Experimental study on the influence of the porosity of parallel plate stack on the temperature decrease of a thermoacoustic refrigerator

Thermoacoustic refrigerators are cooling devices which are environmentally friendly because they don't use hazardous gases like chlorofuorcarbons (CFCs) or hydrofourocarbons (HFCs) but rather air or or inert gases as working meium. They apply sound resonator tube. One of the important parameter...

Full description

Bibliographic Details
Main Authors: Setiawan, Ikhsan, Utomo, Agung Bambang Setio, Mitrayana, ., Katsuta, Masafumi, Nohtomi, Makoto
Format: Article
Language:English
Published: IOP Publishing Ltd 2013
Subjects:
Online Access:https://repository.ugm.ac.id/33061/1/experimental_study_on_the_influence_of_the_porosity_of_parallel_plate_stachk_on_the_temperature_decrease_of_a_thermoacoustic_refrigerator.pdf
_version_ 1797020218457849856
author Setiawan, Ikhsan
Utomo, Agung Bambang Setio
Mitrayana, .
Katsuta, Masafumi
Nohtomi, Makoto
author_facet Setiawan, Ikhsan
Utomo, Agung Bambang Setio
Mitrayana, .
Katsuta, Masafumi
Nohtomi, Makoto
author_sort Setiawan, Ikhsan
collection UGM
description Thermoacoustic refrigerators are cooling devices which are environmentally friendly because they don't use hazardous gases like chlorofuorcarbons (CFCs) or hydrofourocarbons (HFCs) but rather air or or inert gases as working meium. They apply sound resonator tube. One of the important parameters of themoacoustic refrigerators is the porosity (blockage ratio) of stack which is a fraction of cross sectional area of the resonator unblocked for the gas movement by the stack. This paper describes an experimental study on how the porosity of parallel plate stack affects the temperature decrease of a thermoacoustic refrigerator. The porosity of parallel plate stack is specified by the thickness of plates and the spacing between plates. We measured the maximum temperature decreases of thermoacoustic refrigerator usig stacks with various porosities in the range of 0.5 - 0.85, with plate spacing from 0.5 mm to 1.5 mm and plate thicknesses 0.3 mm, 0.4 mm, and 0.5 mm. The measurements were done with two resonators with length of 0.8 m and 1.0 m, with air at atmospheric pressure and room temperature, correspond to thermal penetration depths of 0.26 mm and 0.29 mm, respectively. It was found that there is an optimum porosity which gives the larger value and the temperature decrease become larger when we used a stack with thinner plates. On the other hand, the study on the dependence of the temperature decrease on the plate thickness and the plate spacing reveals more useful information than that on the stack porosity itself. We found that stack with thinner plates tends to give larger temperature decrease, and the plate spacing of around 4 leads to the largest temperature decrease.
first_indexed 2024-03-13T19:12:38Z
format Article
id oai:generic.eprints.org:33061
institution Universiti Gadjah Mada
language English
last_indexed 2024-03-13T19:12:38Z
publishDate 2013
publisher IOP Publishing Ltd
record_format dspace
spelling oai:generic.eprints.org:330612016-02-19T03:53:47Z https://repository.ugm.ac.id/33061/ Experimental study on the influence of the porosity of parallel plate stack on the temperature decrease of a thermoacoustic refrigerator Setiawan, Ikhsan Utomo, Agung Bambang Setio Mitrayana, . Katsuta, Masafumi Nohtomi, Makoto Acoustics and Acoustical Devices; Waves Thermodynamics and Statistical Physics Thermoacoustic refrigerators are cooling devices which are environmentally friendly because they don't use hazardous gases like chlorofuorcarbons (CFCs) or hydrofourocarbons (HFCs) but rather air or or inert gases as working meium. They apply sound resonator tube. One of the important parameters of themoacoustic refrigerators is the porosity (blockage ratio) of stack which is a fraction of cross sectional area of the resonator unblocked for the gas movement by the stack. This paper describes an experimental study on how the porosity of parallel