STUDI EKSPERIMENTAL PENGARUH DIMENSI NOSEL TERHADAP KINERJA LIQUID JET GAS PUMP (LJGP)

This study aims to determine the effect of nozzle dimensons on the performance of liquid jet gas pump which functioned as a vacuum pump. Liquid jet gas pump is an energy conversion device that is able to drain the fluid air (secondary flow) by utilizing the water fluid (primary flow/motive flow) by...

Full description

Bibliographic Details
Main Authors: , EDI KARYADI, , Prof. Dr. Ir. Indarto, DEA
Format: Thesis
Published: [Yogyakarta] : Universitas Gadjah Mada 2012
Subjects:
ETD
_version_ 1797032347355316224
author , EDI KARYADI
, Prof. Dr. Ir. Indarto, DEA
author_facet , EDI KARYADI
, Prof. Dr. Ir. Indarto, DEA
author_sort , EDI KARYADI
collection UGM
description This study aims to determine the effect of nozzle dimensons on the performance of liquid jet gas pump which functioned as a vacuum pump. Liquid jet gas pump is an energy conversion device that is able to drain the fluid air (secondary flow) by utilizing the water fluid (primary flow/motive flow) by ulitilizing the water fluid (primary flow/motive flow) based on the pressure different between the two fluids without using moving parts. The term of dimensions of the nozzle is the diameter of the nozzle on the outlet stream of the motive. The study was conducted using experimental method with the parameters studied are the relationship between the dimensions of the nozzle efficiency, flow ratio, and coefficient of the nozzle. The type of nozzle used is straight-hole nozzle with a diameter of 8, 9, 10, 11, and 12 mm. While the primary flow ranged from 0.44 to 1.44 L/s and secondary flow ranged from 0.04 to 0.42 L/s. The results showed a significant relationship between change in the dimensions of the nozzle to the efficiency and the coefficient of the nozzle, which with increasing diameter of the nozzle tends to result in decreased efficiency and coefficient of the nozzle. The resulting maximum efficiency of each nozzle with a nozzle diameter of 8, 9, 10 ,11, and 12 mm respectively were 20.21, 16.77, 6.58, 12.25, and 6.99 %. While the coefficient of the nozzle row is 0.88, 0.76, 0.61, 0.76, and 0.76.
first_indexed 2024-03-13T22:36:59Z
format Thesis
id oai:generic.eprints.org:98749
institution Universiti Gadjah Mada
last_indexed 2024-03-13T22:36:59Z
publishDate 2012
publisher [Yogyakarta] : Universitas Gadjah Mada
record_format dspace
spelling oai:generic.eprints.org:987492016-03-04T08:46:22Z https://repository.ugm.ac.id/98749/ STUDI EKSPERIMENTAL PENGARUH DIMENSI NOSEL TERHADAP KINERJA LIQUID JET GAS PUMP (LJGP) , EDI KARYADI , Prof. Dr. Ir. Indarto, DEA ETD This study aims to determine the effect of nozzle dimensons on the performance of liquid jet gas pump which functioned as a vacuum pump. Liquid jet gas pump is an energy conversion device that is able to drain the fluid air (secondary flow) by utilizing the water fluid (primary flow/motive flow) by ulitilizing the water fluid (primary flow/motive flow) based on the pressure different between the two fluids without using moving parts. The term of dimensions of the nozzle is the diameter of the nozzle on the outlet stream of the motive. The study was conducted using experimental method with the parameters studied are the relationship between the dimensions of the nozzle efficiency, flow ratio, and coefficient of the nozzle. The type of nozzle used is straight-hole nozzle with a diameter of 8, 9, 10, 11, and 12 mm. While the primary flow ranged from 0.44 to 1.44 L/s and secondary flow ranged from 0.04 to 0.42 L/s. The results showed a significant relationship between change in the dimensions of the nozzle to the efficiency and the coefficient of the nozzle, which with increasing diameter of the nozzle tends to result in decreased efficiency and coefficient of the nozzle. The resulting maximum efficiency of each nozzle with a nozzle diameter of 8, 9, 10 ,11, and 12 mm respectively were 20.21, 16.77, 6.58, 12.25, and 6.99 %. While the coefficient of the nozzle row is 0.88, 0.76, 0.61, 0.76, and 0.76. [Yogyakarta] : Universitas Gadjah Mada 2012 Thesis NonPeerReviewed , EDI KARYADI and , Prof. Dr. Ir. Indarto, DEA (2012) STUDI EKSPERIMENTAL PENGARUH DIMENSI NOSEL TERHADAP KINERJA LIQUID JET GAS PUMP (LJGP). UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=54618
spellingShingle ETD
, EDI KARYADI
, Prof. Dr. Ir. Indarto, DEA
STUDI EKSPERIMENTAL PENGARUH DIMENSI NOSEL TERHADAP KINERJA LIQUID JET GAS PUMP (LJGP)
title STUDI EKSPERIMENTAL PENGARUH DIMENSI NOSEL TERHADAP KINERJA LIQUID JET GAS PUMP (LJGP)
title_full STUDI EKSPERIMENTAL PENGARUH DIMENSI NOSEL TERHADAP KINERJA LIQUID JET GAS PUMP (LJGP)
title_fullStr STUDI EKSPERIMENTAL PENGARUH DIMENSI NOSEL TERHADAP KINERJA LIQUID JET GAS PUMP (LJGP)
title_full_unstemmed STUDI EKSPERIMENTAL PENGARUH DIMENSI NOSEL TERHADAP KINERJA LIQUID JET GAS PUMP (LJGP)
title_short STUDI EKSPERIMENTAL PENGARUH DIMENSI NOSEL TERHADAP KINERJA LIQUID JET GAS PUMP (LJGP)
title_sort studi eksperimental pengaruh dimensi nosel terhadap kinerja liquid jet gas pump ljgp
topic ETD
work_keys_str_mv AT edikaryadi studieksperimentalpengaruhdimensinoselterhadapkinerjaliquidjetgaspumpljgp
AT profdririndartodea studieksperimentalpengaruhdimensinoselterhadapkinerjaliquidjetgaspumpljgp