ANALISIS BANDWIDTH PADA LAN DENGAN DATA TERINTEGRASI POWERLINEMENGGUNAKAN KABEL CAT 5E (STANDARD 100BASE-TX)

Power over Ethernet (PoE) started to develop in the year 2000 along with the development of VoIP, and Wireless LAN. Regarding the power supply, the same as analog telephone, VoIP uses centralized power source for the operation. WLAN needs flexible power source for the operation. IEEE immediately rel...

Full description

Bibliographic Details
Main Authors: , Joko Witarto, , Dr. Ir. Eko Nugroho, M.Si.
Format: Thesis
Published: [Yogyakarta] : Universitas Gadjah Mada 2011
Subjects:
ETD
_version_ 1797030309538037760
author , Joko Witarto
, Dr. Ir. Eko Nugroho, M.Si.
author_facet , Joko Witarto
, Dr. Ir. Eko Nugroho, M.Si.
author_sort , Joko Witarto
collection UGM
description Power over Ethernet (PoE) started to develop in the year 2000 along with the development of VoIP, and Wireless LAN. Regarding the power supply, the same as analog telephone, VoIP uses centralized power source for the operation. WLAN needs flexible power source for the operation. IEEE immediately released the standard for power source distribution by means of cable for this need, that is IEEE 802.3af. The electric power provided based on this standard is 13 watt on a 48 volt DC voltage. In this research, 220 volt AC voltage and 50 Hz frequency were used, so that the electric power could reach 300 watt. Since the voltage used 220 volt AC, a feasibility test was carried out towards the Cat 5E cable for 220 volt AC voltage. Bandwidth measurement was conducted to find out the effect of 50 Hz frequency interference to the data package sent through Cat 5E cable. The load in this research was inductive load, capacitive load, and resistive load. The result of research shows that Cat 5E cable is adequate to be given 220 volt AC voltage with maximum load in accordance with the wire capacity. 50 Hz frequency of PLN (State Electricity Company) that is used does not affect on the data communication.
first_indexed 2024-03-13T22:03:38Z
format Thesis
id oai:generic.eprints.org:88343
institution Universiti Gadjah Mada
last_indexed 2024-03-13T22:03:38Z
publishDate 2011
publisher [Yogyakarta] : Universitas Gadjah Mada
record_format dspace
spelling oai:generic.eprints.org:883432014-08-20T02:52:13Z https://repository.ugm.ac.id/88343/ ANALISIS BANDWIDTH PADA LAN DENGAN DATA TERINTEGRASI POWERLINEMENGGUNAKAN KABEL CAT 5E (STANDARD 100BASE-TX) , Joko Witarto , Dr. Ir. Eko Nugroho, M.Si. ETD Power over Ethernet (PoE) started to develop in the year 2000 along with the development of VoIP, and Wireless LAN. Regarding the power supply, the same as analog telephone, VoIP uses centralized power source for the operation. WLAN needs flexible power source for the operation. IEEE immediately released the standard for power source distribution by means of cable for this need, that is IEEE 802.3af. The electric power provided based on this standard is 13 watt on a 48 volt DC voltage. In this research, 220 volt AC voltage and 50 Hz frequency were used, so that the electric power could reach 300 watt. Since the voltage used 220 volt AC, a feasibility test was carried out towards the Cat 5E cable for 220 volt AC voltage. Bandwidth measurement was conducted to find out the effect of 50 Hz frequency interference to the data package sent through Cat 5E cable. The load in this research was inductive load, capacitive load, and resistive load. The result of research shows that Cat 5E cable is adequate to be given 220 volt AC voltage with maximum load in accordance with the wire capacity. 50 Hz frequency of PLN (State Electricity Company) that is used does not affect on the data communication. [Yogyakarta] : Universitas Gadjah Mada 2011 Thesis NonPeerReviewed , Joko Witarto and , Dr. Ir. Eko Nugroho, M.Si. (2011) ANALISIS BANDWIDTH PADA LAN DENGAN DATA TERINTEGRASI POWERLINEMENGGUNAKAN KABEL CAT 5E (STANDARD 100BASE-TX). UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=50556
spellingShingle ETD
, Joko Witarto
, Dr. Ir. Eko Nugroho, M.Si.
ANALISIS BANDWIDTH PADA LAN DENGAN DATA TERINTEGRASI POWERLINEMENGGUNAKAN KABEL CAT 5E (STANDARD 100BASE-TX)
title ANALISIS BANDWIDTH PADA LAN DENGAN DATA TERINTEGRASI POWERLINEMENGGUNAKAN KABEL CAT 5E (STANDARD 100BASE-TX)
title_full ANALISIS BANDWIDTH PADA LAN DENGAN DATA TERINTEGRASI POWERLINEMENGGUNAKAN KABEL CAT 5E (STANDARD 100BASE-TX)
title_fullStr ANALISIS BANDWIDTH PADA LAN DENGAN DATA TERINTEGRASI POWERLINEMENGGUNAKAN KABEL CAT 5E (STANDARD 100BASE-TX)
title_full_unstemmed ANALISIS BANDWIDTH PADA LAN DENGAN DATA TERINTEGRASI POWERLINEMENGGUNAKAN KABEL CAT 5E (STANDARD 100BASE-TX)
title_short ANALISIS BANDWIDTH PADA LAN DENGAN DATA TERINTEGRASI POWERLINEMENGGUNAKAN KABEL CAT 5E (STANDARD 100BASE-TX)
title_sort analisis bandwidth pada lan dengan data terintegrasi powerlinemenggunakan kabel cat 5e standard 100base tx
topic ETD
work_keys_str_mv AT jokowitarto analisisbandwidthpadalandengandataterintegrasipowerlinemenggunakankabelcat5estandard100basetx
AT drirekonugrohomsi analisisbandwidthpadalandengandataterintegrasipowerlinemenggunakankabelcat5estandard100basetx