PERENCANAAN PERBAIKAN GEDUNG C DAN PERKUATAN STRUKTUR TANGGA METRO GEDUNG B PASAR BERINGHARJO YOGYAKARTA

After Yogyakrata earthquake 2006, Beringharjo store C section have high structural damage include column, beam, slab, and vibrating out of metro staircase structure standard. Although Beringharjo store having many retrofitting but still have structural damages that must be handle Identification Beri...

Full description

Bibliographic Details
Main Authors: , WAHYU ADI PRABOWO, , Ir. Hotma Prawoto Sulistyadi, MT.
Format: Thesis
Published: [Yogyakarta] : Universitas Gadjah Mada 2014
Subjects:
ETD
Description
Summary:After Yogyakrata earthquake 2006, Beringharjo store C section have high structural damage include column, beam, slab, and vibrating out of metro staircase structure standard. Although Beringharjo store having many retrofitting but still have structural damages that must be handle Identification Beringharjo store C section damage must done for damage classification depend on causes so it can be recommended to quality, time, and cost retrofitting As the observation, damage resulting shear crack, minor crack, flexural crack, and spalling. From damage resulting Beringharjo store, shear crack column have high priority. It causes captive column effect, there is a column captive by non structural wall, and there is not. It recommended to column shear reinforce improvement that not captive by wall and wall improvement so that is not happened again. As metro staircase structure strengthen by IWF steel profile then design U form and hanging to staircase beam. It was recommended because staircase beam is main structure close to staircase, then the load transformed to staircase beam