An Approach to Assess the 500 kV Insulator String Condition Using Ultraviolet Imager

The condition of each cup-and-pin insulator that forms a string must be considered in order to obtain effective guidance for contamination flashover mitigation. This paper describes an approach to assess the string condition based on the ultraviolet (UV) emitted by each cup-and-pin insulator during...

Full description

Bibliographic Details
Main Authors: Dewanto, Faiq Arkan, Khakim, Adityadika Miftakhul, Tumiran, Tumiran, Wahyudi, Mochammad, Setiawan, Noor Akhmad, Saputra, Dharma
Format: Article
Language:English
Published: MDPI 2022
Subjects:
Online Access:https://repository.ugm.ac.id/278655/1/Dewanto_TK.pdf
_version_ 1797037323982995456
author Dewanto, Faiq Arkan
Khakim, Adityadika Miftakhul
Tumiran, Tumiran
Wahyudi, Mochammad
Setiawan, Noor Akhmad
Saputra, Dharma
author_facet Dewanto, Faiq Arkan
Khakim, Adityadika Miftakhul
Tumiran, Tumiran
Wahyudi, Mochammad
Setiawan, Noor Akhmad
Saputra, Dharma
author_sort Dewanto, Faiq Arkan
collection UGM
description The condition of each cup-and-pin insulator that forms a string must be considered in order to obtain effective guidance for contamination flashover mitigation. This paper describes an approach to assess the string condition based on the ultraviolet (UV) emitted by each cup-and-pin insulator during partial discharge condition. The UV patterns on the string were observed visually in the laboratory test. The criteria of string condition level was built based on the patterns and applied to the strings installed in the field. The index value expressing the string condition level in the field (level status) was then compared with the UV quantitative parameter extracted from the UV video. At the final stage, a logarithmic regression classification model was built based on these two values. The laboratory test results showed that there were three levels of string condition, namely level one (safest), level two, and level three (most dangerous). Most strings in the field had category level two, while most strings with level three were of the suspension type. The UV emission area parameters expressed in pixels and percentages were able to represent the sporadic nature of the discharge phenomenon. The proposed approach provided a predictive model with a mean absolute error of 0.182.
first_indexed 2024-03-14T00:01:44Z
format Article
id oai:generic.eprints.org:278655
institution Universiti Gadjah Mada
language English
last_indexed 2024-03-14T00:01:44Z
publishDate 2022
publisher MDPI
record_format dspace
spelling oai:generic.eprints.org:2786552023-11-02T01:17:31Z https://repository.ugm.ac.id/278655/ An Approach to Assess the 500 kV Insulator String Condition Using Ultraviolet Imager Dewanto, Faiq Arkan Khakim, Adityadika Miftakhul Tumiran, Tumiran Wahyudi, Mochammad Setiawan, Noor Akhmad Saputra, Dharma Electrical and Electronic Engineering The condition of each cup-and-pin insulator that forms a string must be considered in order to obtain effective guidance for contamination flashover mitigation. This paper describes an approach to assess the string condition based on the ultraviolet (UV) emitted by each cup-and-pin insulator during partial discharge condition. The UV patterns on the string were observed visually in the laboratory test. The criteria of string condition level was built based on the patterns and applied to the strings installed in the field. The index value expressing the string condition level in the field (level status) was then compared with the UV quantitative parameter extracted from the UV video. At the final stage, a logarithmic regression classification model was built based on these two values. The laboratory test results showed that there were three levels of string condition, namely level one (safest), level two, and level three (most dangerous). Most strings in the field had category level two, while most strings with level three were of the suspension type. The UV emission area parameters expressed in pixels and percentages were able to represent the sporadic nature of the discharge phenomenon. The proposed approach provided a predictive model with a mean absolute error of 0.182. MDPI 2022-11-25 Article PeerReviewed application/pdf en https://repository.ugm.ac.id/278655/1/Dewanto_TK.pdf Dewanto, Faiq Arkan and Khakim, Adityadika Miftakhul and Tumiran, Tumiran and Wahyudi, Mochammad and Setiawan, Noor Akhmad and Saputra, Dharma (2022) An Approach to Assess the 500 kV Insulator String Condition Using Ultraviolet Imager. Appl. Sci., 2022 (12). pp. 1-13. ISSN 2076-3417 https://www.mdpi.com/journal/applsci https://doi.org/10.3390/app122312054
spellingShingle Electrical and Electronic Engineering
Dewanto, Faiq Arkan
Khakim, Adityadika Miftakhul
Tumiran, Tumiran
Wahyudi, Mochammad
Setiawan, Noor Akhmad
Saputra, Dharma
An Approach to Assess the 500 kV Insulator String Condition Using Ultraviolet Imager
title An Approach to Assess the 500 kV Insulator String Condition Using Ultraviolet Imager
title_full An Approach to Assess the 500 kV Insulator String Condition Using Ultraviolet Imager
title_fullStr An Approach to Assess the 500 kV Insulator String Condition Using Ultraviolet Imager
title_full_unstemmed An Approach to Assess the 500 kV Insulator String Condition Using Ultraviolet Imager
title_short An Approach to Assess the 500 kV Insulator String Condition Using Ultraviolet Imager
title_sort approach to assess the 500 kv insulator string condition using ultraviolet imager
topic Electrical and Electronic Engineering
url https://repository.ugm.ac.id/278655/1/Dewanto_TK.pdf
work_keys_str_mv AT dewantofaiqarkan anapproachtoassessthe500kvinsulatorstringconditionusingultravioletimager
AT khakimadityadikamiftakhul anapproachtoassessthe500kvinsulatorstringconditionusingultravioletimager
AT tumirantumiran anapproachtoassessthe500kvinsulatorstringconditionusingultravioletimager
AT wahyudimochammad anapproachtoassessthe500kvinsulatorstringconditionusingultravioletimager
AT setiawannoorakhmad anapproachtoassessthe500kvinsulatorstringconditionusingultravioletimager
AT saputradharma anapproachtoassessthe500kvinsulatorstringconditionusingultravioletimager
AT dewantofaiqarkan approachtoassessthe500kvinsulatorstringconditionusingultravioletimager
AT khakimadityadikamiftakhul approachtoassessthe500kvinsulatorstringconditionusingultravioletimager
AT tumirantumiran approachtoassessthe500kvinsulatorstringconditionusingultravioletimager
AT wahyudimochammad approachtoassessthe500kvinsulatorstringconditionusingultravioletimager
AT setiawannoorakhmad approachtoassessthe500kvinsulatorstringconditionusingultravioletimager
AT saputradharma approachtoassessthe500kvinsulatorstringconditionusingultravioletimager