Low profile external fixation using locking compression plate as treatment option for management of soft tissue problem in open tibia fracture grade IIIA: A case series

Introduction: External fixators are the most common fixation method for fractures with substantial soft tissue compromise. Nonetheless, the frames used are bulky, uncomfortable, and cumbersome to patients. Using locking compression plate (LCP) as an external fixator (low profile external fixation/...

Full description

Bibliographic Details
Main Authors: Hidayat, Luthfi, Triangga, Aditya Fuad Robby, Cein, Caesarean Rayhan, Irfantian, Ardicho, Rahayu, Bernadeta Fuad Paramita, Resubun, Alan Philips, Magetsari, Rahadyan
Format: Article
Language:English
Published: Elsevier 2022
Subjects:
Online Access:https://repository.ugm.ac.id/283709/1/232.pdf
_version_ 1826050675144916992
author Hidayat, Luthfi
Triangga, Aditya Fuad Robby
Cein, Caesarean Rayhan
Irfantian, Ardicho
Rahayu, Bernadeta Fuad Paramita
Resubun, Alan Philips
Magetsari, Rahadyan
author_facet Hidayat, Luthfi
Triangga, Aditya Fuad Robby
Cein, Caesarean Rayhan
Irfantian, Ardicho
Rahayu, Bernadeta Fuad Paramita
Resubun, Alan Philips
Magetsari, Rahadyan
author_sort Hidayat, Luthfi
collection UGM
description Introduction: External fixators are the most common fixation method for fractures with substantial soft tissue compromise. Nonetheless, the frames used are bulky, uncomfortable, and cumbersome to patients. Using locking compression plate (LCP) as an external fixator (low profile external fixation/LPEF) owns the same properties as standard external fixators but may overcome disadvantages because of its low-profile frame. This case series aims to evaluate the results of LPEF for the management of tibia fracture with soft tissue compromise. Presentation of cases: We reviewed five patients at our centers who underwent surgery in 2020 with the appli- cation of LPEF. These patients had grade IIIA open tibia fracture with respective complications. The follow-up duration was 6 months post-operative in which we assessed Southampton Wound Assessment Scale (SWAS), laboratory infection markers, radiographic evaluation, and the Lower Extremity Functional Scale (LEFS). The results showed all wounds healed and cases with infection showed tendency of resolving, alongside varying degree of bone healing. The implant was well tolerated for patients and the functional outcome was overall good (mean LEFS: 71.26%). Discussion: The LPEF is fortuitously lightweight and more convenient for patients to ambulate, thus the compliance of early functional exercise is more likely to happen. Conclusion: Application of LPEF can be considered as an option for treating soft tissue compromised tibia fracture. In our experience, it is low profile, more acceptable to the patients, and displayed favorable outcomes especially in terms of soft tissue or skin healing and infection resolution.
first_indexed 2024-03-14T00:08:19Z
format Article
id oai:generic.eprints.org:283709
institution Universiti Gadjah Mada
language English
last_indexed 2024-03-14T00:08:19Z
publishDate 2022
publisher Elsevier
record_format dspace
spelling oai:generic.eprints.org:2837092023-11-22T03:14:01Z https://repository.ugm.ac.id/283709/ Low profile external fixation using locking compression plate as treatment option for management of soft tissue problem in open tibia fracture grade IIIA: A case series Hidayat, Luthfi Triangga, Aditya Fuad Robby Cein, Caesarean Rayhan Irfantian, Ardicho Rahayu, Bernadeta Fuad Paramita Resubun, Alan Philips Magetsari, Rahadyan Orthopaedics Introduction: External fixators are the most common fixation method for fractures with substantial soft tissue compromise. Nonetheless, the frames used are bulky, uncomfortable, and cumbersome to patients. Using locking compression plate (LCP) as an external fixator (low profile external fixation/LPEF) owns the same properties as standard external fixators but may overcome disadvantages because of its low-profile frame. This case series aims to evaluate the results of LPEF for the management of tibia fracture with soft tissue compromise. Presentation of cases: We reviewed five patients at our centers who underwent surgery in 2020 with the appli- cation of LPEF. These patients had grade IIIA open tibia