DETERMINATIONOF CARBAMATEPESTICIDESUSINGA BIOSENSOR BASEDON ENZYMEACETYLCHOLINESTERASEANDCHOLINOXIDASE ON PLATINUMELECTRODE

ABSTRACT In recent years, instead of their potential hazard to human health, carbamic pesticides are widely used in agriculture. Therefore, there is a growing interest in rapid and accurate determination for food safety and environmental monitoring. The aim of this research is to designs a biosenso...

Full description

Bibliographic Details
Main Author: Perpustakaan UGM, i-lib
Format: Article
Published: [Yogyakarta] : Universitas Gadjah Mada 2010
Subjects:
_version_ 1797019833781452800
author Perpustakaan UGM, i-lib
author_facet Perpustakaan UGM, i-lib
author_sort Perpustakaan UGM, i-lib
collection UGM
description ABSTRACT In recent years, instead of their potential hazard to human health, carbamic pesticides are widely used in agriculture. Therefore, there is a growing interest in rapid and accurate determination for food safety and environmental monitoring. The aim of this research is to designs a biosensor for analyzing carbamate pesticides residue in sample with composite variables of glutaraldehyde (GA) concentration in electrode membrane. Enzyme acetylcholinesterase (AChE) was co-immobilised with choline oxidase (ChO) onto a platinum (Pt) surface using a solution of 5%, 10%, 15%cellulose acetate and 25% glutaraldehyde. The result of this research show that detection limit of the sensor using cellulose acetate 5%, 10 % and 15 % are 10-7.7M, 1US.7M and 1(17.6M respectively. The results are approximatelyequal to 2.2 ppb-0.2 ppb, which means that this biosensor is very sensitive for determining carbamates pesticides residue. Detection limit of biosensors are comparable to that of the conventional instrument such as Gas Chromatography (GC) and High Pressure Liquid Chromatography (HPLC), i.e. 1.5 ppb and 2.0 ppb respectively. The proposed electrochemical pesticide sensitivity test exhibited high sensitivity, desirable accuracy, low cost and simplified procedure. Keywords: Biosensors, glutaraldehyde, cellulose acetate, immobilised, carbamate pesticides
first_indexed 2024-03-05T23:12:02Z
format Article
id oai:generic.eprints.org:28095
institution Universiti Gadjah Mada
last_indexed 2024-03-05T23:12:02Z
publishDate 2010
publisher [Yogyakarta] : Universitas Gadjah Mada
record_format dspace
spelling oai:generic.eprints.org:280952014-06-18T00:23:53Z https://repository.ugm.ac.id/28095/ DETERMINATIONOF CARBAMATEPESTICIDESUSINGA BIOSENSOR BASEDON ENZYMEACETYLCHOLINESTERASEANDCHOLINOXIDASE ON PLATINUMELECTRODE Perpustakaan UGM, i-lib Jurnal i-lib UGM ABSTRACT In recent years, instead of their potential hazard to human health, carbamic pesticides are widely used in agriculture. Therefore, there is a growing interest in rapid and accurate determination for food safety and environmental monitoring. The aim of this research is to designs a biosensor for analyzing carbamate pesticides residue in sample with composite variables of glutaraldehyde (GA) concentration in electrode membrane. Enzyme acetylcholinesterase (AChE) was co-immobilised with choline oxidase (ChO) onto a platinum (Pt) surface using a solution of 5%, 10%, 15%cellulose acetate and 25% glutaraldehyde. The result of this research show that detection limit of the sensor using cellulose acetate 5%, 10 % and 15 % are 10-7.7M, 1US.7M and 1(17.6M respectively. The results are approximatelyequal to 2.2 ppb-0.2 ppb, which means that this biosensor is very sensitive for determining carbamates pesticides residue. Detection limit of biosensors are comparable to that of the conventional instrument such as Gas Chromatography (GC) and High Pressure Liquid Chromatography (HPLC), i.e. 1.5 ppb and 2.0 ppb respectively. The proposed electrochemical pesticide sensitivity test exhibited high sensitivity, desirable accuracy, low cost and simplified procedure. Keywords: Biosensors, glutaraldehyde, cellulose acetate, immobilised, carbamate pesticides [Yogyakarta] : Universitas Gadjah Mada 2010 Article NonPeerReviewed Perpustakaan UGM, i-lib (2010) DETERMINATIONOF CARBAMATEPESTICIDESUSINGA BIOSENSOR BASEDON ENZYMEACETYLCHOLINESTERASEANDCHOLINOXIDASE ON PLATINUMELECTRODE. Jurnal i-lib UGM. http://i-lib.ugm.ac.id/jurnal/download.php?dataId=11158
spellingShingle Jurnal i-lib UGM
Perpustakaan UGM, i-lib
DETERMINATIONOF CARBAMATEPESTICIDESUSINGA BIOSENSOR BASEDON ENZYMEACETYLCHOLINESTERASEANDCHOLINOXIDASE ON PLATINUMELECTRODE
title DETERMINATIONOF CARBAMATEPESTICIDESUSINGA BIOSENSOR BASEDON ENZYMEACETYLCHOLINESTERASEANDCHOLINOXIDASE ON PLATINUMELECTRODE
title_full DETERMINATIONOF CARBAMATEPESTICIDESUSINGA BIOSENSOR BASEDON ENZYMEACETYLCHOLINESTERASEANDCHOLINOXIDASE ON PLATINUMELECTRODE
title_fullStr DETERMINATIONOF CARBAMATEPESTICIDESUSINGA BIOSENSOR BASEDON ENZYMEACETYLCHOLINESTERASEANDCHOLINOXIDASE ON PLATINUMELECTRODE
title_full_unstemmed DETERMINATIONOF CARBAMATEPESTICIDESUSINGA BIOSENSOR BASEDON ENZYMEACETYLCHOLINESTERASEANDCHOLINOXIDASE ON PLATINUMELECTRODE
title_short DETERMINATIONOF CARBAMATEPESTICIDESUSINGA BIOSENSOR BASEDON ENZYMEACETYLCHOLINESTERASEANDCHOLINOXIDASE ON PLATINUMELECTRODE
title_sort determinationof carbamatepesticidesusinga biosensor basedon enzymeacetylcholinesteraseandcholinoxidase on platinumelectrode
topic Jurnal i-lib UGM
work_keys_str_mv AT perpustakaanugmilib determinationofcarbamatepesticidesusingabiosensorbasedonenzymeacetylcholinesteraseandcholinoxidaseonplatinumelectrode