plate stack affects the temperature decrease of a thermoacoustic refrigerator. The porosity of parallel plate stack is specified by the thickness of plates and the spacing between plates. We measured the maximum temperature decreases of thermoacoustic refrigerator usig stacks with various porosities in the range of 0.5 - 0.85, with plate spacing from 0.5 mm to 1.5 mm and plate thicknesses 0.3 mm, 0.4 mm, and 0.5 mm. The measurements were done with two resonators with length of 0.8 m and 1.0 m, with air at atmospheric pressure and room temperature, correspond to thermal penetration depths of 0.26 mm and 0.29 mm, respectively. It was found that there is an optimum porosity which gives the larger value and the temperature decrease become larger when we used a stack with thinner plates. On the other hand, the study on the dependence of the temperature decrease on the plate thickness and the plate spacing reveals more useful information than that on the stack porosity itself. We found that stack with thinner plates tends to give larger temperature decrease, and the plate spacing of around 4 leads to the largest temperature decrease. IOP Publishing Ltd 2013-04-10 Article PeerReviewed application/pdf en https://repository.ugm.ac.id/33061/1/experimental_study_on_the_influence_of_the_porosity_of_parallel_plate_stachk_on_the_temperature_decrease_of_a_thermoacoustic_refrigerator.pdf Setiawan, Ikhsan and Utomo, Agung Bambang Setio and Mitrayana, . and Katsuta, Masafumi and Nohtomi, Makoto (2013) Experimental study on the influence of the porosity of parallel plate stack on the temperature decrease of a thermoacoustic refrigerator. IOP Science Journal of Physics: Conference Series 423 (2013) 012035, 423 (012035). pp. 1-6. ISSN doi:10.1088/1742-6596/423/1/012035 http://iopscience.iop.org/1742-6596/423/1/012035 133.9.4.12
spellingShingle Acoustics and Acoustical Devices; Waves
Thermodynamics and Statistical Physics
Setiawan, Ikhsan
Utomo, Agung Bambang Setio
Mitrayana, .
Katsuta, Masafumi
Nohtomi, Makoto
Experimental study on the influence of the porosity of parallel plate stack on the temperature decrease of a thermoacoustic refrigerator
title Experimental study on the influence of the porosity of parallel plate stack on the temperature decrease of a thermoacoustic refrigerator
title_full Experimental study on the influence of the porosity of parallel plate stack on the temperature decrease of a thermoacoustic refrigerator
title_fullStr Experimental study on the influence of the porosity of parallel plate stack on the temperature decrease of a thermoacoustic refrigerator
title_full_unstemmed Experimental study on the influence of the porosity of parallel plate stack on the temperature decrease of a thermoacoustic refrigerator
title_short Experimental study on the influence of the porosity of parallel plate stack on the temperature decrease of a thermoacoustic refrigerator
title_sort experimental study on the influence of the porosity of parallel plate stack on the temperature decrease of a thermoacoustic refrigerator
topic Acoustics and Acoustical Devices; Waves
Thermodynamics and Statistical Physics
url https://repository.ugm.ac.id/33061/1/experimental_study_on_the_influence_of_the_porosity_of_parallel_plate_stachk_on_the_temperature_decrease_of_a_thermoacoustic_refrigerator.pdf
work_keys_str_mv AT setiawanikhsan experimentalstudyontheinfluenceoftheporosityofparallelplatestackonthetemperaturedecreaseofathermoacousticrefrigerator
AT utomoagungbambangsetio experimentalstudyontheinfluenceoftheporosityofparallelplatestackonthetemperaturedecreaseofathermoacousticrefrigerator
AT mitrayana experimentalstudyontheinfluenceoftheporosityofparallelplatestackonthetemperaturedecreaseofathermoacousticrefrigerator
AT katsutamasafumi experimentalstudyontheinfluenceoftheporosityofparallelplatestackonthetemperaturedecreaseofathermoacousticrefrigerator
AT nohtomimakoto experimentalstudyontheinfluenceoftheporosityofparallelplatestackonthetemperaturedecreaseofathermoacousticrefrigerator