PENGGUNAAN BETON STYROFOAM DENGAN PERKUATAN WIREMESH UNTUK PANEL DINDING TEBAL 7 CM

The recent technology of building material for walls, is getting toward to the use of walls that have some characters such as light, fast assembled and environmentally friendly. Making lightweight concrete wall from styrofoam waste is an effort to take advantage of styrofoam waste. Styrofoam has a v...

Full description

Bibliographic Details
Main Authors: , Andi Prasetiyo Wibowo, , Ir. Suprapto Siswosukarto, Ph.D.
Format: Thesis
Published: [Yogyakarta] : Universitas Gadjah Mada 2011
Subjects:
ETD
_version_ 1826043784028225536
author , Andi Prasetiyo Wibowo
, Ir. Suprapto Siswosukarto, Ph.D.
author_facet , Andi Prasetiyo Wibowo
, Ir. Suprapto Siswosukarto, Ph.D.
author_sort , Andi Prasetiyo Wibowo
collection UGM
description The recent technology of building material for walls, is getting toward to the use of walls that have some characters such as light, fast assembled and environmentally friendly. Making lightweight concrete wall from styrofoam waste is an effort to take advantage of styrofoam waste. Styrofoam has a very light weight unit that is about 13 to 15 kg/m 3 . The use wiremesh layers aimed to reinforce the walls. The research for styrofoam concrete wall panel used 12 specimens of panel, 1000 mm length, 300 mm width and 70 mm thick, with the addition of 15 mm thick layer of plaster / mortar on both sides. The composition of 1 m 3 concrete styrofoam consisted of 300 kg cement, using 0,5 water cement ratio, and styrofoam and sand ratio of 60% : 40%. The specimens of panels as follows : 3 pieces without reinforcement wiremesh, and 9 with wiremesh reinforcement having connector space variations : 150, 250, 350 mm. There were 3 specimens for each of these connector spacing variation. Test conducted was bending test. The results of the research showed that concrete material made from styrofoam had the average value of compressive strength : 3,348 MPa, weight: 1.510,86 kg / m 3 , and modulus of elasticity : 330,24 MPa. On the other hand, the mortar material had the average value of compressive strength: 36,586 MPa in average, and weight: 2.155,70 kg/m 3 . The average water-absorption of concrete made from styrofoam was 11,97%. The average water-absorption of mortar was 10,77%. The weight of the panel without wiremesh before plastered was 97.98 kg/m 2 , and 164,15 kg/m 2 after plastered. Whereas the panel with wiremesh, before plastered 105,23 kg/m 2 , and after the plastered had weight 170,12 kg/m 2 . Largest panel flexural strength was obtained by the panel 2.A with flexural strength values of 6,64 MPa. The results also showed that wiremesh reinforcement and the closer the connector space, increased flexural strength of the panel.
first_indexed 2024-03-13T22:09:13Z
format Thesis
id oai:generic.eprints.org:90057
institution Universiti Gadjah Mada
last_indexed 2024-03-13T22:09:13Z
publishDate 2011
publisher [Yogyakarta] : Universitas Gadjah Mada
record_format dspace
spelling oai:generic.eprints.org:900572014-08-20T02:50:20Z https://repository.ugm.ac.id/90057/ PENGGUNAAN BETON STYROFOAM DENGAN PERKUATAN WIREMESH UNTUK PANEL DINDING TEBAL 7 CM , Andi Prasetiyo Wibowo , Ir. Suprapto Siswosukarto, Ph.D. ETD The recent technology of building material for walls, is getting toward to the use of walls that have some characters such as light, fast assembled and environmentally friendly. Making lightweight concrete wall from styrofoam waste is an effort to take advantage of styrofoam waste. Styrofoam has a very light weight unit that is about 13 to 15 kg/m 3 . The use wiremesh layers aimed to reinforce the walls. The research for styrofoam concrete wall panel used 12 specimens of panel, 1000 mm length, 300 mm width and 70 mm thick, with the addition of 15 mm thick layer of plaster / mortar on both sides. The composition of 1 m 3 concrete styrofoam consisted of 300 kg cement, using 0,5 water cement ratio, and styrofoam and sand ratio of 60% : 40%. The specimens of panels as follows : 3 pieces without reinforcement wiremesh, and 9 with wiremesh reinforcement having connector space variations : 150, 250, 350 mm. There were 3 specimens for each of these connector spacing variation. Test conducted was bending test. The results of the research showed that concrete material made from styrofoam had the average value of compressive strength : 3,348 MPa, weight: 1.510,86 kg / m 3 , and modulus of elasticity : 330,24 MPa. On the other hand, the mortar material had the average value of compressive strength: 36,586 MPa in average, and weight: 2.155,70 kg/m 3 . The average water-absorption of concrete made from styrofoam was 11,97%. The average water-absorption of mortar was 10,77%. The weight of the panel without wiremesh before plastered was 97.98 kg/m 2 , and 164,15 kg/m 2 after plastered. Whereas the panel with wiremesh, before plastered 105,23 kg/m 2 , and after the plastered had weight 170,12 kg/m 2 . Largest panel flexural strength was obtained by the panel 2.A with flexural strength values of 6,64 MPa. The results also showed that wiremesh reinforcement and the closer the connector space, increased flexural strength of the panel. [Yogyakarta] : Universitas Gadjah Mada 2011 Thesis NonPeerReviewed , Andi Prasetiyo Wibowo and , Ir. Suprapto Siswosukarto, Ph.D. (2011) PENGGUNAAN BETON STYROFOAM DENGAN PERKUATAN WIREMESH UNTUK PANEL DINDING TEBAL 7 CM. UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=50415
spellingShingle ETD
, Andi Prasetiyo Wibowo
, Ir. Suprapto Siswosukarto, Ph.D.
PENGGUNAAN BETON STYROFOAM DENGAN PERKUATAN WIREMESH UNTUK PANEL DINDING TEBAL 7 CM
title PENGGUNAAN BETON STYROFOAM DENGAN PERKUATAN WIREMESH UNTUK PANEL DINDING TEBAL 7 CM
title_full PENGGUNAAN BETON STYROFOAM DENGAN PERKUATAN WIREMESH UNTUK PANEL DINDING TEBAL 7 CM
title_fullStr PENGGUNAAN BETON STYROFOAM DENGAN PERKUATAN WIREMESH UNTUK PANEL DINDING TEBAL 7 CM
title_full_unstemmed PENGGUNAAN BETON STYROFOAM DENGAN PERKUATAN WIREMESH UNTUK PANEL DINDING TEBAL 7 CM
title_short PENGGUNAAN BETON STYROFOAM DENGAN PERKUATAN WIREMESH UNTUK PANEL DINDING TEBAL 7 CM
title_sort penggunaan beton styrofoam dengan perkuatan wiremesh untuk panel dinding tebal 7 cm
topic ETD
work_keys_str_mv AT andiprasetiyowibowo penggunaanbetonstyrofoamdenganperkuatanwiremeshuntukpaneldindingtebal7cm
AT irsupraptosiswosukartophd penggunaanbetonstyrofoamdenganperkuatanwiremeshuntukpaneldindingtebal7cm