OPTIMALISASI DAN RANCANGAN SISTEM PROTEKSI PENUTUP BALIK OTOMATIS (RECLOSER) JARINGAN DISTRIBUSI LISTRIK 1 FASE DAYA 3KW PADA PLTMh SINGOSAREN WUKIRSARI IMOGIRI BANTUL YOGYAKARTA (Berbasis Mikrokontroler ATmega16)

MHP began many built in several areas but to obtain security comfort electrically to the load-more (overload) or other disorders that are still desperately needed extreme protective equipment that can prevent damage to the generator so that the continuity of electricity distribution services is well...

Full description

Bibliographic Details
Main Authors: , IMAM SYAFI'I, , Prof.(Emr). Adhi Susanto, M.Sc., Ph.D.
Format: Thesis
Published: [Yogyakarta] : Universitas Gadjah Mada 2011
Subjects:
ETD
_version_ 1826043788367233024
author , IMAM SYAFI'I
, Prof.(Emr). Adhi Susanto, M.Sc., Ph.D.
author_facet , IMAM SYAFI'I
, Prof.(Emr). Adhi Susanto, M.Sc., Ph.D.
author_sort , IMAM SYAFI'I
collection UGM
description MHP began many built in several areas but to obtain security comfort electrically to the load-more (overload) or other disorders that are still desperately needed extreme protective equipment that can prevent damage to the generator so that the continuity of electricity distribution services is well maintained and reliable. The purpose of this research is to design and construct a protection device (recloser) (Safety equipment impaired overload is automatically opened and closed electrical circuit) programmed with ATmega16 microcontroller in electricity distribution network 1 phase at 3kW power MHP Singosaren Wukirsari Imogiri Bantul Yogyakarta while impaired network efficiently and effectively so that security of electricity generation and distribution to be reliable as well as consumers gain the convenience of electricity. Results obtained data that includes dimensions of the channel width of 0,62 m 0,32 m height of the water discharge 0,1389 m3/second with 60% efficiency, resulting of output power in 261 watts. Water mill (waterwheel) used with the number of blades 20 pieces, outer diameter 2,1 m, diameter of 0,68 m, width 0,62 m category undershot waterwheel. While zero load, transmission using Hijet car axle with 14,3 rpm and 1.948 rpm to generator, whereas at normal load 250 watt windmill rotation 10,6 rpm and generator 1.421 rpm. Meter reading analog, digital and microcontroller has R2 = 0,953 means reading the voltage value of 3 is not much different measuring instruments. Statistical test non parametric test level matched (Wilcoxon's Signed Rank Test) with n = 20, alpha = 0,05, the measurement results the LCD microcontroller with theoretical study obtained Tcount = 45 and Ttable = 52, measurement of LCD microcontroller with gauge analog, Tcount = 28, Ttable = 52 and measurement LCD microcontroller with a digital gauge and Tcount = 39, Ttable = 52, Tcount <Ttable , it can be concluded that there was no difference in reading the instruments. Recloser response to disturbances that occurred from the first disturbance to three each time a distance of less than 10 seconds, the recloser will calculate the number of failures (fault), if the same until the third time the microcontroller will give signal to the magnetic contactor to turn off the circuit remains broken (permanent OFF). However, if the time of short circuit between the first and third time over 10 seconds then the recloser does not govern the microcontroller to remain OFF.
first_indexed 2024-03-13T22:09:17Z
format Thesis
id oai:generic.eprints.org:90079
institution Universiti Gadjah Mada
last_indexed 2024-03-13T22:09:17Z
publishDate 2011
publisher [Yogyakarta] : Universitas Gadjah Mada
record_format dspace
spelling oai:generic.eprints.org:900792014-08-20T02:51:54Z https://repository.ugm.ac.id/90079/ OPTIMALISASI DAN RANCANGAN SISTEM PROTEKSI PENUTUP BALIK OTOMATIS (RECLOSER) JARINGAN DISTRIBUSI LISTRIK 1 FASE DAYA 3KW PADA PLTMh SINGOSAREN WUKIRSARI IMOGIRI BANTUL YOGYAKARTA (Berbasis Mikrokontroler ATmega16) , IMAM SYAFI'I , Prof.