KENYAMANAN TERMAL RUANG LUAR DI KORIDOR JALAN TUGU-KRATON KOTA YOGYAKARTA

The research of outdoor thermal comfort in Tugu-Kraton Street Corridor Yogyakarta City is important to do. Urban heat island makes thermal comfort declined. Outdoor is a place often used carrying out social interaction. Outdoor thermal comfort is depended on its enclosure. Study has objectives to me...

Full description

Bibliographic Details
Main Authors: , ARDINA PUTRI RAHTAMA, , M. Sani Roychansyah, ST., M.Eng., D.Eng.
Format: Thesis
Published: [Yogyakarta] : Universitas Gadjah Mada 2014
Subjects:
ETD
_version_ 1826048202381459456
author , ARDINA PUTRI RAHTAMA
, M. Sani Roychansyah, ST., M.Eng., D.Eng.
author_facet , ARDINA PUTRI RAHTAMA
, M. Sani Roychansyah, ST., M.Eng., D.Eng.
author_sort , ARDINA PUTRI RAHTAMA
collection UGM
description The research of outdoor thermal comfort in Tugu-Kraton Street Corridor Yogyakarta City is important to do. Urban heat island makes thermal comfort declined. Outdoor is a place often used carrying out social interaction. Outdoor thermal comfort is depended on its enclosure. Study has objectives to measure thermal comfort degree and identify its factors. In addition, study also identifies enclosure�s influence towards outdoor thermal comfort. Study uses a mixed deductive method. Quantitative analysis is used to measure thermal comfort. Qualitative analysis is used to relate enclosure�s influence to microclimate condition of the corridor. Study got 256 respondents who have been doing activity in Tugu-Kraton Street Corridor. Interpretation of microclimate data and respondent�s characteristic was done in the same time. The result of study indicates that Tugu-Kraton Street Corridor isn�t comfortable. It is indicated by PET value 37,96°C. PET value shows outdoor thermal comfort standard in Tugu-Kraton Street Corridor at person in the age of 35 years old, 57 kg in weight, and 170 cm in height when he/she is doing activity as big as 1,1 met with clothes 0,52 clo, air temperature 31°C, mean radiant temperature 39°C, solar radiation 51,11 W/m2, air humidity 57,47%RH and wind velocity 0,11 m/s. Youngster prefer colder microclimate than children and old people do. Thermal comfort in Tugu-Kraton Street Corridor is mostly influenced by air temperature, air humidity, and wind velocity. Comfortable outdoor tends to have bright colored buildings, wide setback, a lot of wide crown trees, paved floor, a lot of street furniture, and closed sky view factor.
first_indexed 2024-03-13T23:24:27Z
format Thesis
id oai:generic.eprints.org:129325
institution Universiti Gadjah Mada
last_indexed 2024-03-13T23:24:27Z
publishDate 2014
publisher [Yogyakarta] : Universitas Gadjah Mada
record_format dspace
spelling oai:generic.eprints.org:1293252016-03-04T07:52:28Z https://repository.ugm.ac.id/129325/ KENYAMANAN TERMAL RUANG LUAR DI KORIDOR JALAN TUGU-KRATON KOTA YOGYAKARTA , ARDINA PUTRI RAHTAMA , M. Sani Roychansyah, ST., M.Eng., D.Eng. ETD The research of outdoor thermal comfort in Tugu-Kraton Street Corridor Yogyakarta City is important to do. Urban heat island makes thermal comfort declined. Outdoor is a place often used carrying out social interaction. Outdoor thermal comfort is depended on its enclosure. Study has objectives to measure thermal comfort degree and identify its factors. In addition, study also identifies enclosure�s influence towards outdoor thermal comfort. Study uses a mixed deductive method. Quantitative analysis is used to measure thermal comfort. Qualitative analysis is used to relate enclosure�s influence to microclimate condition of the corridor. Study got 256 respondents who have been doing activity in Tugu-Kraton Street Corridor. Interpretation of microclimate data and respondent�s characteristic was done in the same time. The result of study indicates that Tugu-Kraton Street Corridor isn�t comfortable. It is indicated by PET value 37,96°C. PET value shows outdoor thermal comfort standard in Tugu-Kraton Street Corridor at person in the age of 35 years old, 57 kg in weight, and 170 cm in height when he/she is doing activity as big as 1,1 met with clothes 0,52 clo, air temperature 31°C, mean radiant temperature 39°C, solar radiation 51,11 W/m2, air humidity 57,47%RH and wind velocity 0,11 m/s. Youngster prefer colder microclimate than children and old people do. Thermal comfort in Tugu-Kraton Street Corridor is mostly influenced by air temperature, air humidity, and wind velocity. Comfortable outdoor tends to have bright colored buildings, wide setback, a lot of wide crown trees, paved floor, a lot of street furniture, and closed sky view factor. [Yogyakarta] : Universitas Gadjah Mada 2014 Thesis NonPeerReviewed , ARDINA PUTRI RAHTAMA and , M. Sani Roychansyah, ST., M.Eng., D.Eng. (2014) KENYAMANAN TERMAL RUANG LUAR DI KORIDOR JALAN TUGU-KRATON KOTA YOGYAKARTA. UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=69715
spellingShingle ETD
, ARDINA PUTRI RAHTAMA
, M. Sani Roychansyah, ST., M.Eng., D.Eng.
KENYAMANAN TERMAL RUANG LUAR DI KORIDOR JALAN TUGU-KRATON KOTA YOGYAKARTA
title KENYAMANAN TERMAL RUANG LUAR DI KORIDOR JALAN TUGU-KRATON KOTA YOGYAKARTA
title_full KENYAMANAN TERMAL RUANG LUAR DI KORIDOR JALAN TUGU-KRATON KOTA YOGYAKARTA
title_fullStr KENYAMANAN TERMAL RUANG LUAR DI KORIDOR JALAN TUGU-KRATON KOTA YOGYAKARTA
title_full_unstemmed KENYAMANAN TERMAL RUANG LUAR DI KORIDOR JALAN TUGU-KRATON KOTA YOGYAKARTA
title_short KENYAMANAN TERMAL RUANG LUAR DI KORIDOR JALAN TUGU-KRATON KOTA YOGYAKARTA
title_sort kenyamanan termal ruang luar di koridor jalan tugu kraton kota yogyakarta
topic ETD
work_keys_str_mv AT ardinaputrirahtama kenyamanantermalruangluardikoridorjalantugukratonkotayogyakarta
AT msaniroychansyahstmengdeng kenyamanantermalruangluardikoridorjalantugukratonkotayogyakarta