ON THE ACCURACY OF WIRE-MESH SENSOR IN DEPENDENCE OF BUBBLE SIZES AND LIQUID FLOW RATES
An experimental study to assess the accuracy of wire-mesh sensor in dependence of bubble sizes and flow rates has been performed in a 50 mm x 50 mm transparent rectangular channel. The liquid superficial velocities were ranging from 0 m/s up to 0.62 m/s with the obtained bubble size ranging from 3 m...