PERANCANGAN SPIROMETER MENGGUNAKAN SENSOR TEKANAN MPX2010DP

Spirometer is needed in the medical world but not all hospitals have facilities spirometer. The high price of a spirometer is one of the factors why the unavailability of a spirometer at each hospital or clinic. To solve the problem then be made a low-cost spirometer with a simpler device. Spiromete...

Full description

Bibliographic Details
Main Authors: , Laura Anastasi Seseragi Lapono, , Dr. Agus Harjoko
Format: Thesis
Published: [Yogyakarta] : Universitas Gadjah Mada 2011
Subjects:
ETD
_version_ 1826043802599555072
author , Laura Anastasi Seseragi Lapono
, Dr. Agus Harjoko
author_facet , Laura Anastasi Seseragi Lapono
, Dr. Agus Harjoko
author_sort , Laura Anastasi Seseragi Lapono
collection UGM
description Spirometer is needed in the medical world but not all hospitals have facilities spirometer. The high price of a spirometer is one of the factors why the unavailability of a spirometer at each hospital or clinic. To solve the problem then be made a low-cost spirometer with a simpler device. Spirometer which was made in this project is the flow spirometer that uses a method of measuring differential pressure, design of mouthpiece uses a model of orifice, and it can measure Forced Expiratory Volume in First Second (FEV1) and Forced Vital Capacity (FVC). Data acquisition system consists of pressure sensors MPX2010DP, differential amplifier, a microcontroller ATmega8535, and a computer to display the measurement results. Spirometer was tested to a man 27 years with height 167 cm and a woman 28 years with height 163 cm. According to the predictive value of Pneumobile Project Indonesia, for men to have FEV1 predictive value is 2,838 L and FVC predictive value is 3,835 L. While the value of FEV1 of the measurement results is 2,434 L and FVC values is 3,452 L. For women to have FEV1 predictive value is 2,625 L and FVC predictive value is 2,988 L. While the value of FEV1 of the measurement results is 2,230 L and FVC values is 2,603 L. Interpretation of spirometer results for both samples have a normal condition.
first_indexed 2024-03-13T22:09:31Z
format Thesis
id oai:generic.eprints.org:90151
institution Universiti Gadjah Mada
last_indexed 2024-03-13T22:09:31Z
publishDate 2011
publisher [Yogyakarta] : Universitas Gadjah Mada
record_format dspace
spelling oai:generic.eprints.org:901512014-08-20T02:52:23Z https://repository.ugm.ac.id/90151/ PERANCANGAN SPIROMETER MENGGUNAKAN SENSOR TEKANAN MPX2010DP , Laura Anastasi Seseragi Lapono , Dr. Agus Harjoko ETD Spirometer is needed in the medical world but not all hospitals have facilities spirometer. The high price of a spirometer is one of the factors why the unavailability of a spirometer at each hospital or clinic. To solve the problem then be made a low-cost spirometer with a simpler device. Spirometer which was made in this project is the flow spirometer that uses a method of measuring differential pressure, design of mouthpiece uses a model of orifice, and it can measure Forced Expiratory Volume in First Second (FEV1) and Forced Vital Capacity (FVC). Data acquisition system consists of pressure sensors MPX2010DP, differential amplifier, a microcontroller ATmega8535, and a computer to display the measurement results. Spirometer was tested to a man 27 years with height 167 cm and a woman 28 years with height 163 cm. According to the predictive value of Pneumobile Project Indonesia, for men to have FEV1 predictive value is 2,838 L and FVC predictive value is 3,835 L. While the value of FEV1 of the measurement results is 2,434 L and FVC values is 3,452 L. For women to have FEV1 predictive value is 2,625 L and FVC predictive value is 2,988 L. While the value of FEV1 of the measurement results is 2,230 L and FVC values is 2,603 L. Interpretation of spirometer results for both samples have a normal condition. [Yogyakarta] : Universitas Gadjah Mada 2011 Thesis NonPeerReviewed , Laura Anastasi Seseragi Lapono and , Dr. Agus Harjoko (2011) PERANCANGAN SPIROMETER MENGGUNAKAN SENSOR TEKANAN MPX2010DP. UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=52570
spellingShingle ETD
, Laura Anastasi Seseragi Lapono
, Dr. Agus Harjoko
PERANCANGAN SPIROMETER MENGGUNAKAN SENSOR TEKANAN MPX2010DP
title PERANCANGAN SPIROMETER MENGGUNAKAN SENSOR TEKANAN MPX2010DP
title_full PERANCANGAN SPIROMETER MENGGUNAKAN SENSOR TEKANAN MPX2010DP
title_fullStr PERANCANGAN SPIROMETER MENGGUNAKAN SENSOR TEKANAN MPX2010DP
title_full_unstemmed PERANCANGAN SPIROMETER MENGGUNAKAN SENSOR TEKANAN MPX2010DP
title_short PERANCANGAN SPIROMETER MENGGUNAKAN SENSOR TEKANAN MPX2010DP
title_sort perancangan spirometer menggunakan sensor tekanan mpx2010dp
topic ETD
work_keys_str_mv AT lauraanastasiseseragilapono perancanganspirometermenggunakansensortekananmpx2010dp
AT dragusharjoko perancanganspirometermenggunakansensortekananmpx2010dp