Preliminary Design of Floating Photovoltaic at The Logung Dam

A Floating Photovoltaics (FPV) is one type of solar power plant installation with promising performance. This power plant will be designed on the Logung dam with an on-grid system on a 5 MWp scale. This research focused on the analysis of the potential and feasibility of the site, configuration of t...

Full description

Bibliographic Details
Main Authors: Ananda, Rifqi Firza, Budiarto, Rachmawan, Prabowo, Irawan Eko
Format: Conference or Workshop Item
Language:English
Published: 2022
Subjects:
Online Access:https://repository.ugm.ac.id/282148/1/Ananda%20et%20al%20-%202022%20-%20Preliminary_Design_of_Floating_Photovoltaic_at_The_Logung_Dam.pdf
_version_ 1797037543500283904
author Ananda, Rifqi Firza
Budiarto, Rachmawan
Prabowo, Irawan Eko
author_facet Ananda, Rifqi Firza
Budiarto, Rachmawan
Prabowo, Irawan Eko
author_sort Ananda, Rifqi Firza
collection UGM
description A Floating Photovoltaics (FPV) is one type of solar power plant installation with promising performance. This power plant will be designed on the Logung dam with an on-grid system on a 5 MWp scale. This research focused on the analysis of the potential and feasibility of the site, configuration of the FPV components, and system performance. The site analysis was focused on solar radiation, weather, accessibility, and bathymetry. The component configuration is selected based on solar panel and inverter as independent variables. Based on performance specification, the research selected three brands of photovoltaics and two of inverters. The potential analysis showed that the average Global Horizontal Irradiance (GHI) was 5,14 kWh/m2 in the last 10 years. The site is characterized with its good accessibility, sufficient water depth ranging from 70 m to 90 m, and water level fluctuations from 62,46 m to 93,20 m. The selected configuration of floating solar power plant components consist of 12240 panels (450Wp) arranged in 15 series and 816 string solar panels, 51 DC combiner box 100 kW, 100 kW inverter, DC cable between solar panels to the inverter, AC cable between inverter to power grid type NYYHY, floater and mounting system made from HDPE and aluminum, deadweight anchor type, and mooring type loose capstan rope. The design shows a predicted system performance with a capacity factor of 18,61 , system efficiency of 17,51 , and a performance ratio of 83,75. © 2022 IEEE.
first_indexed 2024-03-14T00:04:54Z
format Conference or Workshop Item
id oai:generic.eprints.org:282148
institution Universiti Gadjah Mada
language English
last_indexed 2024-03-14T00:04:54Z
publishDate 2022
record_format dspace
spelling oai:generic.eprints.org:2821482023-11-29T05:56:36Z https://repository.ugm.ac.id/282148/ Preliminary Design of Floating Photovoltaic at The Logung Dam Ananda, Rifqi Firza Budiarto, Rachmawan Prabowo, Irawan Eko Other Engineering Engineering not elsewhere classified A Floating Photovoltaics (FPV) is one type of solar power plant installation with promising performance. This power plant will be designed on the Logung dam with an on-grid system on a 5 MWp scale. This research focused on the analysis of the potential and feasibility of the site, configuration of the FPV components, and system performance. The site analysis was focused on solar radiation, weather, accessibility, and bathymetry. The component configuration is selected based on solar panel and inverter as independent variables. Based on performance specification, the research selected three brands of photovoltaics and two of inverters. The potential analysis showed that the average Global Horizontal Irradiance (GHI) was 5,14 kWh/m2 in the last 10 years. The site is characterized with its good accessibility, sufficient water depth ranging from 70 m to 90 m, and water level fluctuations from 62,46 m to 93,20 m. The selected configuration of floating solar power plant components consist of 12240 panels (450Wp) arranged in 15 series and 816 string solar panels, 51 DC combiner box 100 kW, 100 kW inverter, DC cable between solar panels to the inverter, AC cable between inverter to power grid type NYYHY, floater and mounting system made from HDPE and aluminum, deadweight anchor type, and mooring type loose capstan rope. The design shows a predicted system performance with a capacity factor of 18,61 , system efficiency of 17,51 , and a performance ratio of 83,75. © 2022 IEEE. 2022 Conference or Workshop Item PeerReviewed application/pdf en https://repository.ugm.ac.id/282148/1/Ananda%20et%20al%20-%202022%20-%20Preliminary_Design_of_Floating_Photovoltaic_at_The_Logung_Dam.pdf Ananda, Rifqi Firza and Budiarto, Rachmawan and Prabowo, Irawan Eko (2022) Preliminary Design of Floating Photovoltaic at The Logung Dam. In: International Conference on Technology and Policy in Energy and Electric Power (ICT-PEP) 2022. https://ieeexplore.ieee.org/document/9988940
spellingShingle Other Engineering
Engineering not elsewhere classified
Ananda, Rifqi Firza
Budiarto, Rachmawan
Prabowo, Irawan Eko
Preliminary Design of Floating Photovoltaic at The Logung Dam
title Preliminary Design of Floating Photovoltaic at The Logung Dam
title_full Preliminary Design of Floating Photovoltaic at The Logung Dam
title_fullStr Preliminary Design of Floating Photovoltaic at The Logung Dam
title_full_unstemmed Preliminary Design of Floating Photovoltaic at The Logung Dam
title_short Preliminary Design of Floating Photovoltaic at The Logung Dam
title_sort preliminary design of floating photovoltaic at the logung dam
topic Other Engineering
Engineering not elsewhere classified
url https://repository.ugm.ac.id/282148/1/Ananda%20et%20al%20-%202022%20-%20Preliminary_Design_of_Floating_Photovoltaic_at_The_Logung_Dam.pdf
work_keys_str_mv AT anandarifqifirza preliminarydesignoffloatingphotovoltaicatthelogungdam
AT budiartorachmawan preliminarydesignoffloatingphotovoltaicatthelogungdam
AT prabowoirawaneko preliminarydesignoffloatingphotovoltaicatthelogungdam