PERBANDINGAN PEMBERIAN RINGERFUNDIN DENGAN RINGER LAKTAT COLOAD (SAAT) ANESTESI SPINAL DALAM MENCEGAH HIPOTENSI PADA PASIEN SEKSIO SESAREA ELEKTIF

Hypotension is the most common complication in spinal anesthesia. One of the prevention effort is made by an administration of coloading crystalloid. This study aims to compare hypotension incidence in the coloading administration of Ringerfundin as an isotonic crystalloid and Lactated Ringer as a h...

Full description

Bibliographic Details
Main Authors: , Orizanov Mahisa, , Dr. IG Ngurah Rai Artika, SpAn, KAKV.
Format: Thesis
Published: [Yogyakarta] : Universitas Gadjah Mada 2013
Subjects:
ETD
_version_ 1826046950070288384
author , Orizanov Mahisa
, Dr. IG Ngurah Rai Artika, SpAn, KAKV.
author_facet , Orizanov Mahisa
, Dr. IG Ngurah Rai Artika, SpAn, KAKV.
author_sort , Orizanov Mahisa
collection UGM
description Hypotension is the most common complication in spinal anesthesia. One of the prevention effort is made by an administration of coloading crystalloid. This study aims to compare hypotension incidence in the coloading administration of Ringerfundin as an isotonic crystalloid and Lactated Ringer as a hypotonic crystalloid. Methods : This study was a double blind randomized controlled trials. Subjects were 82 pregnant women, who undergoing caesarean section with spinal anesthesia at Dr Sardjito Hospital in Yogyakarta, Panembahan Senopati Hospital in Bantul and Sleman Hospital. This study was done following institutional ethical committee approval and obtaining patients written informed consent. Patients who were selected had normal singleton pregnancy, more than 37 weeks gestation, 20-40 years old, BMI 20-30 kg/m2, height more than 145 cm, ASA 1-2. The exclusion criteria included patients with decreased lung compliance, preeclampsia, eclampsia, hypertension. Drop out criteria were total spinal, failed spinal. Subject sampling was conducted in consecutive sampling and block randomly. The patients were divided into two groups, group A (coloading 10 ml/kgbw Lactated Ringer ) and group B (coloading 10 ml/kgbw Ringerfundin). Fluid administration immediately after CSF detection in spinal needle. Fluid boluses for both grups were given via a 18G iv catheter with a fully open control valve and gravity alone providing the driving pressure. Hypotension monitoring was recorded every 2 minutes for the first 10 minutes following spinal. In addition, hypotension (25% decrease in baseline BP or SBP < 90 mmHg) could be treated Ephedrin and additional iv fluid boluses of Lactated Ringer. Results : There were no statistical significant differences (p=0.792) in hypotension incidence between Lactated Ringer and Ringerfundin coload administration. Conclusion : The coloading isotonic solution (Ringerfundin) has the similar effect compared to hypotonic solution (Lactated Ringer) to prevent hypotension in spinal anesthesia during elective caesarean section.
first_indexed 2024-03-13T23:02:08Z
format Thesis
id oai:generic.eprints.org:123064
institution Universiti Gadjah Mada
last_indexed 2024-03-13T23:02:08Z
publishDate 2013
publisher [Yogyakarta] : Universitas Gadjah Mada
record_format dspace
