PENGEMBANGAN DAN VALIDASI METODE KROMATOGRAFI CAIR KINERJA TINGGI UNTUK PENETAPAN KADAR CIPROFLOXACIN DALAM SPIKED PLASMA MANUSIA DAN APLIKASINYA UNTUK UJI BIOEKIVALENSI

Ciprofloxacin is a fluoroquinolone type antibiotic agent that is being widely used for the treatment of several bacterial infections. It exhibits broad spectrum antimicrobial activity against Gram negative and Gram positive bacteria. This study aims to develop and validate an HPLC method couple with...

Full description

Bibliographic Details
Main Authors: , Anggun Aji Mukti, , Dr. rer.nat. RR. Endang Lukitaningsih, M.Si., Apt.
Format: Thesis
Published: [Yogyakarta] : Universitas Gadjah Mada 2014
Subjects:
ETD
_version_ 1797036032406847488
author , Anggun Aji Mukti
, Dr. rer.nat. RR. Endang Lukitaningsih, M.Si., Apt.
author_facet , Anggun Aji Mukti
, Dr. rer.nat. RR. Endang Lukitaningsih, M.Si., Apt.
author_sort , Anggun Aji Mukti
collection UGM
description Ciprofloxacin is a fluoroquinolone type antibiotic agent that is being widely used for the treatment of several bacterial infections. It exhibits broad spectrum antimicrobial activity against Gram negative and Gram positive bacteria. This study aims to develop and validate an HPLC method couple with a UV detection for determination of ciprofloxacin in spiked human plasma and its application for bioequivalence study. HPLC method using an RP-C18 column (Lachrom Hitachi, 250 x 4,6 mm., 5μm), mobile phase of phosphate buffer (pH 3 ± 0,1 ) : acetonitrile (87 : 13) , a flow rate of 1,5 mL / min with ultraviolet detection at 276,6 nm. The limid of detection is 0,07 μg/mL. The regression equation are linear (r > 0,999) This method was successfully applied to bioequivalence study of two product of 500 mg ciprofloxacin. For bioequivalence study was obtained (90% CI) ratio of Cmax = 74,08-124,60%, (90% CI) AUCt(0-12) ratio = 83,53-122,14 % and (90% CI) ratio AUCt(0- ) = 86,07- 120,92%.
first_indexed 2024-03-13T23:39:44Z
format Thesis
id oai:generic.eprints.org:133584
institution Universiti Gadjah Mada
last_indexed 2024-03-13T23:39:44Z
publishDate 2014
publisher [Yogyakarta] : Universitas Gadjah Mada
record_format dspace
spelling oai:generic.eprints.org:1335842016-03-04T07:53:04Z https://repository.ugm.ac.id/133584/ PENGEMBANGAN DAN VALIDASI METODE KROMATOGRAFI CAIR KINERJA TINGGI UNTUK PENETAPAN KADAR CIPROFLOXACIN DALAM SPIKED PLASMA MANUSIA DAN APLIKASINYA UNTUK UJI BIOEKIVALENSI , Anggun Aji Mukti , Dr. rer.nat. RR. Endang Lukitaningsih, M.Si., Apt. ETD Ciprofloxacin is a fluoroquinolone type antibiotic agent that is being widely used for the treatment of several bacterial infections. It exhibits broad spectrum antimicrobial activity against Gram negative and Gram positive bacteria. This study aims to develop and validate an HPLC method couple with a UV detection for determination of ciprofloxacin in spiked human plasma and its application for bioequivalence study. HPLC method using an RP-C18 column (Lachrom Hitachi, 250 x 4,6 mm., 5μm), mobile phase of phosphate buffer (pH 3 ± 0,1 ) : acetonitrile (87 : 13) , a flow rate of 1,5 mL / min with ultraviolet detection at 276,6 nm. The limid of detection is 0,07 μg/mL. The regression equation are linear (r > 0,999) This method was successfully applied to bioequivalence study of two product of 500 mg ciprofloxacin. For bioequivalence study was obtained (90% CI) ratio of Cmax = 74,08-124,60%, (90% CI) AUCt(0-12) ratio = 83,53-122,14 % and (90% CI) ratio AUCt(0- ) = 86,07- 120,92%. [Yogyakarta] : Universitas Gadjah Mada 2014 Thesis NonPeerReviewed , Anggun Aji Mukti and , Dr. rer.nat. RR. Endang Lukitaningsih, M.Si., Apt. (2014) PENGEMBANGAN DAN VALIDASI METODE KROMATOGRAFI CAIR KINERJA TINGGI UNTUK PENETAPAN KADAR CIPROFLOXACIN DALAM SPIKED PLASMA MANUSIA DAN APLIKASINYA UNTUK UJI BIOEKIVALENSI. UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=74287
spellingShingle ETD
, Anggun Aji Mukti
, Dr. rer.nat. RR. Endang Lukitaningsih, M.Si., Apt.
PENGEMBANGAN DAN VALIDASI METODE KROMATOGRAFI CAIR KINERJA TINGGI UNTUK PENETAPAN KADAR CIPROFLOXACIN DALAM SPIKED PLASMA MANUSIA DAN APLIKASINYA UNTUK UJI BIOEKIVALENSI
title PENGEMBANGAN DAN VALIDASI METODE KROMATOGRAFI CAIR KINERJA TINGGI UNTUK PENETAPAN KADAR CIPROFLOXACIN DALAM SPIKED PLASMA MANUSIA DAN APLIKASINYA UNTUK UJI BIOEKIVALENSI
title_full PENGEMBANGAN DAN VALIDASI METODE KROMATOGRAFI CAIR KINERJA TINGGI UNTUK PENETAPAN KADAR CIPROFLOXACIN DALAM SPIKED PLASMA MANUSIA DAN APLIKASINYA UNTUK UJI BIOEKIVALENSI
title_fullStr PENGEMBANGAN DAN VALIDASI METODE KROMATOGRAFI CAIR KINERJA TINGGI UNTUK PENETAPAN KADAR CIPROFLOXACIN DALAM SPIKED PLASMA MANUSIA DAN APLIKASINYA UNTUK UJI BIOEKIVALENSI
title_full_unstemmed PENGEMBANGAN DAN VALIDASI METODE KROMATOGRAFI CAIR KINERJA TINGGI UNTUK PENETAPAN KADAR CIPROFLOXACIN DALAM SPIKED PLASMA MANUSIA DAN APLIKASINYA UNTUK UJI BIOEKIVALENSI
title_short PENGEMBANGAN DAN VALIDASI METODE KROMATOGRAFI CAIR KINERJA TINGGI UNTUK PENETAPAN KADAR CIPROFLOXACIN DALAM SPIKED PLASMA MANUSIA DAN APLIKASINYA UNTUK UJI BIOEKIVALENSI
title_sort pengembangan dan validasi metode kromatografi cair kinerja tinggi untuk penetapan kadar ciprofloxacin dalam spiked plasma manusia dan aplikasinya untuk uji bioekivalensi
topic ETD
work_keys_str_mv AT anggunajimukti pengembangandanvalidasimetodekromatograficairkinerjatinggiuntukpenetapankadarciprofloxacindalamspikedplasmamanusiadanaplikasinyauntukujibioekivalensi
AT drrernatrrendanglukitaningsihmsiapt pengembangandanvalidasimetodekromatograficairkinerjatinggiuntukpenetapankadarciprofloxacindalamspikedplasmamanusiadanaplikasinyauntukujibioekivalensi