fracture with respective complications. The follow-up duration was 6 months post-operative in which we assessed Southampton Wound Assessment Scale (SWAS), laboratory infection markers, radiographic evaluation, and the Lower Extremity Functional Scale (LEFS). The results showed all wounds healed and cases with infection showed tendency of resolving, alongside varying degree of bone healing. The implant was well tolerated for patients and the functional outcome was overall good (mean LEFS: 71.26%). Discussion: The LPEF is fortuitously lightweight and more convenient for patients to ambulate, thus the compliance of early functional exercise is more likely to happen. Conclusion: Application of LPEF can be considered as an option for treating soft tissue compromised tibia fracture. In our experience, it is low profile, more acceptable to the patients, and displayed favorable outcomes especially in terms of soft tissue or skin healing and infection resolution. Elsevier 2022-04 Article PeerReviewed application/pdf en https://repository.ugm.ac.id/283709/1/232.pdf Hidayat, Luthfi and Triangga, Aditya Fuad Robby and Cein, Caesarean Rayhan and Irfantian, Ardicho and Rahayu, Bernadeta Fuad Paramita and Resubun, Alan Philips and Magetsari, Rahadyan (2022) Low profile external fixation using locking compression plate as treatment option for management of soft tissue problem in open tibia fracture grade IIIA: A case series. International Journal of Surgery Case Reports, 93. p. 106882. ISSN 2210-2612 https://www.sciencedirect.com/science/article/pii/S2210261222001286 10.1016/j.ijscr.2022.106882
spellingShingle Orthopaedics
Hidayat, Luthfi
Triangga, Aditya Fuad Robby
Cein, Caesarean Rayhan
Irfantian, Ardicho
Rahayu, Bernadeta Fuad Paramita
Resubun, Alan Philips
Magetsari, Rahadyan
Low profile external fixation using locking compression plate as treatment option for management of soft tissue problem in open tibia fracture grade IIIA: A case series
title Low profile external fixation using locking compression plate as treatment option for management of soft tissue problem in open tibia fracture grade IIIA: A case series
title_full Low profile external fixation using locking compression plate as treatment option for management of soft tissue problem in open tibia fracture grade IIIA: A case series
title_fullStr Low profile external fixation using locking compression plate as treatment option for management of soft tissue problem in open tibia fracture grade IIIA: A case series
title_full_unstemmed Low profile external fixation using locking compression plate as treatment option for management of soft tissue problem in open tibia fracture grade IIIA: A case series
title_short Low profile external fixation using locking compression plate as treatment option for management of soft tissue problem in open tibia fracture grade IIIA: A case series
title_sort low profile external fixation using locking compression plate as treatment option for management of soft tissue problem in open tibia fracture grade iiia a case series
topic Orthopaedics
url https://repository.ugm.ac.id/283709/1/232.pdf
work_keys_str_mv AT hidayatluthfi lowprofileexternalfixationusinglockingcompressionplateastreatmentoptionformanagementofsofttissueprobleminopentibiafracturegradeiiiaacaseseries
AT trianggaadityafuadrobby lowprofileexternalfixationusinglockingcompressionplateastreatmentoptionformanagementofsofttissueprobleminopentibiafracturegradeiiiaacaseseries
AT ceincaesareanrayhan lowprofileexternalfixationusinglockingcompressionplateastreatmentoptionformanagementofsofttissueprobleminopentibiafracturegradeiiiaacaseseries
AT irfantianardicho lowprofileexternalfixationusinglockingcompressionplateastreatmentoptionformanagementofsofttissueprobleminopentibiafracturegradeiiiaacaseseries
AT rahayubernadetafuadparamita lowprofileexternalfixationusinglockingcompressionplateastreatmentoptionformanagementofsofttissueprobleminopentibiafracturegradeiiiaacaseseries
AT resubunalanphilips lowprofileexternalfixationusinglockingcompressionplateastreatmentoptionformanagementofsofttissueprobleminopentibiafracturegradeiiiaacaseseries
AT magetsarirahadyan lowprofileexternalfixationusinglockingcompressionplateastreatmentoptionformanagementofsofttissueprobleminopentibiafracturegradeiiiaacaseseries