spelling oai:generic.eprints.org:1230642016-03-04T08:41:39Z https://repository.ugm.ac.id/123064/ PERBANDINGAN PEMBERIAN RINGERFUNDIN DENGAN RINGER LAKTAT COLOAD (SAAT) ANESTESI SPINAL DALAM MENCEGAH HIPOTENSI PADA PASIEN SEKSIO SESAREA ELEKTIF , Orizanov Mahisa , Dr. IG Ngurah Rai Artika, SpAn, KAKV. ETD Hypotension is the most common complication in spinal anesthesia. One of the prevention effort is made by an administration of coloading crystalloid. This study aims to compare hypotension incidence in the coloading administration of Ringerfundin as an isotonic crystalloid and Lactated Ringer as a hypotonic crystalloid. Methods : This study was a double blind randomized controlled trials. Subjects were 82 pregnant women, who undergoing caesarean section with spinal anesthesia at Dr Sardjito Hospital in Yogyakarta, Panembahan Senopati Hospital in Bantul and Sleman Hospital. This study was done following institutional ethical committee approval and obtaining patients written informed consent. Patients who were selected had normal singleton pregnancy, more than 37 weeks gestation, 20-40 years old, BMI 20-30 kg/m2, height more than 145 cm, ASA 1-2. The exclusion criteria included patients with decreased lung compliance, preeclampsia, eclampsia, hypertension. Drop out criteria were total spinal, failed spinal. Subject sampling was conducted in consecutive sampling and block randomly. The patients were divided into two groups, group A (coloading 10 ml/kgbw Lactated Ringer ) and group B (coloading 10 ml/kgbw Ringerfundin). Fluid administration immediately after CSF detection in spinal needle. Fluid boluses for both grups were given via a 18G iv catheter with a fully open control valve and gravity alone providing the driving pressure. Hypotension monitoring was recorded every 2 minutes for the first 10 minutes following spinal. In addition, hypotension (25% decrease in baseline BP or SBP < 90 mmHg) could be treated Ephedrin and additional iv fluid boluses of Lactated Ringer. Results : There were no statistical significant differences (p=0.792) in hypotension incidence between Lactated Ringer and Ringerfundin coload administration. Conclusion : The coloading isotonic solution (Ringerfundin) has the similar effect compared to hypotonic solution (Lactated Ringer) to prevent hypotension in spinal anesthesia during elective caesarean section. [Yogyakarta] : Universitas Gadjah Mada 2013 Thesis NonPeerReviewed , Orizanov Mahisa and , Dr. IG Ngurah Rai Artika, SpAn, KAKV. (2013) PERBANDINGAN PEMBERIAN RINGERFUNDIN DENGAN RINGER LAKTAT COLOAD (SAAT) ANESTESI SPINAL DALAM MENCEGAH HIPOTENSI PADA PASIEN SEKSIO SESAREA ELEKTIF. UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=63174
spellingShingle ETD
, Orizanov Mahisa
, Dr. IG Ngurah Rai Artika, SpAn, KAKV.
PERBANDINGAN PEMBERIAN RINGERFUNDIN DENGAN RINGER LAKTAT COLOAD (SAAT) ANESTESI SPINAL DALAM MENCEGAH HIPOTENSI PADA PASIEN SEKSIO SESAREA ELEKTIF
title PERBANDINGAN PEMBERIAN RINGERFUNDIN DENGAN RINGER LAKTAT COLOAD (SAAT) ANESTESI SPINAL DALAM MENCEGAH HIPOTENSI PADA PASIEN SEKSIO SESAREA ELEKTIF
title_full PERBANDINGAN PEMBERIAN RINGERFUNDIN DENGAN RINGER LAKTAT COLOAD (SAAT) ANESTESI SPINAL DALAM MENCEGAH HIPOTENSI PADA PASIEN SEKSIO SESAREA ELEKTIF
title_fullStr PERBANDINGAN PEMBERIAN RINGERFUNDIN DENGAN RINGER LAKTAT COLOAD (SAAT) ANESTESI SPINAL DALAM MENCEGAH HIPOTENSI PADA PASIEN SEKSIO SESAREA ELEKTIF
title_full_unstemmed PERBANDINGAN PEMBERIAN RINGERFUNDIN DENGAN RINGER LAKTAT COLOAD (SAAT) ANESTESI SPINAL DALAM MENCEGAH HIPOTENSI PADA PASIEN SEKSIO SESAREA ELEKTIF
title_short PERBANDINGAN PEMBERIAN RINGERFUNDIN DENGAN RINGER LAKTAT COLOAD (SAAT) ANESTESI SPINAL DALAM MENCEGAH HIPOTENSI PADA PASIEN SEKSIO SESAREA ELEKTIF
title_sort perbandingan pemberian ringerfundin dengan ringer laktat coload saat anestesi spinal dalam mencegah hipotensi pada pasien seksio sesarea elektif
topic ETD
work_keys_str_mv AT orizanovmahisa perbandinganpemberianringerfundindenganringerlaktatcoloadsaatanestesispinaldalammencegahhipotensipadapasienseksiosesareaelektif
AT drigngurahraiartikaspankakv perbandinganpemberianringerfundindenganringerlaktatcoloadsaatanestesispinaldalammencegahhipotensipadapasienseksiosesareaelektif