PERBANDINGAN PENYANGATAN LIEN PADA CT ABDOMEN DENGAN PEMBERIAN BAHAN KONTRAS NON IONIK 300 mgI/ml DOSIS TETAP 80 ml DAN DOSIS 1 ml/kgBB

Background. Most abdominal CT is done by using intravenous non-ionic iodine contrast media. Contrast media usage can cause mild, moderate or severe side effects. Contrast induced nephropathy (CIN) is a common cause of death after injection of contrast media. The risk of CIN can be minimized by re...

Full description

Bibliographic Details
Main Author: Cahyawati, TRIANA DYAH
Format: Thesis
Published: [Yogyakarta] : Universitas Gadjah Mada 2015
Subjects:
_version_ 1826049278682857472
author Cahyawati, TRIANA DYAH
author_facet Cahyawati, TRIANA DYAH
author_sort Cahyawati, TRIANA DYAH
collection UGM
description Background. Most abdominal CT is done by using intravenous non-ionic iodine contrast media. Contrast media usage can cause mild, moderate or severe side effects. Contrast induced nephropathy (CIN) is a common cause of death after injection of contrast media. The risk of CIN can be minimized by reducing the volume of contrast media administration. Abdominal CT procedure in Dr. Sardjito Central General Hospital applies 80 ml of 300 mgI/ml nonionic iodine contrast media, for various patient's weight. To reduce the volume of contrast media, the dose should be adjusted based on body weight, without reducing the image quality. Spleen is one of the abominal organs which enhances with contrast media administration. The aim of this study is to determine the differences of splenic enhancement after administration of fixed dose (80 ml) and an adjusted dose (1 ml/kgbodyweight) nonionic contrast media 300 mgI/ml. Subject and Method. This study was an analytic observational with crosssectional study design. The study was conducted in Radiology Department of Dr. Sardjito Central General Hospital. There were 66 subjects divided into two groups: 33 subjects received fixed doses of contrast media (80 ml) and 33 subjects received adjusted dose based on body weight (1 ml/kg). Splenic density measured on abdominal CT, before and after contrast media administration. The difference of splenic enhancement over baseline in each group was statistically analized using Independent T test or Mann-Whitney test. Statistically significance was accepted at p < 0.05. Result. The mean increase in splenic enhancement on the portal venous phase compared to the baseline in the group that received iopamidol 300 mgI/ml with a fixed dose 80 ml was 64,17 HU (SD ±15,81), and in the group received iopamidol 300 mgI/ml based on body weight (1 ml/kg) was 46,06 HU (SD ±15,81), with p value <0,05. Conclusion. This study found that splenic enhancement on the portal venous phase in the subjects who received iopamidol 300 mgI/ml with a fixed dose 80 ml was higher than the subjects who received iopamidol 300 mgI/ml based on body weight (1 ml/kg), which was statistically significant (p<0,05).
first_indexed 2024-03-13T23:43:24Z
format Thesis
id oai:generic.eprints.org:134728
institution Universiti Gadjah Mada
last_indexed 2024-03-13T23:43:24Z
publishDate 2015
publisher [Yogyakarta] : Universitas Gadjah Mada
record_format dspace
