Gram negative infection following plating of Tibia resulted with exposed bone and implant

We report four cases of gram negative infection following plating of the tibia that resulted in expose bone and metal implant which were treated in our center from March 2003 till December 2008. The incidence of Gram negative implant related infection is increasing and probably has poorer outcome. T...

Full description

Bibliographic Details
Main Authors: Mohd Yusof, Nazri, Zulkifly, Ahmad Hafiz, Zakaria@Mohamad, Zamzuri, Che Ahmad, Aminudin, Mohammad Amin, Mohammad Azril, Awang, Mohd Shukrimi
Format: Proceeding Paper
Language:English
English
Published: 2011
Subjects:
Online Access:http://irep.iium.edu.my/8463/1/certificate_poster_presentation.pdf
http://irep.iium.edu.my/8463/2/Abstract_Book_-_E-posters.pdf
_version_ 1825645023251660800
author Mohd Yusof, Nazri
Zulkifly, Ahmad Hafiz
Zakaria@Mohamad, Zamzuri
Che Ahmad, Aminudin
Mohammad Amin, Mohammad Azril
Awang, Mohd Shukrimi
author_facet Mohd Yusof, Nazri
Zulkifly, Ahmad Hafiz
Zakaria@Mohamad, Zamzuri
Che Ahmad, Aminudin
Mohammad Amin, Mohammad Azril
Awang, Mohd Shukrimi
author_sort Mohd Yusof, Nazri
collection IIUM
description We report four cases of gram negative infection following plating of the tibia that resulted in expose bone and metal implant which were treated in our center from March 2003 till December 2008. The incidence of Gram negative implant related infection is increasing and probably has poorer outcome. Treatment of this condition requires both bone and soft tissue reconstruction technique that is done in three stages (debridement, soft tissue reconstruction and bone reconstruction). All patient achieved union at the end of follow up.The mean union time is 9.25 months (ranges from 6 to 12 months) after the injury. At the end of follow up, only one patient had persistent infection but able to ambulate normally following fracture union).
first_indexed 2024-03-05T22:41:30Z
format Proceeding Paper
id oai:generic.eprints.org:8463
institution International Islamic University Malaysia
language English
English
last_indexed 2024-03-05T22:41:30Z
publishDate 2011
record_format dspace
spelling oai:generic.eprints.org:84632015-03-11T06:28:21Z http://irep.iium.edu.my/8463/ Gram negative infection following plating of Tibia resulted with exposed bone and implant Mohd Yusof, Nazri Zulkifly, Ahmad Hafiz Zakaria@Mohamad, Zamzuri Che Ahmad, Aminudin Mohammad Amin, Mohammad Azril Awang, Mohd Shukrimi RJ Pediatrics We report four cases of gram negative infection following plating of the tibia that resulted in expose bone and metal implant which were treated in our center from March 2003 till December 2008. The incidence of Gram negative implant related infection is increasing and probably has poorer outcome. Treatment of this condition requires both bone and soft tissue reconstruction technique that is done in three stages (debridement, soft tissue reconstruction and bone reconstruction). All patient achieved union at the end of follow up.The mean union time is 9.25 months (ranges from 6 to 12 months) after the injury. At the end of follow up, only one patient had persistent infection but able to ambulate normally following fracture union). 2011 Proceeding Paper NonPeerReviewed application/pdf en http://irep.iium.edu.my/8463/1/certificate_poster_presentation.pdf application/pdf en http://irep.iium.edu.my/8463/2/Abstract_Book_-_E-posters.pdf Mohd Yusof, Nazri and Zulkifly, Ahmad Hafiz and Zakaria@Mohamad, Zamzuri and Che Ahmad, Aminudin and Mohammad Amin, Mohammad Azril and Awang, Mohd Shukrimi (2011) Gram negative infection following plating of Tibia resulted with exposed bone and implant. In: SICOT 2011 XXV Triennial World Congress, 6-9 September 2011, Prague, Czech republic. (Unpublished) http://www.sicot.org/?id_page=325
spellingShingle RJ Pediatrics
Mohd Yusof, Nazri
Zulkifly, Ahmad Hafiz
Zakaria@Mohamad, Zamzuri
Che Ahmad, Aminudin
Mohammad Amin, Mohammad Azril
Awang, Mohd Shukrimi
Gram negative infection following plating of Tibia resulted with exposed bone and implant
title Gram negative infection following plating of Tibia resulted with exposed bone and implant
title_full Gram negative infection following plating of Tibia resulted with exposed bone and implant
title_fullStr Gram negative infection following plating of Tibia resulted with exposed bone and implant
title_full_unstemmed Gram negative infection following plating of Tibia resulted with exposed bone and implant
title_short Gram negative infection following plating of Tibia resulted with exposed bone and implant
title_sort gram negative infection following plating of tibia resulted with exposed bone and implant
topic RJ Pediatrics
url http://irep.iium.edu.my/8463/1/certificate_poster_presentation.pdf
http://irep.iium.edu.my/8463/2/Abstract_Book_-_E-posters.pdf
work_keys_str_mv AT mohdyusofnazri gramnegativeinfectionfollowingplatingoftibiaresultedwithexposedboneandimplant
AT zulkiflyahmadhafiz gramnegativeinfectionfollowingplatingoftibiaresultedwithexposedboneandimplant
AT zakariamohamadzamzuri gramnegativeinfectionfollowingplatingoftibiaresultedwithexposedboneandimplant
AT cheahmadaminudin gramnegativeinfectionfollowingplatingoftibiaresultedwithexposedboneandimplant
AT mohammadaminmohammadazril gramnegativeinfectionfollowingplatingoftibiaresultedwithexposedboneandimplant
AT awangmohdshukrimi gramnegativeinfectionfollowingplatingoftibiaresultedwithexposedboneandimplant