Model Pengendalian Gerusan LokalAkibat Aliran Superkritik Di Hilir Pintu Air = Model of Local Scouring Control due to Supercritical Flow downstream of a Vertical Gate

ABSTRACT Supercritical water jet resulted from a vertical gate (underflow) has high erosion power which causes a problem on scouring downstream of the gate especially on erodible bed. Therefore river bed protection from local scouring is needed. A method for control this local scouring is using apro...

Full description

Bibliographic Details
Main Author: Perpustakaan UGM, i-lib
Format: Article
Published: [Yogyakarta] : Universitas Gadjah Mada 2002
Subjects:
_version_ 1797018950288015360
author Perpustakaan UGM, i-lib
author_facet Perpustakaan UGM, i-lib
author_sort Perpustakaan UGM, i-lib
collection UGM
description ABSTRACT Supercritical water jet resulted from a vertical gate (underflow) has high erosion power which causes a problem on scouring downstream of the gate especially on erodible bed. Therefore river bed protection from local scouring is needed. A method for control this local scouring is using apron and energy dissipators downstream of the gate. This research was conducted in four models which include apron without energy dissipators, apron with end sill only, apron with baffle blocks only, apron with combination of end sill and baffle blocks. The four models were tested experimentally with variation of flow discharge and tailwater level. Scour parameters covering maximum scour depth, distance of maximum scour and length of the scour hole were observed. The relation between flow parameters and these scour parameters were evaluated. The result showed that 97% of scour depth occured in the first 150180 minutes. Maximum scour depth, distance of maximum scour and length of the scour hole increased with the difference in height between upstream and downstream water levels. Empirical relations for maximum scour were evaluated for each models. End sill gave smallest scour depth reduction (18.71%) but it made maximum scour depth location away from apron. Baffle blocks gave a significant scour depth reduction (37.4%). Application both end sill and baffle blocks result the highest reduction up to 62.63%. Keywods : local scouring, vertical gate, energy dissipators
first_indexed 2024-03-05T23:04:48Z
format Article
id oai:generic.eprints.org:23912
institution Universiti Gadjah Mada
last_indexed 2024-03-13T18:52:10Z
publishDate 2002
publisher [Yogyakarta] : Universitas Gadjah Mada
record_format dspace
spelling oai:generic.eprints.org:239122014-06-18T00:31:45Z https://repository.ugm.ac.id/23912/ Model Pengendalian Gerusan LokalAkibat Aliran Superkritik Di Hilir Pintu Air = Model of Local Scouring Control due to Supercritical Flow downstream of a Vertical Gate Perpustakaan UGM, i-lib Jurnal i-lib UGM ABSTRACT Supercritical water jet resulted from a vertical gate (underflow) has high erosion power which causes a problem on scouring downstream of the gate especially on erodible bed. Therefore river bed protection from local scouring is needed. A method for control this local scouring is using apron and energy dissipators downstream of the gate. This research was conducted in four models which include apron without energy dissipators, apron with end sill only, apron with baffle blocks only, apron with combination of end sill and baffle blocks. The four models were tested experimentally with variation of flow discharge and tailwater level. Scour parameters covering maximum scour depth, distance of maximum scour and length of the scour hole were observed. The relation between flow parameters and these scour parameters were evaluated. The result showed that 97% of scour depth occured in the first 150180 minutes. Maximum scour depth, distance of maximum scour and length of the scour hole increased with the difference in height between upstream and downstream water levels. Empirical relations for maximum scour were evaluated for each models. End sill gave smallest scour depth reduction (18.71%) but it made maximum scour depth location away from apron. Baffle blocks gave a significant scour depth reduction (37.4%). Application both end sill and baffle blocks result the highest reduction up to 62.63%. Keywods : local scouring, vertical gate, energy dissipators [Yogyakarta] : Universitas Gadjah Mada 2002 Article NonPeerReviewed Perpustakaan UGM, i-lib (2002) Model Pengendalian Gerusan LokalAkibat Aliran Superkritik Di Hilir Pintu Air = Model of Local Scouring Control due to Supercritical Flow downstream of a Vertical Gate. Jurnal i-lib UGM. http://i-lib.ugm.ac.id/jurnal/download.php?dataId=6876
spellingShingle Jurnal i-lib UGM
Perpustakaan UGM, i-lib
Model Pengendalian Gerusan LokalAkibat Aliran Superkritik Di Hilir Pintu Air = Model of Local Scouring Control due to Supercritical Flow downstream of a Vertical Gate
title Model Pengendalian Gerusan LokalAkibat Aliran Superkritik Di Hilir Pintu Air = Model of Local Scouring Control due to Supercritical Flow downstream of a Vertical Gate
title_full Model Pengendalian Gerusan LokalAkibat Aliran Superkritik Di Hilir Pintu Air = Model of Local Scouring Control due to Supercritical Flow downstream of a Vertical Gate
title_fullStr Model Pengendalian Gerusan LokalAkibat Aliran Superkritik Di Hilir Pintu Air = Model of Local Scouring Control due to Supercritical Flow downstream of a Vertical Gate
title_full_unstemmed Model Pengendalian Gerusan LokalAkibat Aliran Superkritik Di Hilir Pintu Air = Model of Local Scouring Control due to Supercritical Flow downstream of a Vertical Gate
title_short Model Pengendalian Gerusan LokalAkibat Aliran Superkritik Di Hilir Pintu Air = Model of Local Scouring Control due to Supercritical Flow downstream of a Vertical Gate
title_sort model pengendalian gerusan lokalakibat aliran superkritik di hilir pintu air model of local scouring control due to supercritical flow downstream of a vertical gate
topic Jurnal i-lib UGM
work_keys_str_mv AT perpustakaanugmilib modelpengendaliangerusanlokalakibataliransuperkritikdihilirpintuairmodeloflocalscouringcontrolduetosupercriticalflowdownstreamofaverticalgate