KEKUATAN SAMBUNGAN BAMBU DENGAN ALAT SAMBUNG BAUT, IJUK, DAN FIBRE-REINFORCED PLASTIC

Some of the research by previous studies are the bamboo connection using bolts and steel knot plates with wood or mortar filler. Those researches have some shortcomings, for example not economical, complicated process, and too heavy due to filling materials inside the connections. Therefore, this re...

Full description

Bibliographic Details
Main Authors: , VIKI ANDRIANI, , Ali Awaludin, S.T., M.Eng., Ph.D.
Format: Thesis
Published: [Yogyakarta] : Universitas Gadjah Mada 2014
Subjects:
ETD
_version_ 1797035239244038144
author , VIKI ANDRIANI
, Ali Awaludin, S.T., M.Eng., Ph.D.
author_facet , VIKI ANDRIANI
, Ali Awaludin, S.T., M.Eng., Ph.D.
author_sort , VIKI ANDRIANI
collection UGM
description Some of the research by previous studies are the bamboo connection using bolts and steel knot plates with wood or mortar filler. Those researches have some shortcomings, for example not economical, complicated process, and too heavy due to filling materials inside the connections. Therefore, this research proposes a new kind of bamboo connection using Fibre-Reinforced Plastic. This research uses double-shear configuration connection. The bamboo being use in the test is bamboo wulung (Gigantochloa atroviolacea) with some connection variations which are bolts, natural fiber ijuk, and Fibre-Reinforced Plastic. From those connection variations, this test was being conducted towards 6 (six) connections models: aligned bolt fiber connection, aligned bolt fiber and natural fiber ijuk connection, aligned FRP fiber connection, aligned FRP fiber and bolt connection, perpendicular bolt fiber connection, perpendicular FRP fiber and bolt connection. This test was loaded with monotonic quasi-static load. From the test results obtained the lowest connection strength on the model using a bolt connection with the result is 8.73 kN and obtained the highest connection strength on the model of FRP fibers parallel connection with the results is 43.73 kN. Then with the addition of FRP, the results show a significant increase of joint strength and stiffness, reaching an increase of ± 4-5 times compared to other connection models. Fibre-Reinforced Plastic gives an positive impact to the connection by postponing the splitting failure of the connection which is at the collapse mechanism.
first_indexed 2024-03-13T23:26:41Z
format Thesis
id oai:generic.eprints.org:129742
institution Universiti Gadjah Mada
last_indexed 2024-03-13T23:26:41Z
publishDate 2014
publisher [Yogyakarta] : Universitas Gadjah Mada
record_format dspace
spelling oai:generic.eprints.org:1297422016-03-04T08:16:30Z https://repository.ugm.ac.id/129742/ KEKUATAN SAMBUNGAN BAMBU DENGAN ALAT SAMBUNG BAUT, IJUK, DAN FIBRE-REINFORCED PLASTIC , VIKI ANDRIANI , Ali Awaludin, S.T., M.Eng., Ph.D. ETD Some of the research by previous studies are the bamboo connection using bolts and steel knot plates with wood or mortar filler. Those researches have some shortcomings, for example not economical, complicated process, and too heavy due to filling materials inside the connections. Therefore, this research proposes a new kind of bamboo connection using Fibre-Reinforced Plastic. This research uses double-shear configuration connection. The bamboo being use in the test is bamboo wulung (Gigantochloa atroviolacea) with some connection variations which are bolts, natural fiber ijuk, and Fibre-Reinforced Plastic. From those connection variations, this test was being conducted towards 6 (six) connections models: aligned bolt fiber connection, aligned bolt fiber and natural fiber ijuk connection, aligned FRP fiber connection, aligned FRP fiber and bolt connection, perpendicular bolt fiber connection, perpendicular FRP fiber and bolt connection. This test was loaded with monotonic quasi-static load. From the test results obtained the lowest connection strength on the model using a bolt connection with the result is 8.73 kN and obtained the highest connection strength on the model of FRP fibers parallel connection with the results is 43.73 kN. Then with the addition of FRP, the results show a significant increase of joint strength and stiffness, reaching an increase of ± 4-5 times compared to other connection models. Fibre-Reinforced Plastic gives an positive impact to the connection by postponing the splitting failure of the connection which is at the collapse mechanism. [Yogyakarta] : Universitas Gadjah Mada 2014 Thesis NonPeerReviewed , VIKI ANDRIANI and , Ali Awaludin, S.T., M.Eng., Ph.D. (2014) KEKUATAN SAMBUNGAN BAMBU DENGAN ALAT SAMBUNG BAUT, IJUK, DAN FIBRE-REINFORCED PLASTIC. UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=70139
spellingShingle ETD
, VIKI ANDRIANI
, Ali Awaludin, S.T., M.Eng., Ph.D.
KEKUATAN SAMBUNGAN BAMBU DENGAN ALAT SAMBUNG BAUT, IJUK, DAN FIBRE-REINFORCED PLASTIC
title KEKUATAN SAMBUNGAN BAMBU DENGAN ALAT SAMBUNG BAUT, IJUK, DAN FIBRE-REINFORCED PLASTIC
title_full KEKUATAN SAMBUNGAN BAMBU DENGAN ALAT SAMBUNG BAUT, IJUK, DAN FIBRE-REINFORCED PLASTIC
title_fullStr KEKUATAN SAMBUNGAN BAMBU DENGAN ALAT SAMBUNG BAUT, IJUK, DAN FIBRE-REINFORCED PLASTIC
title_full_unstemmed KEKUATAN SAMBUNGAN BAMBU DENGAN ALAT SAMBUNG BAUT, IJUK, DAN FIBRE-REINFORCED PLASTIC
title_short KEKUATAN SAMBUNGAN BAMBU DENGAN ALAT SAMBUNG BAUT, IJUK, DAN FIBRE-REINFORCED PLASTIC
title_sort kekuatan sambungan bambu dengan alat sambung baut ijuk dan fibre reinforced plastic
topic ETD
work_keys_str_mv AT vikiandriani kekuatansambunganbambudenganalatsambungbautijukdanfibrereinforcedplastic
AT aliawaludinstmengphd kekuatansambunganbambudenganalatsambungbautijukdanfibrereinforcedplastic