EFEKTIFITAS PENGGUNAAN KABEL BAJA DAN KOMPOSIT MORTAR SEBAGAI PERKUATAN MOMEN NEGATIF BALOK BETON BERTULANG TAMPANG T DENGAN PENAMBAHAN TULANGAN KONVENSIONAL PADA BLOK TEKAN

Reinforcement is a solution in increasing the supporting force of a reinforced concrete structure as well as to lengthen its service life. The objective of this study is to identify the increase of flexural capacity, stiffness, ductility and cracking pattern in the beam negative moment area. Three s...

Full description

Bibliographic Details
Main Authors: , dimas langga chandra galuh, , Prof. Ir. Iman Satyarno, ME, Ph.D
Format: Thesis
Published: [Yogyakarta] : Universitas Gadjah Mada 2012
Subjects:
ETD
_version_ 1797032158757388288
author , dimas langga chandra galuh
, Prof. Ir. Iman Satyarno, ME, Ph.D,
author_facet , dimas langga chandra galuh
, Prof. Ir. Iman Satyarno, ME, Ph.D,
author_sort , dimas langga chandra galuh
collection UGM
description Reinforcement is a solution in increasing the supporting force of a reinforced concrete structure as well as to lengthen its service life. The objective of this study is to identify the increase of flexural capacity, stiffness, ductility and cracking pattern in the beam negative moment area. Three specimens were made that consisted of one controlling beam (BK), one beam reinforced by 4�10 mm steel wire in the tensile area (BP1) and one beam reinforced by 4�10 mm steel wire in the tensile area and 2P8 mm in the compressive area (BP2) with mortar as the concrete blanket. Other specimen was T-sectional reinforced concrete beam in (l) 2400 mm length, (h) 250 mm height, (bw) 150 mm width, with flens width and height in (bf) 400 mm and (t) 75 mm, respectively. The diameters of wire rope and reinforcing steel used for the reinforcement were 10 mm and 8 mm, respectively. Beam was tested for its pure flexure by static loading and simple pedestal. Along the test, measurements on the loading, strain and deflection were taken. The test results were then compared to the layers method, SNI and Response-2000 program. Results of the test showed that the maximum loading for BK, BP1, and BP2 specimens were 88.5 kN, 180 kN, and 259 kN, respectively. Comparative ratios of flexural capacity of BP1 and BP2 to (BK) were 2.03 and 2.93. The comparative flexural capacity to Response-2000 program for BK, BP1, and BP2 specimens were 1.05, 0.88, and 0.89, respectively. The comparative flexural capacity by layers1 method (ignoring the wing reinforcement) for BK, BP1, and BP2 specimens were 1.28, 0.76, and 0.78. The comparative flexural capacity by layers2 method (considering the wing reinforcement) for BK, BP1, and BP2 specimens were 1.28, 0.79, and 0.80, respectively. Comparative flexural capacities by SNI method for BK, BP1, and BP2 specimens were 1.05, 1.13, and 1.02, respectively. Comparative initial stiffness ratios of BP1 and BP2 to BK were 1.1 and 1.6. The comparative secant stiffness ratios of BP1 and BP2 to BK were 0.86 and 1.6. The comparative ratios of ductility factor of BP1 and BP2 to BK were 0.68 and 1.4. The collapsing pattern of each reinforcing beam was debonding, but on the reinforcing beam, it still gave the tensile stress that loading was increased to the maximum.
first_indexed 2024-03-13T22:34:12Z
format Thesis
id oai:generic.eprints.org:97887
institution Universiti Gadjah Mada
last_indexed 2024-03-13T22:34:12Z
publishDate 2012
publisher [Yogyakarta] : Universitas Gadjah Mada
record_format dspace
spelling oai:generic.eprints.org:978872016-03-04T08:49:40Z https://repository.ugm.ac.id/97887/ EFEKTIFITAS PENGGUNAAN KABEL BAJA DAN KOMPOSIT MORTAR SEBAGAI PERKUATAN MOMEN NEGATIF BALOK BETON BERTULANG TAMPANG T DENGAN PENAMBAHAN TULANGAN KONVENSIONAL PADA BLOK TEKAN , dimas langga chandra galuh , Prof. Ir. Iman Satyarno, ME, Ph.D, ETD Reinforcement is a solution in increasing the supporting force of a reinforced concrete structure as well as to lengthen its service life. The objective of this study is to identify the increase of flexural capacity, stiffness, ductility and cracking pattern in the beam negative moment area. Three specimens were