 9,84 kN and deflection of 131,06 mm, and at failure condition with average load of 7,87 kN with deflection of 137,54 mm. Crack/rupture on the specimen starts on the 9thcycle of beam joint area, along with the load increase on each cycle. The elastic stiffness average for specimen B.U.1 and specimen B.U.2 is 0,11 kN/mm for tensile and 0,10 kN/mm for compressive. The average maximum EVDR value of 10,08% shows that the structure behaviour classified into the critical damping, which is below 20%. The joint ductility value obtained was 1,78 for specimen B.U.1 and 2,23 for specimen B.U.2. According to SNI-03-1726-2002, those ductility value classified into partial ductility, while according to FEMA 306, belongs to the medium ductility.