Pendeteksian kegagalan actuator pada sistem tangki berpengaduk

ABSTRACT Non zero set points stirred tank control systems can be found in industries. The set points are related to maintain the quality of products. An actuator failure should be detected immediately or it will jeopardize the entire control strategy. A problem with a traditional controller (designe...

Full description

Bibliographic Details
Main Author: Perpustakaan UGM, i-lib
Format: Article
Published: [Yogyakarta] : Universitas Gadjah Mada 1997
Subjects:
_version_ 1797017844789018624
author Perpustakaan UGM, i-lib
author_facet Perpustakaan UGM, i-lib
author_sort Perpustakaan UGM, i-lib
collection UGM
description ABSTRACT Non zero set points stirred tank control systems can be found in industries. The set points are related to maintain the quality of products. An actuator failure should be detected immediately or it will jeopardize the entire control strategy. A problem with a traditional controller (designed mainly to solve a control problem) is that its sructure does not give a facility for reducing the interaction between an actuator and outputs of the plant. Therefore, an actuator failure detection through outputs of the plant becomes difficult as it will be demonstrated in this paper. A decoupler based controller is designed to solve the problem mentioned above. Moreover, sensors contaminated by white noise are considered. The effect of noise can be reduced by using moving windows.
first_indexed 2024-03-05T22:53:51Z
format Article
id oai:generic.eprints.org:18568
institution Universiti Gadjah Mada
last_indexed 2024-03-05T22:53:51Z
publishDate 1997
publisher [Yogyakarta] : Universitas Gadjah Mada
record_format dspace
spelling oai:generic.eprints.org:185682014-06-18T00:38:04Z https://repository.ugm.ac.id/18568/ Pendeteksian kegagalan actuator pada sistem tangki berpengaduk Perpustakaan UGM, i-lib Jurnal i-lib UGM ABSTRACT Non zero set points stirred tank control systems can be found in industries. The set points are related to maintain the quality of products. An actuator failure should be detected immediately or it will jeopardize the entire control strategy. A problem with a traditional controller (designed mainly to solve a control problem) is that its sructure does not give a facility for reducing the interaction between an actuator and outputs of the plant. Therefore, an actuator failure detection through outputs of the plant becomes difficult as it will be demonstrated in this paper. A decoupler based controller is designed to solve the problem mentioned above. Moreover, sensors contaminated by white noise are considered. The effect of noise can be reduced by using moving windows. [Yogyakarta] : Universitas Gadjah Mada 1997 Article NonPeerReviewed Perpustakaan UGM, i-lib (1997) Pendeteksian kegagalan actuator pada sistem tangki berpengaduk. Jurnal i-lib UGM. http://i-lib.ugm.ac.id/jurnal/download.php?dataId=1360
spellingShingle Jurnal i-lib UGM
Perpustakaan UGM, i-lib
Pendeteksian kegagalan actuator pada sistem tangki berpengaduk
title Pendeteksian kegagalan actuator pada sistem tangki berpengaduk
title_full Pendeteksian kegagalan actuator pada sistem tangki berpengaduk
title_fullStr Pendeteksian kegagalan actuator pada sistem tangki berpengaduk
title_full_unstemmed Pendeteksian kegagalan actuator pada sistem tangki berpengaduk
title_short Pendeteksian kegagalan actuator pada sistem tangki berpengaduk
title_sort pendeteksian kegagalan actuator pada sistem tangki berpengaduk
topic Jurnal i-lib UGM
work_keys_str_mv AT perpustakaanugmilib pendeteksiankegagalanactuatorpadasistemtangkiberpengaduk