made that consisted of one controlling beam (BK), one beam reinforced by 4�10 mm steel wire in the tensile area (BP1) and one beam reinforced by 4�10 mm steel wire in the tensile area and 2P8 mm in the compressive area (BP2) with mortar as the concrete blanket. Other specimen was T-sectional reinforced concrete beam in (l) 2400 mm length, (h) 250 mm height, (bw) 150 mm width, with flens width and height in (bf) 400 mm and (t) 75 mm, respectively. The diameters of wire rope and reinforcing steel used for the reinforcement were 10 mm and 8 mm, respectively. Beam was tested for its pure flexure by static loading and simple pedestal. Along the test, measurements on the loading, strain and deflection were taken. The test results were then compared to the layers method, SNI and Response-2000 program. Results of the test showed that the maximum loading for BK, BP1, and BP2 specimens were 88.5 kN, 180 kN, and 259 kN, respectively. Comparative ratios of flexural capacity of BP1 and BP2 to (BK) were 2.03 and 2.93. The comparative flexural capacity to Response-2000 program for BK, BP1, and BP2 specimens were 1.05, 0.88, and 0.89, respectively. The comparative flexural capacity by layers1 method (ignoring the wing reinforcement) for BK, BP1, and BP2 specimens were 1.28, 0.76, and 0.78. The comparative flexural capacity by layers2 method (considering the wing reinforcement) for BK, BP1, and BP2 specimens were 1.28, 0.79, and 0.80, respectively. Comparative flexural capacities by SNI method for BK, BP1, and BP2 specimens were 1.05, 1.13, and 1.02, respectively. Comparative initial stiffness ratios of BP1 and BP2 to BK were 1.1 and 1.6. The comparative secant stiffness ratios of BP1 and BP2 to BK were 0.86 and 1.6. The comparative ratios of ductility factor of BP1 and BP2 to BK were 0.68 and 1.4. The collapsing pattern of each reinforcing beam was debonding, but on the reinforcing beam, it still gave the tensile stress that loading was increased to the maximum. [Yogyakarta] : Universitas Gadjah Mada 2012 Thesis NonPeerReviewed , dimas langga chandra galuh and , Prof. Ir. Iman Satyarno, ME, Ph.D, (2012) EFEKTIFITAS PENGGUNAAN KABEL BAJA DAN KOMPOSIT MORTAR SEBAGAI PERKUATAN MOMEN NEGATIF BALOK BETON BERTULANG TAMPANG T DENGAN PENAMBAHAN TULANGAN KONVENSIONAL PADA BLOK TEKAN. UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=54024
spellingShingle ETD
, dimas langga chandra galuh
, Prof. Ir. Iman Satyarno, ME, Ph.D,
EFEKTIFITAS PENGGUNAAN KABEL BAJA DAN KOMPOSIT MORTAR SEBAGAI PERKUATAN MOMEN NEGATIF BALOK BETON BERTULANG TAMPANG T DENGAN PENAMBAHAN TULANGAN KONVENSIONAL PADA BLOK TEKAN
title EFEKTIFITAS PENGGUNAAN KABEL BAJA DAN KOMPOSIT MORTAR SEBAGAI PERKUATAN MOMEN NEGATIF BALOK BETON BERTULANG TAMPANG T DENGAN PENAMBAHAN TULANGAN KONVENSIONAL PADA BLOK TEKAN
title_full EFEKTIFITAS PENGGUNAAN KABEL BAJA DAN KOMPOSIT MORTAR SEBAGAI PERKUATAN MOMEN NEGATIF BALOK BETON BERTULANG TAMPANG T DENGAN PENAMBAHAN TULANGAN KONVENSIONAL PADA BLOK TEKAN
title_fullStr EFEKTIFITAS PENGGUNAAN KABEL BAJA DAN KOMPOSIT MORTAR SEBAGAI PERKUATAN MOMEN NEGATIF BALOK BETON BERTULANG TAMPANG T DENGAN PENAMBAHAN TULANGAN KONVENSIONAL PADA BLOK TEKAN
title_full_unstemmed EFEKTIFITAS PENGGUNAAN KABEL BAJA DAN KOMPOSIT MORTAR SEBAGAI PERKUATAN MOMEN NEGATIF BALOK BETON BERTULANG TAMPANG T DENGAN PENAMBAHAN TULANGAN KONVENSIONAL PADA BLOK TEKAN
title_short EFEKTIFITAS PENGGUNAAN KABEL BAJA DAN KOMPOSIT MORTAR SEBAGAI PERKUATAN MOMEN NEGATIF BALOK BETON BERTULANG TAMPANG T DENGAN PENAMBAHAN TULANGAN KONVENSIONAL PADA BLOK TEKAN
title_sort efektifitas penggunaan kabel baja dan komposit mortar sebagai perkuatan momen negatif balok beton bertulang tampang t dengan penambahan tulangan konvensional pada blok tekan
topic ETD
work_keys_str_mv AT dimaslanggachandragaluh efektifitaspenggunaankabelbajadankompositmortarsebagaiperkuatanmomennegatifbalokbetonbertulangtampangtdenganpenambahantulangankonvensionalpadabloktekan
AT profirimansatyarnomephd efektifitaspenggunaankabelbajadankompositmortarsebagaiperkuatanmomennegatifbalokbetonbertulangtampangtdenganpenambahantulangankonvensionalpadabloktekan