spelling oai:generic.eprints.org:1347282016-04-15T04:08:18Z https://repository.ugm.ac.id/134728/ PERBANDINGAN PENYANGATAN LIEN PADA CT ABDOMEN DENGAN PEMBERIAN BAHAN KONTRAS NON IONIK 300 mgI/ml DOSIS TETAP 80 ml DAN DOSIS 1 ml/kgBB Cahyawati, TRIANA DYAH Clinical Sciences Radiology and Organ Imaging Background. Most abdominal CT is done by using intravenous non-ionic iodine contrast media. Contrast media usage can cause mild, moderate or severe side effects. Contrast induced nephropathy (CIN) is a common cause of death after injection of contrast media. The risk of CIN can be minimized by reducing the volume of contrast media administration. Abdominal CT procedure in Dr. Sardjito Central General Hospital applies 80 ml of 300 mgI/ml nonionic iodine contrast media, for various patient's weight. To reduce the volume of contrast media, the dose should be adjusted based on body weight, without reducing the image quality. Spleen is one of the abominal organs which enhances with contrast media administration. The aim of this study is to determine the differences of splenic enhancement after administration of fixed dose (80 ml) and an adjusted dose (1 ml/kgbodyweight) nonionic contrast media 300 mgI/ml. Subject and Method. This study was an analytic observational with crosssectional study design. The study was conducted in Radiology Department of Dr. Sardjito Central General Hospital. There were 66 subjects divided into two groups: 33 subjects received fixed doses of contrast media (80 ml) and 33 subjects received adjusted dose based on body weight (1 ml/kg). Splenic density measured on abdominal CT, before and after contrast media administration. The difference of splenic enhancement over baseline in each group was statistically analized using Independent T test or Mann-Whitney test. Statistically significance was accepted at p < 0.05. Result. The mean increase in splenic enhancement on the portal venous phase compared to the baseline in the group that received iopamidol 300 mgI/ml with a fixed dose 80 ml was 64,17 HU (SD ±15,81), and in the group received iopamidol 300 mgI/ml based on body weight (1 ml/kg) was 46,06 HU (SD ±15,81), with p value <0,05. Conclusion. This study found that splenic enhancement on the portal venous phase in the subjects who received iopamidol 300 mgI/ml with a fixed dose 80 ml was higher than the subjects who received iopamidol 300 mgI/ml based on body weight (1 ml/kg), which was statistically significant (p<0,05). [Yogyakarta] : Universitas Gadjah Mada 2015 Thesis NonPeerReviewed Cahyawati, TRIANA DYAH (2015) PERBANDINGAN PENYANGATAN LIEN PADA CT ABDOMEN DENGAN PEMBERIAN BAHAN KONTRAS NON IONIK 300 mgI/ml DOSIS TETAP 80 ml DAN DOSIS 1 ml/kgBB. Masters thesis, UGM. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=77794
spellingShingle Clinical Sciences
Radiology and Organ Imaging
Cahyawati, TRIANA DYAH
PERBANDINGAN PENYANGATAN LIEN PADA CT ABDOMEN DENGAN PEMBERIAN BAHAN KONTRAS NON IONIK 300 mgI/ml DOSIS TETAP 80 ml DAN DOSIS 1 ml/kgBB
title PERBANDINGAN PENYANGATAN LIEN PADA CT ABDOMEN DENGAN PEMBERIAN BAHAN KONTRAS NON IONIK 300 mgI/ml DOSIS TETAP 80 ml DAN DOSIS 1 ml/kgBB
title_full PERBANDINGAN PENYANGATAN LIEN PADA CT ABDOMEN DENGAN PEMBERIAN BAHAN KONTRAS NON IONIK 300 mgI/ml DOSIS TETAP 80 ml DAN DOSIS 1 ml/kgBB
title_fullStr PERBANDINGAN PENYANGATAN LIEN PADA CT ABDOMEN DENGAN PEMBERIAN BAHAN KONTRAS NON IONIK 300 mgI/ml DOSIS TETAP 80 ml DAN DOSIS 1 ml/kgBB
title_full_unstemmed PERBANDINGAN PENYANGATAN LIEN PADA CT ABDOMEN DENGAN PEMBERIAN BAHAN KONTRAS NON IONIK 300 mgI/ml DOSIS TETAP 80 ml DAN DOSIS 1 ml/kgBB
title_short PERBANDINGAN PENYANGATAN LIEN PADA CT ABDOMEN DENGAN PEMBERIAN BAHAN KONTRAS NON IONIK 300 mgI/ml DOSIS TETAP 80 ml DAN DOSIS 1 ml/kgBB
title_sort perbandingan penyangatan lien pada ct abdomen dengan pemberian bahan kontras non ionik 300 mgi ml dosis tetap 80 ml dan dosis 1 ml kgbb
topic Clinical Sciences
Radiology and Organ Imaging
work_keys_str_mv AT cahyawatitrianadyah perbandinganpenyangatanlienpadactabdomendenganpemberianbahankontrasnonionik300mgimldosistetap80mldandosis1mlkgbb