OPTIMISASI DAN PENGENDALIAN DI DAERAH PENDINGINAN LAMINAR PABRIK BAJA LEMBARAN PANAS (Optimisation and Controlling in The Laminar Cooling Area in The Hot Strip Mill)

ABSTRACT In the rolling process of steel slab in the FISM (Hot Strip Mill) there are several criteria to be satisfied, among other thing the rolling .temperature between 550--650°C. This requires controlling operation in laminar cooling area. The determination temperature distribution of steel slab...

Full description

Bibliographic Details
Main Author: Perpustakaan UGM, i-lib
Format: Article
Published: [Yogyakarta] : SekolahPascasarjana Universitas GadjahMada 2000
Subjects:
_version_ 1797019048982085632
author Perpustakaan UGM, i-lib
author_facet Perpustakaan UGM, i-lib
author_sort Perpustakaan UGM, i-lib
collection UGM
description ABSTRACT In the rolling process of steel slab in the FISM (Hot Strip Mill) there are several criteria to be satisfied, among other thing the rolling .temperature between 550--650°C. This requires controlling operation in laminar cooling area. The determination temperature distribution of steel slab in cooling area was done using a numerical method, to determine the best combination of process variables (rate of movement of steel slab and flow rate of water cooling) to arrive at some optimal condition. For steel slab's dimension of 60 m x 1.2 m x 0.02 m, 0.19 -0.20 m/s for rate of movement of steel slab, and 230 � 260 m3/h for flow rate of water cooling were the optimal set up. Water cooling applied to both surfaces was better than water cooling only to one surface. Controlling two process variables used to fuzzy logic controller (FLC) until the temperature of steel slab was ± 600° C. Keywords : optimisation, controlling, laminar cooling, hot strip mill
first_indexed 2024-03-05T23:05:27Z
format Article
id oai:generic.eprints.org:24404
institution Universiti Gadjah Mada
last_indexed 2024-03-13T18:53:42Z
publishDate 2000
publisher [Yogyakarta] : SekolahPascasarjana Universitas GadjahMada
record_format dspace
spelling oai:generic.eprints.org:244042014-06-18T00:34:07Z https://repository.ugm.ac.id/24404/ OPTIMISASI DAN PENGENDALIAN DI DAERAH PENDINGINAN LAMINAR PABRIK BAJA LEMBARAN PANAS (Optimisation and Controlling in The Laminar Cooling Area in The Hot Strip Mill) Perpustakaan UGM, i-lib Jurnal i-lib UGM ABSTRACT In the rolling process of steel slab in the FISM (Hot Strip Mill) there are several criteria to be satisfied, among other thing the rolling .temperature between 550--650°C. This requires controlling operation in laminar cooling area. The determination temperature distribution of steel slab in cooling area was done using a numerical method, to determine the best combination of process variables (rate of movement of steel slab and flow rate of water cooling) to arrive at some optimal condition. For steel slab's dimension of 60 m x 1.2 m x 0.02 m, 0.19 -0.20 m/s for rate of movement of steel slab, and 230 � 260 m3/h for flow rate of water cooling were the optimal set up. Water cooling applied to both surfaces was better than water cooling only to one surface. Controlling two process variables used to fuzzy logic controller (FLC) until the temperature of steel slab was ± 600° C. Keywords : optimisation, controlling, laminar cooling, hot strip mill [Yogyakarta] : SekolahPascasarjana Universitas GadjahMada 2000 Article NonPeerReviewed Perpustakaan UGM, i-lib (2000) OPTIMISASI DAN PENGENDALIAN DI DAERAH PENDINGINAN LAMINAR PABRIK BAJA LEMBARAN PANAS (Optimisation and Controlling in The Laminar Cooling Area in The Hot Strip Mill). Jurnal i-lib UGM. http://i-lib.ugm.ac.id/jurnal/download.php?dataId=7377
spellingShingle Jurnal i-lib UGM
Perpustakaan UGM, i-lib
OPTIMISASI DAN PENGENDALIAN DI DAERAH PENDINGINAN LAMINAR PABRIK BAJA LEMBARAN PANAS (Optimisation and Controlling in The Laminar Cooling Area in The Hot Strip Mill)
title OPTIMISASI DAN PENGENDALIAN DI DAERAH PENDINGINAN LAMINAR PABRIK BAJA LEMBARAN PANAS (Optimisation and Controlling in The Laminar Cooling Area in The Hot Strip Mill)
title_full OPTIMISASI DAN PENGENDALIAN DI DAERAH PENDINGINAN LAMINAR PABRIK BAJA LEMBARAN PANAS (Optimisation and Controlling in The Laminar Cooling Area in The Hot Strip Mill)
title_fullStr OPTIMISASI DAN PENGENDALIAN DI DAERAH PENDINGINAN LAMINAR PABRIK BAJA LEMBARAN PANAS (Optimisation and Controlling in The Laminar Cooling Area in The Hot Strip Mill)
title_full_unstemmed OPTIMISASI DAN PENGENDALIAN DI DAERAH PENDINGINAN LAMINAR PABRIK BAJA LEMBARAN PANAS (Optimisation and Controlling in The Laminar Cooling Area in The Hot Strip Mill)
title_short OPTIMISASI DAN PENGENDALIAN DI DAERAH PENDINGINAN LAMINAR PABRIK BAJA LEMBARAN PANAS (Optimisation and Controlling in The Laminar Cooling Area in The Hot Strip Mill)
title_sort optimisasi dan pengendalian di daerah pendinginan laminar pabrik baja lembaran panas optimisation and controlling in the laminar cooling area in the hot strip mill
topic Jurnal i-lib UGM
work_keys_str_mv AT perpustakaanugmilib optimisasidanpengendaliandidaerahpendinginanlaminarpabrikbajalembaranpanasoptimisationandcontrollinginthelaminarcoolingareainthehotstripmill