PERANCANGAN SPIROMETER MENGGUNAKAN SENSOR TEKANAN MPX2010DP
Spirometer is needed in the medical world but not all hospitals have facilities spirometer. The high price of a spirometer is one of the factors why the unavailability of a spirometer at each hospital or clinic. To solve the problem then be made a low-cost spirometer with a simpler device. Spiromete...
Main Authors: | , |
---|---|
Format: | Thesis |
Published: |
[Yogyakarta] : Universitas Gadjah Mada
2011
|
Subjects: |
_version_ | 1826043802599555072 |
---|---|
author | , Laura Anastasi Seseragi Lapono , Dr. Agus Harjoko |
author_facet | , Laura Anastasi Seseragi Lapono , Dr. Agus Harjoko |
author_sort | , Laura Anastasi Seseragi Lapono |
collection | UGM |
description | Spirometer is needed in the medical world but not all hospitals have
facilities spirometer. The high price of a spirometer is one of the factors why the
unavailability of a spirometer at each hospital or clinic. To solve the problem then
be made a low-cost spirometer with a simpler device. Spirometer which was made
in this project is the flow spirometer that uses a method of measuring differential
pressure, design of mouthpiece uses a model of orifice, and it can measure Forced
Expiratory Volume in First Second (FEV1) and Forced Vital Capacity (FVC).
Data acquisition system consists of pressure sensors MPX2010DP, differential
amplifier, a microcontroller ATmega8535, and a computer to display the
measurement results.
Spirometer was tested to a man 27 years with height 167 cm and a woman
28 years with height 163 cm. According to the predictive value of Pneumobile
Project Indonesia, for men to have FEV1 predictive value is 2,838 L and FVC
predictive value is 3,835 L. While the value of FEV1 of the measurement results is
2,434 L and FVC values is 3,452 L. For women to have FEV1 predictive value is
2,625 L and FVC predictive value is 2,988 L. While the value of FEV1 of the
measurement results is 2,230 L and FVC values is 2,603 L. Interpretation of
spirometer results for both samples have a normal condition. |
first_indexed | 2024-03-13T22:09:31Z |
format | Thesis |
id | oai:generic.eprints.org:90151 |
institution | Universiti Gadjah Mada |
last_indexed | 2024-03-13T22:09:31Z |
publishDate | 2011 |
publisher | [Yogyakarta] : Universitas Gadjah Mada |
record_format | dspace |
spelling | oai:generic.eprints.org:901512014-08-20T02:52:23Z https://repository.ugm.ac.id/90151/ PERANCANGAN SPIROMETER MENGGUNAKAN SENSOR TEKANAN MPX2010DP , Laura Anastasi Seseragi Lapono , Dr. Agus Harjoko ETD Spirometer is needed in the medical world but not all hospitals have facilities spirometer. The high price of a spirometer is one of the factors why the unavailability of a spirometer at each hospital or clinic. To solve the problem then be made a low-cost spirometer with a simpler device. Spirometer which was made in this project is the flow spirometer that uses a method of measuring differential pressure, design of mouthpiece uses a model of orifice, and it can measure Forced Expiratory Volume in First Second (FEV1) and Forced Vital Capacity (FVC). Data acquisition system consists of pressure sensors MPX2010DP, differential amplifier, a microcontroller ATmega8535, and a computer to display the measurement results. Spirometer was tested to a man 27 years with height 167 cm and a woman 28 years with height 163 cm. According to the predictive value of Pneumobile Project Indonesia, for men to have FEV1 predictive value is 2,838 L and FVC predictive value is 3,835 L. While the value of FEV1 of the measurement results is 2,434 L and FVC values is 3,452 L. For women to have FEV1 predictive value is 2,625 L and FVC predictive value is 2,988 L. While the value of FEV1 of the measurement results is 2,230 L and FVC values is 2,603 L. Interpretation of spirometer results for both samples have a normal condition. [Yogyakarta] : Universitas Gadjah Mada 2011 Thesis NonPeerReviewed , Laura Anastasi Seseragi Lapono and , Dr. Agus Harjoko (2011) PERANCANGAN SPIROMETER MENGGUNAKAN SENSOR TEKANAN MPX2010DP. UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=52570 |
spellingShingle | ETD , Laura Anastasi Seseragi Lapono , Dr. Agus Harjoko PERANCANGAN SPIROMETER MENGGUNAKAN SENSOR TEKANAN MPX2010DP |
title | PERANCANGAN SPIROMETER MENGGUNAKAN
SENSOR TEKANAN MPX2010DP |
title_full | PERANCANGAN SPIROMETER MENGGUNAKAN
SENSOR TEKANAN MPX2010DP |
title_fullStr | PERANCANGAN SPIROMETER MENGGUNAKAN
SENSOR TEKANAN MPX2010DP |
title_full_unstemmed | PERANCANGAN SPIROMETER MENGGUNAKAN
SENSOR TEKANAN MPX2010DP |
title_short | PERANCANGAN SPIROMETER MENGGUNAKAN
SENSOR TEKANAN MPX2010DP |
title_sort | perancangan spirometer menggunakan sensor tekanan mpx2010dp |
topic | ETD |
work_keys_str_mv | AT lauraanastasiseseragilapono perancanganspirometermenggunakansensortekananmpx2010dp AT dragusharjoko perancanganspirometermenggunakansensortekananmpx2010dp |