PERBANDINGAN VIABILITAS EMBRIO PASCA PENGHANGATAN PADA PROSEDUR VITRIFIKASI DENGAN MENGGUNAKAN OPEN-PULLED STRAW (OPS) DAN GAMA SLEEVED-CRYOLOOP 0,1 µl SEBAGAI DEVICE (MODEL MENCIT)

BACKGROUND : One of the influencing factors in vitrification procedure is the embryo device which is related to cryoprotectant toxicity. The success rate of vitrification procedure can be assessed by viability of vitrified embryo upon warming process, with the development of embryo preimplantation a...

Full description

Bibliographic Details
Main Authors: , VEGHA NEDYA, , Prof. dr. Djaswadi Dasuki, MPH, PhD, SpOG(K)
Format: Thesis
Published: [Yogyakarta] : Universitas Gadjah Mada 2014
Subjects:
ETD
_version_ 1826048015195963392
author , VEGHA NEDYA
, Prof. dr. Djaswadi Dasuki, MPH, PhD, SpOG(K)
author_facet , VEGHA NEDYA
, Prof. dr. Djaswadi Dasuki, MPH, PhD, SpOG(K)
author_sort , VEGHA NEDYA
collection UGM
description BACKGROUND : One of the influencing factors in vitrification procedure is the embryo device which is related to cryoprotectant toxicity. The success rate of vitrification procedure can be assessed by viability of vitrified embryo upon warming process, with the development of embryo preimplantation as the indicator. OBJECTIVE : To investigate the influence of Open-Pulled Straw (OPS) and Gama Sleeved-Cryoloop 0.1 μl devices in vitrification procedure on the viability of embryo. RESULTS : 133 eight-cell stage embryos were treated as subjects of the experiment. The analysis using Chi-square test showed result of p-value 0.843 (retrieved)
first_indexed 2024-03-13T23:20:45Z
format Thesis
id oai:generic.eprints.org:128378
institution Universiti Gadjah Mada
last_indexed 2024-03-13T23:20:45Z
publishDate 2014
publisher [Yogyakarta] : Universitas Gadjah Mada
record_format dspace
spelling oai:generic.eprints.org:1283782016-03-04T08:16:21Z https://repository.ugm.ac.id/128378/ PERBANDINGAN VIABILITAS EMBRIO PASCA PENGHANGATAN PADA PROSEDUR VITRIFIKASI DENGAN MENGGUNAKAN OPEN-PULLED STRAW (OPS) DAN GAMA SLEEVED-CRYOLOOP 0,1 µl SEBAGAI DEVICE (MODEL MENCIT) , VEGHA NEDYA , Prof. dr. Djaswadi Dasuki, MPH, PhD, SpOG(K) ETD BACKGROUND : One of the influencing factors in vitrification procedure is the embryo device which is related to cryoprotectant toxicity. The success rate of vitrification procedure can be assessed by viability of vitrified embryo upon warming process, with the development of embryo preimplantation as the indicator. OBJECTIVE : To investigate the influence of Open-Pulled Straw (OPS) and Gama Sleeved-Cryoloop 0.1 μl devices in vitrification procedure on the viability of embryo. RESULTS : 133 eight-cell stage embryos were treated as subjects of the experiment. The analysis using Chi-square test showed result of p-value 0.843 (retrieved) [Yogyakarta] : Universitas Gadjah Mada 2014 Thesis NonPeerReviewed , VEGHA NEDYA and , Prof. dr. Djaswadi Dasuki, MPH, PhD, SpOG(K) (2014) PERBANDINGAN VIABILITAS EMBRIO PASCA PENGHANGATAN PADA PROSEDUR VITRIFIKASI DENGAN MENGGUNAKAN OPEN-PULLED STRAW (OPS) DAN GAMA SLEEVED-CRYOLOOP 0,1 µl SEBAGAI DEVICE (MODEL MENCIT). UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=68720
spellingShingle ETD
, VEGHA NEDYA
, Prof. dr. Djaswadi Dasuki, MPH, PhD, SpOG(K)
PERBANDINGAN VIABILITAS EMBRIO PASCA PENGHANGATAN PADA PROSEDUR VITRIFIKASI DENGAN MENGGUNAKAN OPEN-PULLED STRAW (OPS) DAN GAMA SLEEVED-CRYOLOOP 0,1 µl SEBAGAI DEVICE (MODEL MENCIT)
title PERBANDINGAN VIABILITAS EMBRIO PASCA PENGHANGATAN PADA PROSEDUR VITRIFIKASI DENGAN MENGGUNAKAN OPEN-PULLED STRAW (OPS) DAN GAMA SLEEVED-CRYOLOOP 0,1 µl SEBAGAI DEVICE (MODEL MENCIT)
title_full PERBANDINGAN VIABILITAS EMBRIO PASCA PENGHANGATAN PADA PROSEDUR VITRIFIKASI DENGAN MENGGUNAKAN OPEN-PULLED STRAW (OPS) DAN GAMA SLEEVED-CRYOLOOP 0,1 µl SEBAGAI DEVICE (MODEL MENCIT)
title_fullStr PERBANDINGAN VIABILITAS EMBRIO PASCA PENGHANGATAN PADA PROSEDUR VITRIFIKASI DENGAN MENGGUNAKAN OPEN-PULLED STRAW (OPS) DAN GAMA SLEEVED-CRYOLOOP 0,1 µl SEBAGAI DEVICE (MODEL MENCIT)
title_full_unstemmed PERBANDINGAN VIABILITAS EMBRIO PASCA PENGHANGATAN PADA PROSEDUR VITRIFIKASI DENGAN MENGGUNAKAN OPEN-PULLED STRAW (OPS) DAN GAMA SLEEVED-CRYOLOOP 0,1 µl SEBAGAI DEVICE (MODEL MENCIT)
title_short PERBANDINGAN VIABILITAS EMBRIO PASCA PENGHANGATAN PADA PROSEDUR VITRIFIKASI DENGAN MENGGUNAKAN OPEN-PULLED STRAW (OPS) DAN GAMA SLEEVED-CRYOLOOP 0,1 µl SEBAGAI DEVICE (MODEL MENCIT)
title_sort perbandingan viabilitas embrio pasca penghangatan pada prosedur vitrifikasi dengan menggunakan open pulled straw ops dan gama sleeved cryoloop 0 1 aµl sebagai device model mencit
topic ETD
work_keys_str_mv AT veghanedya perbandinganviabilitasembriopascapenghangatanpadaprosedurvitrifikasidenganmenggunakanopenpulledstrawopsdangamasleevedcryoloop01aμlsebagaidevicemodelmencit
AT profdrdjaswadidasukimphphdspogk perbandinganviabilitasembriopascapenghangatanpadaprosedurvitrifikasidenganmenggunakanopenpulledstrawopsdangamasleevedcryoloop01aμlsebagaidevicemodelmencit