(Emr). Adhi Susanto, M.Sc., Ph.D. ETD MHP began many built in several areas but to obtain security comfort electrically to the load-more (overload) or other disorders that are still desperately needed extreme protective equipment that can prevent damage to the generator so that the continuity of electricity distribution services is well maintained and reliable. The purpose of this research is to design and construct a protection device (recloser) (Safety equipment impaired overload is automatically opened and closed electrical circuit) programmed with ATmega16 microcontroller in electricity distribution network 1 phase at 3kW power MHP Singosaren Wukirsari Imogiri Bantul Yogyakarta while impaired network efficiently and effectively so that security of electricity generation and distribution to be reliable as well as consumers gain the convenience of electricity. Results obtained data that includes dimensions of the channel width of 0,62 m 0,32 m height of the water discharge 0,1389 m3/second with 60% efficiency, resulting of output power in 261 watts. Water mill (waterwheel) used with the number of blades 20 pieces, outer diameter 2,1 m, diameter of 0,68 m, width 0,62 m category undershot waterwheel. While zero load, transmission using Hijet car axle with 14,3 rpm and 1.948 rpm to generator, whereas at normal load 250 watt windmill rotation 10,6 rpm and generator 1.421 rpm. Meter reading analog, digital and microcontroller has R2 = 0,953 means reading the voltage value of 3 is not much different measuring instruments. Statistical test non parametric test level matched (Wilcoxon's Signed Rank Test) with n = 20, alpha = 0,05, the measurement results the LCD microcontroller with theoretical study obtained Tcount = 45 and Ttable = 52, measurement of LCD microcontroller with gauge analog, Tcount = 28, Ttable = 52 and measurement LCD microcontroller with a digital gauge and Tcount = 39, Ttable = 52, Tcount <Ttable , it can be concluded that there was no difference in reading the instruments. Recloser response to disturbances that occurred from the first disturbance to three each time a distance of less than 10 seconds, the recloser will calculate the number of failures (fault), if the same until the third time the microcontroller will give signal to the magnetic contactor to turn off the circuit remains broken (permanent OFF). However, if the time of short circuit between the first and third time over 10 seconds then the recloser does not govern the microcontroller to remain OFF. [Yogyakarta] : Universitas Gadjah Mada 2011 Thesis NonPeerReviewed , IMAM SYAFI'I and , Prof.(Emr). Adhi Susanto, M.Sc., Ph.D. (2011) OPTIMALISASI DAN RANCANGAN SISTEM PROTEKSI PENUTUP BALIK OTOMATIS (RECLOSER) JARINGAN DISTRIBUSI LISTRIK 1 FASE DAYA 3KW PADA PLTMh SINGOSAREN WUKIRSARI IMOGIRI BANTUL YOGYAKARTA (Berbasis Mikrokontroler ATmega16). UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=52417
spellingShingle ETD
, IMAM SYAFI'I
, Prof.(Emr). Adhi Susanto, M.Sc., Ph.D.
OPTIMALISASI DAN RANCANGAN SISTEM PROTEKSI PENUTUP BALIK OTOMATIS (RECLOSER) JARINGAN DISTRIBUSI LISTRIK 1 FASE DAYA 3KW PADA PLTMh SINGOSAREN WUKIRSARI IMOGIRI BANTUL YOGYAKARTA (Berbasis Mikrokontroler ATmega16)
title OPTIMALISASI DAN RANCANGAN SISTEM PROTEKSI PENUTUP BALIK OTOMATIS (RECLOSER) JARINGAN DISTRIBUSI LISTRIK 1 FASE DAYA 3KW PADA PLTMh SINGOSAREN WUKIRSARI IMOGIRI BANTUL YOGYAKARTA (Berbasis Mikrokontroler ATmega16)
title_full OPTIMALISASI DAN RANCANGAN SISTEM PROTEKSI PENUTUP BALIK OTOMATIS (RECLOSER) JARINGAN DISTRIBUSI LISTRIK 1 FASE DAYA 3KW PADA PLTMh SINGOSAREN WUKIRSARI IMOGIRI BANTUL YOGYAKARTA (Berbasis Mikrokontroler ATmega16)
title_fullStr OPTIMALISASI DAN RANCANGAN SISTEM PROTEKSI PENUTUP BALIK OTOMATIS (RECLOSER) JARINGAN DISTRIBUSI LISTRIK 1 FASE DAYA 3KW PADA PLTMh SINGOSAREN WUKIRSARI IMOGIRI BANTUL YOGYAKARTA (Berbasis Mikrokontroler ATmega16)
title_full_unstemmed OPTIMALISASI DAN RANCANGAN SISTEM PROTEKSI PENUTUP BALIK OTOMATIS (RECLOSER) JARINGAN DISTRIBUSI LISTRIK 1 FASE DAYA 3KW PADA PLTMh SINGOSAREN WUKIRSARI IMOGIRI BANTUL YOGYAKARTA (Berbasis Mikrokontroler ATmega16)
title_short OPTIMALISASI DAN RANCANGAN SISTEM PROTEKSI PENUTUP BALIK OTOMATIS (RECLOSER) JARINGAN DISTRIBUSI LISTRIK 1 FASE DAYA 3KW PADA PLTMh SINGOSAREN WUKIRSARI IMOGIRI BANTUL YOGYAKARTA (Berbasis Mikrokontroler ATmega16)
title_sort optimalisasi dan rancangan sistem proteksi penutup balik otomatis recloser jaringan distribusi listrik 1 fase daya 3kw pada pltmh singosaren wukirsari imogiri bantul yogyakarta berbasis mikrokontroler atmega16
topic ETD
work_keys_str_mv AT imamsyafii optimalisasidanrancangansistemproteksipenutupbalikotomatisrecloserjaringandistribusilistrik1fasedaya3kwpadapltmhsingosarenwukirsariimogiribantulyogyakartaberbasismikrokontroleratmega16
AT profemradhisusantomscphd optimalisasidanrancangansistemproteksipenutupbalikotomatisrecloserjaringandistribusilistrik1fasedaya3kwpadapltmhsingosarenwukirsariimogiribantulyogyakartaberbasismikrokontroleratmega16