The Effect Of Fast Front Impulse Waveshape Upon The Electrical Transformator Distribution Voltage

The invention of vacuum circuit breaker enables to switch on an electrical circuit in a very fast time due to short gap between the circuit breaker contacts. This means that the voltage applied to the electrical circuit has a very steep front time or contains high frequency components Electrical tra...

Full description

Bibliographic Details
Main Author: Perpustakaan UGM, i-lib
Format: Article
Published: [Yogyakarta] : Universitas Gadjah Mada 1998
Subjects:
_version_ 1797017788320055296
author Perpustakaan UGM, i-lib
author_facet Perpustakaan UGM, i-lib
author_sort Perpustakaan UGM, i-lib
collection UGM
description The invention of vacuum circuit breaker enables to switch on an electrical circuit in a very fast time due to short gap between the circuit breaker contacts. This means that the voltage applied to the electrical circuit has a very steep front time or contains high frequency components Electrical transformator winding is simulated by an inductor having nine taps representing distributed sections of an electrical transformator winding. The very fast front time of voltage produced by a low voltage recurrent surge generator is applied to the inductor. The results of this investigation reveal that the steeper the front time of an impulse waveshape of voltage applied to the transformator causes the more voltage stress to the part of winding closest to the line terminal.
first_indexed 2024-03-13T18:35:33Z
format Article
id oai:generic.eprints.org:18289
institution Universiti Gadjah Mada
last_indexed 2024-03-13T18:35:33Z
publishDate 1998
publisher [Yogyakarta] : Universitas Gadjah Mada
record_format dspace
spelling oai:generic.eprints.org:182892014-06-18T00:36:49Z https://repository.ugm.ac.id/18289/ The Effect Of Fast Front Impulse Waveshape Upon The Electrical Transformator Distribution Voltage Perpustakaan UGM, i-lib Jurnal i-lib UGM The invention of vacuum circuit breaker enables to switch on an electrical circuit in a very fast time due to short gap between the circuit breaker contacts. This means that the voltage applied to the electrical circuit has a very steep front time or contains high frequency components Electrical transformator winding is simulated by an inductor having nine taps representing distributed sections of an electrical transformator winding. The very fast front time of voltage produced by a low voltage recurrent surge generator is applied to the inductor. The results of this investigation reveal that the steeper the front time of an impulse waveshape of voltage applied to the transformator causes the more voltage stress to the part of winding closest to the line terminal. [Yogyakarta] : Universitas Gadjah Mada 1998 Article NonPeerReviewed Perpustakaan UGM, i-lib (1998) The Effect Of Fast Front Impulse Waveshape Upon The Electrical Transformator Distribution Voltage. Jurnal i-lib UGM. http://i-lib.ugm.ac.id/jurnal/download.php?dataId=1070
spellingShingle Jurnal i-lib UGM
Perpustakaan UGM, i-lib
The Effect Of Fast Front Impulse Waveshape Upon The Electrical Transformator Distribution Voltage
title The Effect Of Fast Front Impulse Waveshape Upon The Electrical Transformator Distribution Voltage
title_full The Effect Of Fast Front Impulse Waveshape Upon The Electrical Transformator Distribution Voltage
title_fullStr The Effect Of Fast Front Impulse Waveshape Upon The Electrical Transformator Distribution Voltage
title_full_unstemmed The Effect Of Fast Front Impulse Waveshape Upon The Electrical Transformator Distribution Voltage
title_short The Effect Of Fast Front Impulse Waveshape Upon The Electrical Transformator Distribution Voltage
title_sort effect of fast front impulse waveshape upon the electrical transformator distribution voltage
topic Jurnal i-lib UGM
work_keys_str_mv AT perpustakaanugmilib theeffectoffastfrontimpulsewaveshapeupontheelectricaltransformatordistributionvoltage
AT perpustakaanugmilib effectoffastfrontimpulsewaveshapeupontheelectricaltransformatordistributionvoltage