Summary: | On the construction of Cempaka Apartment Grand Dhika City Bekasi project,
bottom structure using concrete slab foundations. With the aim of applying the material
that never learned to calculate the original data used in the planning of the foundation
piles. As well as to deepen the knowledge about the bearing capacity of piles.
In preparing the final report, the method used is the method of observation,
interview methods, Studies Library and Documentation. The manual calculation using
the theories foundation techniques to calculate the axial bearing capacity of piles. The
data used is the data obtained from the planner.
Once the calculation is done manually by the formula, the bearing capacity of
piles safe for use as foundation piles with pile capacity Spun Pile �600mm worth
2392.21 kN and for Bored Pile pole �1000mm worth 6605.75 kN. With capacity on
Pile Cap group type P2, P3, P8, P14 and P37 respectively have a value 7616.797 kN,
12468.63 kN, 52582.01 kN, 52991,567 kN, 159846.66 kN.
|