Failure in power plant system related to mitigations and economic analysis; A study case from steam power plant in Suralaya, Indonesia
The failure mitigation and economic analysis related to the damage of the boiler tube in the power plant system were evaluated in the present study. The research was conducted at Indonesia's Suralaya power plant (PP). The boiler was built in 2011 and experienced a boiler tube failure after oper...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier B.V.
2023
|
Subjects: | |
Online Access: | https://repository.ugm.ac.id/285864/1/Failure%20in%20power%20plant%20system%20related%20to%20mitigations%20and%20economic%20analysis.pdf |
_version_ | 1797037893879857152 |
---|---|
author | Nugraha, Ariyana Dwiputra Harianto, Harianto Muflikhun, Muhammad Akhsin |
author_facet | Nugraha, Ariyana Dwiputra Harianto, Harianto Muflikhun, Muhammad Akhsin |
author_sort | Nugraha, Ariyana Dwiputra |
collection | UGM |
description | The failure mitigation and economic analysis related to the damage of the boiler tube in the power plant system were evaluated in the present study. The research was conducted at Indonesia's Suralaya power plant (PP). The boiler was built in 2011 and experienced a boiler tube failure after operating for less than 5 years. This condition is not common since boilers generally can be used with a lifetime of approximately 30 years. In the present study, different analyses were used i.e., macro-fractography, metallography inspection, hardness test, SEM/XRD analysis, and hydro test. These tests investigated the failure modes, evaluated the tube's mechanical properties, and assessed the boiler water feed's quality. The results showed that the damage is caused by the below-standard quality materials and is triggered by the poor quality of boiler feed water and exhibit corrosion. It is proven that the high value of sodium, conductivity, and silica content causes corrosion of the inner tube, which came out from methane gas. It is also shown that the damage drastically decreased the quality of the water wall tube strength, indicated by the HRV value from 179 HRV to 112 HRV. The analysis was a brief study that can be used for manufacturers and industries that use the boiler to check the material quality and the detailed specification. Moreover, the below-standard materials have proven to cause economic loss and burden many sectors' maintenance and operation costs. |
first_indexed | 2024-03-14T00:11:02Z |
format | Article |
id | oai:generic.eprints.org:285864 |
institution | Universiti Gadjah Mada |
language | English |
last_indexed | 2024-03-14T00:11:02Z |
publishDate | 2023 |
publisher | Elsevier B.V. |
record_format | dspace |
spelling | oai:generic.eprints.org:2858642024-03-04T08:01:06Z https://repository.ugm.ac.id/285864/ Failure in power plant system related to mitigations and economic analysis; A study case from steam power plant in Suralaya, Indonesia Nugraha, Ariyana Dwiputra Harianto, Harianto Muflikhun, Muhammad Akhsin Mechanical Engineering not elsewhere classified The failure mitigation and economic analysis related to the damage of the boiler tube in the power plant system were evaluated in the present study. The research was conducted at Indonesia's Suralaya power plant (PP). The boiler was built in 2011 and experienced a boiler tube failure after operating for less than 5 years. This condition is not common since boilers generally can be used with a lifetime of approximately 30 years. In the present study, different analyses were used i.e., macro-fractography, metallography inspection, hardness test, SEM/XRD analysis, and hydro test. These tests investigated the failure modes, evaluated the tube's mechanical properties, and assessed the boiler water feed's quality. The results showed that the damage is caused by the below-standard quality materials and is triggered by the poor quality of boiler feed water and exhibit corrosion. It is proven that the high value of sodium, conductivity, and silica content causes corrosion of the inner tube, which came out from methane gas. It is also shown that the damage drastically decreased the quality of the water wall tube strength, indicated by the HRV value from 179 HRV to 112 HRV. The analysis was a brief study that can be used for manufacturers and industries that use the boiler to check the material quality and the detailed specification. Moreover, the below-standard materials have proven to cause economic loss and burden many sectors' maintenance and operation costs. Elsevier B.V. 2023 Article PeerReviewed application/pdf en https://repository.ugm.ac.id/285864/1/Failure%20in%20power%20plant%20system%20related%20to%20mitigations%20and%20economic%20analysis.pdf Nugraha, Ariyana Dwiputra and Harianto, Harianto and Muflikhun, Muhammad Akhsin (2023) Failure in power plant system related to mitigations and economic analysis; A study case from steam power plant in Suralaya, Indonesia. Results in Engineering, 17 (101004). pp. 1-11. ISSN 25901230 https://www.sciencedirect.com/science/article/pii/S2590123023001317?via=ihub 10.1016/j.rineng.2023.101004 |
spellingShingle | Mechanical Engineering not elsewhere classified Nugraha, Ariyana Dwiputra Harianto, Harianto Muflikhun, Muhammad Akhsin Failure in power plant system related to mitigations and economic analysis; A study case from steam power plant in Suralaya, Indonesia |
title | Failure in power plant system related to mitigations and economic analysis; A study case from steam power plant in Suralaya, Indonesia |
title_full | Failure in power plant system related to mitigations and economic analysis; A study case from steam power plant in Suralaya, Indonesia |
title_fullStr | Failure in power plant system related to mitigations and economic analysis; A study case from steam power plant in Suralaya, Indonesia |
title_full_unstemmed | Failure in power plant system related to mitigations and economic analysis; A study case from steam power plant in Suralaya, Indonesia |
title_short | Failure in power plant system related to mitigations and economic analysis; A study case from steam power plant in Suralaya, Indonesia |
title_sort | failure in power plant system related to mitigations and economic analysis a study case from steam power plant in suralaya indonesia |
topic | Mechanical Engineering not elsewhere classified |
url | https://repository.ugm.ac.id/285864/1/Failure%20in%20power%20plant%20system%20related%20to%20mitigations%20and%20economic%20analysis.pdf |
work_keys_str_mv | AT nugrahaariyanadwiputra failureinpowerplantsystemrelatedtomitigationsandeconomicanalysisastudycasefromsteampowerplantinsuralayaindonesia AT hariantoharianto failureinpowerplantsystemrelatedtomitigationsandeconomicanalysisastudycasefromsteampowerplantinsuralayaindonesia AT muflikhunmuhammadakhsin failureinpowerplantsystemrelatedtomitigationsandeconomicanalysisastudycasefromsteampowerplantinsuralayaindonesia |