PERBEDAAN LAXITY PALPEBRA INFERIOR SEBELUM DAN SESUDAH PENGGUNAAN SPEKULUM BERKUNCI DAN SPEKULUM TIDAK BERKUNCI PADA OPERASI FAKOEMULSIFIKASI

Purpose: To compare the after effect of two different eyelid speculum based on inferior eyelid laxity after phacoemulsification procedure Methods : This is a prospective, consecutive, and quasi experimental design. All senile cataract patients (75 patients) from February 2013 until July 2013 in �D...

Full description

Bibliographic Details
Main Authors: , Danang Dwinaryono, , Prof.dr.Wasisdi Gunawan, SpM(K)
Format: Thesis
Published: [Yogyakarta] : Universitas Gadjah Mada 2013
Subjects:
ETD
_version_ 1797034020456890368
author , Danang Dwinaryono
, Prof.dr.Wasisdi Gunawan, SpM(K)
author_facet , Danang Dwinaryono
, Prof.dr.Wasisdi Gunawan, SpM(K)
author_sort , Danang Dwinaryono
collection UGM
description Purpose: To compare the after effect of two different eyelid speculum based on inferior eyelid laxity after phacoemulsification procedure Methods : This is a prospective, consecutive, and quasi experimental design. All senile cataract patients (75 patients) from February 2013 until July 2013 in �Dr. Yap� Eye Hospital was held a phacoemulsification procedure. Some examinations such as pinch test, lateral distraction test, snap back test, and then Schirmer test were performed. Each of them was performed an eyelid fissure measurement before and at the operation room. Each subject went a parabulbar injection and Hoonan balloon tamponade as high as 30 mmHg, and the duration of phacoemulsification procedure were recorded. The phacoemulsification procedure used solidblade eyelid speculum and wire speculum. In one week and four week after that procedure, a remeasurement of pinch test, lateral distraction test, snap back test, Schirmer test and eyelid pissure were recorded again. All measurement data was processed using independent sample ttest. Results : There were no mean different according to basic characteristic between two groups except in the first examination of pinch test (p=0,001). Mean differentiation in eyelid speculum with a key according to pinch test was7,76+1,36 (p=0,012) and lateral distraction test was2,08+0,71 (p=0,017) whereas in group eyelid speculum without key according to pinch test was 6,35+0,89 (p=0,000), but there was no different mean according to lateral distraction test (p=0,183) respectively. Conclusion: Whether solid-blade or wire speculum in both groups revealed an extent of inferior eyelid laxity based on pinch test before and four weeks after surgery. Eyelid speculum with key has 1.02 times causing extention of laxity
first_indexed 2024-03-13T23:04:27Z
format Thesis
id oai:generic.eprints.org:123679
institution Universiti Gadjah Mada
last_indexed 2024-03-13T23:04:27Z
publishDate 2013
publisher [Yogyakarta] : Universitas Gadjah Mada
record_format dspace
