Analisis Operasi Paralel Generator Induksi Penguatan Sendiri

Indonesia is an archipelago country which is located in tropical area. It has many renewable energy resources such as water and wind. These resources are scaterred around the country. These renewable energy resources can be conversed into electrical energy using induction generator as an isolated...

Full description

Bibliographic Details
Main Authors: Wijaya, Fransisco Danang, Wijoyo, Yusuf Susilo, Dito, kevin, setyonegoro, mokhamad
Format: Conference or Workshop Item
Language:English
Published: 2013
Subjects:
Online Access:https://repository.ugm.ac.id/273733/1/Analisis%20Operasi%20Paralel%20Generator%20Induksi%20Penguatan%20Sendiri.pdf
_version_ 1797036770693480448
author Wijaya, Fransisco Danang
Wijoyo, Yusuf Susilo
Dito, kevin
setyonegoro, mokhamad
author_facet Wijaya, Fransisco Danang
Wijoyo, Yusuf Susilo
Dito, kevin
setyonegoro, mokhamad
author_sort Wijaya, Fransisco Danang
collection UGM
description Indonesia is an archipelago country which is located in tropical area. It has many renewable energy resources such as water and wind. These resources are scaterred around the country. These renewable energy resources can be conversed into electrical energy using induction generator as an isolated system. Induction generator can be selected because its has simple and robust construction, maintenance free, low cost and available in the local market. Generally, the induction generator is operated as an isolated system using self excitation (SEIG-Self Excited Induction Generator) which is produced by capacitor. In order to increase the capacity, paralel operation of the induction generator is applied. The aims of this research are to determaine the characteristic of SEIG, to analize parallel operation of SEIG and to develope practical paralel operation procedure. The research was done by simulation using software and then verified with experiment. The results showed that SEIG required capacitor as self excitation. In the paralel operation, they did not need special synchronization. The generators must be in negatif slip condition. Load sharing between two generators is determined by the rotary speed of the prime mover. Finally, based on the experiment the practical paralel operation procedure has been developed.
first_indexed 2024-03-13T23:51:29Z
format Conference or Workshop Item
id oai:generic.eprints.org:273733
institution Universiti Gadjah Mada
language English
last_indexed 2024-03-13T23:51:29Z
publishDate 2013
record_format dspace
spelling oai:generic.eprints.org:2737332017-11-06T08:31:19Z https://repository.ugm.ac.id/273733/ Analisis Operasi Paralel Generator Induksi Penguatan Sendiri Wijaya, Fransisco Danang Wijoyo, Yusuf Susilo Dito, kevin setyonegoro, mokhamad Biomedical Engineering Electrical and Electronic Engineering Indonesia is an archipelago country which is located in tropical area. It has many renewable energy resources such as water and wind. These resources are scaterred around the country. These renewable energy resources can be conversed into electrical energy using induction generator as an isolated system. Induction generator can be selected because its has simple and robust construction, maintenance free, low cost and available in the local market. Generally, the induction generator is operated as an isolated system using self excitation (SEIG-Self Excited Induction Generator) which is produced by capacitor. In order to increase the capacity, paralel operation of the induction generator is applied. The aims of this research are to determaine the characteristic of SEIG, to analize parallel operation of SEIG and to develope practical paralel operation procedure. The research was done by simulation using software and then verified with experiment. The results showed that SEIG required capacitor as self excitation. In the paralel operation, they did not need special synchronization. The generators must be in negatif slip condition. Load sharing between two generators is determined by the rotary speed of the prime mover. Finally, based on the experiment the practical paralel operation procedure has been developed. 2013-02-13 Conference or Workshop Item PeerReviewed application/pdf en https://repository.ugm.ac.id/273733/1/Analisis%20Operasi%20Paralel%20Generator%20Induksi%20Penguatan%20Sendiri.pdf Wijaya, Fransisco Danang and Wijoyo, Yusuf Susilo and Dito, kevin and setyonegoro, mokhamad (2013) Analisis Operasi Paralel Generator Induksi Penguatan Sendiri. In: Annual Engineering Seminar 2013, 13 Februari 2013, Yogyakarta, Indonesia. http://seminar-teknik.ft.ugm.ac.id/wp-content/uploads/Leaflet-seminar-teknik-FT-UGM.pdf
spellingShingle Biomedical Engineering
Electrical and Electronic Engineering
Wijaya, Fransisco Danang
Wijoyo, Yusuf Susilo
Dito, kevin
setyonegoro, mokhamad
Analisis Operasi Paralel Generator Induksi Penguatan Sendiri
title Analisis Operasi Paralel Generator Induksi Penguatan Sendiri
title_full Analisis Operasi Paralel Generator Induksi Penguatan Sendiri
title_fullStr Analisis Operasi Paralel Generator Induksi Penguatan Sendiri
title_full_unstemmed Analisis Operasi Paralel Generator Induksi Penguatan Sendiri
title_short Analisis Operasi Paralel Generator Induksi Penguatan Sendiri
title_sort analisis operasi paralel generator induksi penguatan sendiri
topic Biomedical Engineering
Electrical and Electronic Engineering
url https://repository.ugm.ac.id/273733/1/Analisis%20Operasi%20Paralel%20Generator%20Induksi%20Penguatan%20Sendiri.pdf
work_keys_str_mv AT wijayafransiscodanang analisisoperasiparalelgeneratorinduksipenguatansendiri
AT wijoyoyusufsusilo analisisoperasiparalelgeneratorinduksipenguatansendiri
AT ditokevin analisisoperasiparalelgeneratorinduksipenguatansendiri
AT setyonegoromokhamad analisisoperasiparalelgeneratorinduksipenguatansendiri