Method of measuring doppler shift of moving targets using FMCW maritime radar

During the operation of an FMCW (frequency modulated continuous wave) maritime radar, the system transmits a continuous radio energy with a frequency modulated by a triangular or sawtooth-shaped signal. As a result, the frequency of the transmitted signal varies gradually with time. When the signal...

Full description

Bibliographic Details
Main Author: Sediono, Wahju
Format: Proceeding Paper
Language:English
Published: 2013
Subjects:
Online Access:http://irep.iium.edu.my/31730/1/p.tale.2013.wsediono.Contribution230_b.pdf
_version_ 1825647441656938496
author Sediono, Wahju
author_facet Sediono, Wahju
author_sort Sediono, Wahju
collection IIUM
description During the operation of an FMCW (frequency modulated continuous wave) maritime radar, the system transmits a continuous radio energy with a frequency modulated by a triangular or sawtooth-shaped signal. As a result, the frequency of the transmitted signal varies gradually with time. When the signal is reflected by an object, the received waveform will build up a delayed replica of the transmitted waveform, with the time delay as a measure of the target range. If the target is moving, the radar system will register a Doppler shift within the received signal. Compared to the frequency of the emitted signal, the received signal will show a higher frequency when the target is approaching and a lower frequency when the target is moving away from the radar location. Thus, the total Doppler shift may result from the superposition of both source and observer motions. Specifically, the amount of Doppler shift is directly proportional to the radial speed of the target. The Doppler shift can be determined after performing the range Fourier transform (range FFT) first. For a target of interest, we can repeat the range FFT until we have enough data to perform the second level of FFT. The result of this second FFT is a two dimensional complex valued matrix, whose spectral peak corresponds to the Doppler shift of the moving target. This method is known as Doppler FFT. Some results of the measurement of target speed using this method are presented in this paper.
first_indexed 2024-03-05T23:17:39Z
format Proceeding Paper
id oai:generic.eprints.org:31730
institution International Islamic University Malaysia
language English
last_indexed 2024-03-05T23:17:39Z
publishDate 2013
record_format dspace
spelling oai:generic.eprints.org:317302015-03-20T07:23:50Z http://irep.iium.edu.my/31730/ Method of measuring doppler shift of moving targets using FMCW maritime radar Sediono, Wahju TK7885 Computer engineering During the operation of an FMCW (frequency modulated continuous wave) maritime radar, the system transmits a continuous radio energy with a frequency modulated by a triangular or sawtooth-shaped signal. As a result, the frequency of the transmitted signal varies gradually with time. When the signal is reflected by an object, the received waveform will build up a delayed replica of the transmitted waveform, with the time delay as a measure of the target range. If the target is moving, the radar system will register a Doppler shift within the received signal. Compared to the frequency of the emitted signal, the received signal will show a higher frequency when the target is approaching and a lower frequency when the target is moving away from the radar location. Thus, the total Doppler shift may result from the superposition of both source and observer motions. Specifically, the amount of Doppler shift is directly proportional to the radial speed of the target. The Doppler shift can be determined after performing the range Fourier transform (range FFT) first. For a target of interest, we can repeat the range FFT until we have enough data to perform the second level of FFT. The result of this second FFT is a two dimensional complex valued matrix, whose spectral peak corresponds to the Doppler shift of the moving target. This method is known as Doppler FFT. Some results of the measurement of target speed using this method are presented in this paper. 2013 Proceeding Paper PeerReviewed application/pdf en http://irep.iium.edu.my/31730/1/p.tale.2013.wsediono.Contribution230_b.pdf Sediono, Wahju (2013) Method of measuring doppler shift of moving targets using FMCW maritime radar. In: IEEE International Conference on Teaching, Assessment and Learning for Engineering (TALE) 2013, 26-29 August 2013, Denpasar-Bali, Indonesia. http://www.tale-conference.org/tale2013/
spellingShingle TK7885 Computer engineering
Sediono, Wahju
Method of measuring doppler shift of moving targets using FMCW maritime radar
title Method of measuring doppler shift of moving targets using FMCW maritime radar
title_full Method of measuring doppler shift of moving targets using FMCW maritime radar
title_fullStr Method of measuring doppler shift of moving targets using FMCW maritime radar
title_full_unstemmed Method of measuring doppler shift of moving targets using FMCW maritime radar
title_short Method of measuring doppler shift of moving targets using FMCW maritime radar
title_sort method of measuring doppler shift of moving targets using fmcw maritime radar
topic TK7885 Computer engineering
url http://irep.iium.edu.my/31730/1/p.tale.2013.wsediono.Contribution230_b.pdf
work_keys_str_mv AT sedionowahju methodofmeasuringdopplershiftofmovingtargetsusingfmcwmaritimeradar