spelling oai:generic.eprints.org:1236792016-03-04T08:31:42Z https://repository.ugm.ac.id/123679/ PERBEDAAN LAXITY PALPEBRA INFERIOR SEBELUM DAN SESUDAH PENGGUNAAN SPEKULUM BERKUNCI DAN SPEKULUM TIDAK BERKUNCI PADA OPERASI FAKOEMULSIFIKASI , Danang Dwinaryono , Prof.dr.Wasisdi Gunawan, SpM(K) ETD Purpose: To compare the after effect of two different eyelid speculum based on inferior eyelid laxity after phacoemulsification procedure Methods : This is a prospective, consecutive, and quasi experimental design. All senile cataract patients (75 patients) from February 2013 until July 2013 in �Dr. Yap� Eye Hospital was held a phacoemulsification procedure. Some examinations such as pinch test, lateral distraction test, snap back test, and then Schirmer test were performed. Each of them was performed an eyelid fissure measurement before and at the operation room. Each subject went a parabulbar injection and Hoonan balloon tamponade as high as 30 mmHg, and the duration of phacoemulsification procedure were recorded. The phacoemulsification procedure used solidblade eyelid speculum and wire speculum. In one week and four week after that procedure, a remeasurement of pinch test, lateral distraction test, snap back test, Schirmer test and eyelid pissure were recorded again. All measurement data was processed using independent sample ttest. Results : There were no mean different according to basic characteristic between two groups except in the first examination of pinch test (p=0,001). Mean differentiation in eyelid speculum with a key according to pinch test was7,76+1,36 (p=0,012) and lateral distraction test was2,08+0,71 (p=0,017) whereas in group eyelid speculum without key according to pinch test was 6,35+0,89 (p=0,000), but there was no different mean according to lateral distraction test (p=0,183) respectively. Conclusion: Whether solid-blade or wire speculum in both groups revealed an extent of inferior eyelid laxity based on pinch test before and four weeks after surgery. Eyelid speculum with key has 1.02 times causing extention of laxity [Yogyakarta] : Universitas Gadjah Mada 2013 Thesis NonPeerReviewed , Danang Dwinaryono and , Prof.dr.Wasisdi Gunawan, SpM(K) (2013) PERBEDAAN LAXITY PALPEBRA INFERIOR SEBELUM DAN SESUDAH PENGGUNAAN SPEKULUM BERKUNCI DAN SPEKULUM TIDAK BERKUNCI PADA OPERASI FAKOEMULSIFIKASI. UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=63793
spellingShingle ETD
, Danang Dwinaryono
, Prof.dr.Wasisdi Gunawan, SpM(K)
PERBEDAAN LAXITY PALPEBRA INFERIOR SEBELUM DAN SESUDAH PENGGUNAAN SPEKULUM BERKUNCI DAN SPEKULUM TIDAK BERKUNCI PADA OPERASI FAKOEMULSIFIKASI
title PERBEDAAN LAXITY PALPEBRA INFERIOR SEBELUM DAN SESUDAH PENGGUNAAN SPEKULUM BERKUNCI DAN SPEKULUM TIDAK BERKUNCI PADA OPERASI FAKOEMULSIFIKASI
title_full PERBEDAAN LAXITY PALPEBRA INFERIOR SEBELUM DAN SESUDAH PENGGUNAAN SPEKULUM BERKUNCI DAN SPEKULUM TIDAK BERKUNCI PADA OPERASI FAKOEMULSIFIKASI
title_fullStr PERBEDAAN LAXITY PALPEBRA INFERIOR SEBELUM DAN SESUDAH PENGGUNAAN SPEKULUM BERKUNCI DAN SPEKULUM TIDAK BERKUNCI PADA OPERASI FAKOEMULSIFIKASI
title_full_unstemmed PERBEDAAN LAXITY PALPEBRA INFERIOR SEBELUM DAN SESUDAH PENGGUNAAN SPEKULUM BERKUNCI DAN SPEKULUM TIDAK BERKUNCI PADA OPERASI FAKOEMULSIFIKASI
title_short PERBEDAAN LAXITY PALPEBRA INFERIOR SEBELUM DAN SESUDAH PENGGUNAAN SPEKULUM BERKUNCI DAN SPEKULUM TIDAK BERKUNCI PADA OPERASI FAKOEMULSIFIKASI
title_sort perbedaan laxity palpebra inferior sebelum dan sesudah penggunaan spekulum berkunci dan spekulum tidak berkunci pada operasi fakoemulsifikasi
topic ETD
work_keys_str_mv AT danangdwinaryono perbedaanlaxitypalpebrainferiorsebelumdansesudahpenggunaanspekulumberkuncidanspekulumtidakberkuncipadaoperasifakoemulsifikasi
AT profdrwasisdigunawanspmk perbedaanlaxitypalpebrainferiorsebelumdansesudahpenggunaanspekulumberkuncidanspekulumtidakberkuncipadaoperasifakoemulsifikasi