PENGARUH KETAHANAN ISOLATOR KACA YANG DISUSUN SERI TERHADAP NILAI ARUS BOCOR DAN CORONA INCEPTION VOLTAGE

With the increasing demand for electrical energy, electrical energy distribution is expected to take place in a reliable and efficient. One solution is by applying a high voltage on the transmission line, but with the high voltage also increases the possibility of leakage current and corona. Ther...

Full description

Bibliographic Details
Main Authors: PUTERI, BRIGITTA DIAN, Haryono, T
Format: Thesis
Published: [Yogyakarta] : Universitas Gadjah Mada 2013
Subjects:
_version_ 1826047188820557824
author PUTERI, BRIGITTA DIAN
Haryono, T
author_facet PUTERI, BRIGITTA DIAN
Haryono, T
author_sort PUTERI, BRIGITTA DIAN
collection UGM
description With the increasing demand for electrical energy, electrical energy distribution is expected to take place in a reliable and efficient. One solution is by applying a high voltage on the transmission line, but with the high voltage also increases the possibility of leakage current and corona. Therefore, it needs proper insulation system to prevent leakage losses and corona so the losses such as corona and leakage current can be minimized. This study aimed to determine the effect of chopped glass insulators are installed in series to the amount of leakage current that occurs at a temperature, humidity, and conditions vary insulator. As well to see the effect of adding chopped glass insulators and the time series of the corona inception voltage. Testing is done by applying an alternating voltage (AC) at 10 kV to 120 kV on each count of the glass insulator series of 1 to 5 pieces. Corona phenomena observed by putting the camera in close to record sound insulator corona happens. Then processed the sound of corona to see the waveform, amplitude noise, time of the corona when its happened. The results showed that the count of glass insulators mounted series resistance affects the insulator in restraining leakage current and corona. Corona noise generated will be stronger along with increasing the applied voltage seen from the greater amplitude. By adding chopped glass insulator, then the corona will occur at a higher voltage and occur at longer time. Performance of insulator is affected by temperature, humidity environment around the insulator, and the condition of pollutants on insulators.
first_indexed 2024-03-13T23:06:25Z
format Thesis
id oai:generic.eprints.org:124253
institution Universiti Gadjah Mada
last_indexed 2024-03-13T23:06:25Z
publishDate 2013
publisher [Yogyakarta] : Universitas Gadjah Mada
record_format dspace
spelling oai:generic.eprints.org:1242532020-09-16T04:38:04Z https://repository.ugm.ac.id/124253/ PENGARUH KETAHANAN ISOLATOR KACA YANG DISUSUN SERI TERHADAP NILAI ARUS BOCOR DAN CORONA INCEPTION VOLTAGE PUTERI, BRIGITTA DIAN Haryono, T Electrical and Electronic Engineering With the increasing demand for electrical energy, electrical energy distribution is expected to take place in a reliable and efficient. One solution is by applying a high voltage on the transmission line, but with the high voltage also increases the possibility of leakage current and corona. Therefore, it needs proper insulation system to prevent leakage losses and corona so the losses such as corona and leakage current can be minimized. This study aimed to determine the effect of chopped glass insulators are installed in series to the amount of leakage current that occurs at a temperature, humidity, and conditions vary insulator. As well to see the effect of adding chopped glass insulators and the time series of the corona inception voltage. Testing is done by applying an alternating voltage (AC) at 10 kV to 120 kV on each count of the glass insulator series of 1 to 5 pieces. Corona phenomena observed by putting the camera in close to record sound insulator corona happens. Then processed the sound of corona to see the waveform, amplitude noise, time of the corona when its happened. The results showed that the count of glass insulators mounted series resistance affects the insulator in restraining leakage current and corona. Corona noise generated will be stronger along with increasing the applied voltage seen from the greater amplitude. By adding chopped glass insulator, then the corona will occur at a higher voltage and occur at longer time. Performance of insulator is affected by temperature, humidity environment around the insulator, and the condition of pollutants on insulators. [Yogyakarta] : Universitas Gadjah Mada 2013 Thesis NonPeerReviewed PUTERI, BRIGITTA DIAN and Haryono, T (2013) PENGARUH KETAHANAN ISOLATOR KACA YANG DISUSUN SERI TERHADAP NILAI ARUS BOCOR DAN CORONA INCEPTION VOLTAGE. Masters thesis, Universitas Gadjah Mada. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=64373
spellingShingle Electrical and Electronic Engineering
PUTERI, BRIGITTA DIAN
Haryono, T
PENGARUH KETAHANAN ISOLATOR KACA YANG DISUSUN SERI TERHADAP NILAI ARUS BOCOR DAN CORONA INCEPTION VOLTAGE
title PENGARUH KETAHANAN ISOLATOR KACA YANG DISUSUN SERI TERHADAP NILAI ARUS BOCOR DAN CORONA INCEPTION VOLTAGE
title_full PENGARUH KETAHANAN ISOLATOR KACA YANG DISUSUN SERI TERHADAP NILAI ARUS BOCOR DAN CORONA INCEPTION VOLTAGE
title_fullStr PENGARUH KETAHANAN ISOLATOR KACA YANG DISUSUN SERI TERHADAP NILAI ARUS BOCOR DAN CORONA INCEPTION VOLTAGE
title_full_unstemmed PENGARUH KETAHANAN ISOLATOR KACA YANG DISUSUN SERI TERHADAP NILAI ARUS BOCOR DAN CORONA INCEPTION VOLTAGE
title_short PENGARUH KETAHANAN ISOLATOR KACA YANG DISUSUN SERI TERHADAP NILAI ARUS BOCOR DAN CORONA INCEPTION VOLTAGE
title_sort pengaruh ketahanan isolator kaca yang disusun seri terhadap nilai arus bocor dan corona inception voltage
topic Electrical and Electronic Engineering
work_keys_str_mv AT puteribrigittadian pengaruhketahananisolatorkacayangdisusunseriterhadapnilaiarusbocordancoronainceptionvoltage
AT haryonot pengaruhketahananisolatorkacayangdisusunseriterhadapnilaiarusbocordancoronainceptionvoltage