EKSTRAKSI CIRI SINYAL ELECTROMYOGRAPH STATIS PADA EKSTENSI-FLEKSI TELAPAK TANGAN

Electromyograph (EMG) had a function of detecting the potential existence of electricity that was produced by muscle cells at the time of the contraction muscle and relaksasi. The signal of muscle electricity could be received through the EMG electrode fitting that was placed in the surface of skin...

Full description

Bibliographic Details
Main Authors: , TRIANA RAHMAWATI, , Dr. Indah Soesanti, ST., MT.
Format: Thesis
Published: [Yogyakarta] : Universitas Gadjah Mada 2013
Subjects:
ETD
_version_ 1797033910935224320
author , TRIANA RAHMAWATI
, Dr. Indah Soesanti, ST., MT.
author_facet , TRIANA RAHMAWATI
, Dr. Indah Soesanti, ST., MT.
author_sort , TRIANA RAHMAWATI
collection UGM
description Electromyograph (EMG) had a function of detecting the potential existence of electricity that was produced by muscle cells at the time of the contraction muscle and relaksasi. The signal of muscle electricity could be received through the EMG electrode fitting that was placed in the surface of skin to the muscle that will be taken by his signal data. The system that was produced from EMG could study the muscle signal from the surface of skin when someone carried out the certain movement. So as to be able to be used for the control signal of the system or other equipment. The EMG signal had the characteristics of the quite small amplitude (0 10 mV) and the frequency in range 20 500 Hz. [11]. The feature extractionwas carried out in the time domain by producing the RMS value the amplitude of the EMG signal and the feature extractionwas in the frequency domain used by Fast Fourier Transform (FFT) by counting the Mean Power Frequency value (MPF) and the Frequency Median (MDF) the EMG signal. From results of the feature extraction was received by the MPF value, MDF and RMS to the muscle extensor carpi radialis longus, flexor carpi ulnaris and flexor carpi radialis for the HO condition, HC, WF and WE. Nilai MPF lowered 56.507 Hz and the MPF value highest 209.67 Hz. The MDF value lowered 39.512 Hz and the MDF value highest 152.28 Hz. The RMS value the lowered amplitude 0.10681 mV and the RMS value highest 0.91393 mV.
first_indexed 2024-03-13T23:02:22Z
format Thesis
id oai:generic.eprints.org:123144
institution Universiti Gadjah Mada
last_indexed 2024-03-13T23:02:22Z
publishDate 2013
publisher [Yogyakarta] : Universitas Gadjah Mada
record_format dspace
spelling oai:generic.eprints.org:1231442016-03-04T08:43:57Z https://repository.ugm.ac.id/123144/ EKSTRAKSI CIRI SINYAL ELECTROMYOGRAPH STATIS PADA EKSTENSI-FLEKSI TELAPAK TANGAN , TRIANA RAHMAWATI , Dr. Indah Soesanti, ST., MT. ETD Electromyograph (EMG) had a function of detecting the potential existence of electricity that was produced by muscle cells at the time of the contraction muscle and relaksasi. The signal of muscle electricity could be received through the EMG electrode fitting that was placed in the surface of skin to the muscle that will be taken by his signal data. The system that was produced from EMG could study the muscle signal from the surface of skin when someone carried out the certain movement. So as to be able to be used for the control signal of the system or other equipment. The EMG signal had the characteristics of the quite small amplitude (0 10 mV) and the frequency in range 20 500 Hz. [11]. The feature extractionwas carried out in the time domain by producing the RMS value the amplitude of the EMG signal and the feature extractionwas in the frequency domain used by Fast Fourier Transform (FFT) by counting the Mean Power Frequency value (MPF) and the Frequency Median (MDF) the EMG signal. From results of the feature extraction was received by the MPF value, MDF and RMS to the muscle extensor carpi radialis longus, flexor carpi ulnaris and flexor carpi radialis for the HO condition, HC, WF and WE. Nilai MPF lowered 56.507 Hz and the MPF value highest 209.67 Hz. The MDF value lowered 39.512 Hz and the MDF value highest 152.28 Hz. The RMS value the lowered amplitude 0.10681 mV and the RMS value highest 0.91393 mV. [Yogyakarta] : Universitas Gadjah Mada 2013 Thesis NonPeerReviewed , TRIANA RAHMAWATI and , Dr. Indah Soesanti, ST., MT. (2013) EKSTRAKSI CIRI SINYAL ELECTROMYOGRAPH STATIS PADA EKSTENSI-FLEKSI TELAPAK TANGAN. UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=63255
spellingShingle ETD
, TRIANA RAHMAWATI
, Dr. Indah Soesanti, ST., MT.
EKSTRAKSI CIRI SINYAL ELECTROMYOGRAPH STATIS PADA EKSTENSI-FLEKSI TELAPAK TANGAN
title EKSTRAKSI CIRI SINYAL ELECTROMYOGRAPH STATIS PADA EKSTENSI-FLEKSI TELAPAK TANGAN
title_full EKSTRAKSI CIRI SINYAL ELECTROMYOGRAPH STATIS PADA EKSTENSI-FLEKSI TELAPAK TANGAN
title_fullStr EKSTRAKSI CIRI SINYAL ELECTROMYOGRAPH STATIS PADA EKSTENSI-FLEKSI TELAPAK TANGAN
title_full_unstemmed EKSTRAKSI CIRI SINYAL ELECTROMYOGRAPH STATIS PADA EKSTENSI-FLEKSI TELAPAK TANGAN
title_short EKSTRAKSI CIRI SINYAL ELECTROMYOGRAPH STATIS PADA EKSTENSI-FLEKSI TELAPAK TANGAN
title_sort ekstraksi ciri sinyal electromyograph statis pada ekstensi fleksi telapak tangan
topic ETD
work_keys_str_mv AT trianarahmawati ekstraksicirisinyalelectromyographstatispadaekstensifleksitelapaktangan
AT drindahsoesantistmt ekstraksicirisinyalelectromyographstatispadaekstensifleksitelapaktangan