STUDI EKSPERIMENTAL PENGARUH DIMENSI NOSEL TERHADAP KINERJA LIQUID JET GAS PUMP (LJGP)
This study aims to determine the effect of nozzle dimensons on the performance of liquid jet gas pump which functioned as a vacuum pump. Liquid jet gas pump is an energy conversion device that is able to drain the fluid air (secondary flow) by utilizing the water fluid (primary flow/motive flow) by...
Main Authors: | , |
---|---|
Format: | Thesis |
Published: |
[Yogyakarta] : Universitas Gadjah Mada
2012
|
Subjects: |
_version_ | 1797032347355316224 |
---|---|
author | , EDI KARYADI , Prof. Dr. Ir. Indarto, DEA |
author_facet | , EDI KARYADI , Prof. Dr. Ir. Indarto, DEA |
author_sort | , EDI KARYADI |
collection | UGM |
description | This study aims to determine the effect of nozzle dimensons on the
performance of liquid jet gas pump which functioned as a vacuum pump. Liquid
jet gas pump is an energy conversion device that is able to drain the fluid air
(secondary flow) by utilizing the water fluid (primary flow/motive flow) by
ulitilizing the water fluid (primary flow/motive flow) based on the pressure
different between the two fluids without using moving parts.
The term of dimensions of the nozzle is the diameter of the nozzle on the
outlet stream of the motive. The study was conducted using experimental method
with the parameters studied are the relationship between the dimensions of the
nozzle efficiency, flow ratio, and coefficient of the nozzle. The type of nozzle
used is straight-hole nozzle with a diameter of 8, 9, 10, 11, and 12 mm. While the
primary flow ranged from 0.44 to 1.44 L/s and secondary flow ranged from 0.04
to 0.42 L/s.
The results showed a significant relationship between change in the
dimensions of the nozzle to the efficiency and the coefficient of the nozzle, which
with increasing diameter of the nozzle tends to result in decreased efficiency and
coefficient of the nozzle. The resulting maximum efficiency of each nozzle with a
nozzle diameter of 8, 9, 10 ,11, and 12 mm respectively were 20.21, 16.77, 6.58,
12.25, and 6.99 %. While the coefficient of the nozzle row is 0.88, 0.76, 0.61,
0.76, and 0.76. |
first_indexed | 2024-03-13T22:36:59Z |
format | Thesis |
id | oai:generic.eprints.org:98749 |
institution | Universiti Gadjah Mada |
last_indexed | 2024-03-13T22:36:59Z |
publishDate | 2012 |
publisher | [Yogyakarta] : Universitas Gadjah Mada |
record_format | dspace |
spelling | oai:generic.eprints.org:987492016-03-04T08:46:22Z https://repository.ugm.ac.id/98749/ STUDI EKSPERIMENTAL PENGARUH DIMENSI NOSEL TERHADAP KINERJA LIQUID JET GAS PUMP (LJGP) , EDI KARYADI , Prof. Dr. Ir. Indarto, DEA ETD This study aims to determine the effect of nozzle dimensons on the performance of liquid jet gas pump which functioned as a vacuum pump. Liquid jet gas pump is an energy conversion device that is able to drain the fluid air (secondary flow) by utilizing the water fluid (primary flow/motive flow) by ulitilizing the water fluid (primary flow/motive flow) based on the pressure different between the two fluids without using moving parts. The term of dimensions of the nozzle is the diameter of the nozzle on the outlet stream of the motive. The study was conducted using experimental method with the parameters studied are the relationship between the dimensions of the nozzle efficiency, flow ratio, and coefficient of the nozzle. The type of nozzle used is straight-hole nozzle with a diameter of 8, 9, 10, 11, and 12 mm. While the primary flow ranged from 0.44 to 1.44 L/s and secondary flow ranged from 0.04 to 0.42 L/s. The results showed a significant relationship between change in the dimensions of the nozzle to the efficiency and the coefficient of the nozzle, which with increasing diameter of the nozzle tends to result in decreased efficiency and coefficient of the nozzle. The resulting maximum efficiency of each nozzle with a nozzle diameter of 8, 9, 10 ,11, and 12 mm respectively were 20.21, 16.77, 6.58, 12.25, and 6.99 %. While the coefficient of the nozzle row is 0.88, 0.76, 0.61, 0.76, and 0.76. [Yogyakarta] : Universitas Gadjah Mada 2012 Thesis NonPeerReviewed , EDI KARYADI and , Prof. Dr. Ir. Indarto, DEA (2012) STUDI EKSPERIMENTAL PENGARUH DIMENSI NOSEL TERHADAP KINERJA LIQUID JET GAS PUMP (LJGP). UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=54618 |
spellingShingle | ETD , EDI KARYADI , Prof. Dr. Ir. Indarto, DEA STUDI EKSPERIMENTAL PENGARUH DIMENSI NOSEL TERHADAP KINERJA LIQUID JET GAS PUMP (LJGP) |
title | STUDI EKSPERIMENTAL PENGARUH DIMENSI NOSEL
TERHADAP KINERJA LIQUID JET GAS PUMP (LJGP) |
title_full | STUDI EKSPERIMENTAL PENGARUH DIMENSI NOSEL
TERHADAP KINERJA LIQUID JET GAS PUMP (LJGP) |
title_fullStr | STUDI EKSPERIMENTAL PENGARUH DIMENSI NOSEL
TERHADAP KINERJA LIQUID JET GAS PUMP (LJGP) |
title_full_unstemmed | STUDI EKSPERIMENTAL PENGARUH DIMENSI NOSEL
TERHADAP KINERJA LIQUID JET GAS PUMP (LJGP) |
title_short | STUDI EKSPERIMENTAL PENGARUH DIMENSI NOSEL
TERHADAP KINERJA LIQUID JET GAS PUMP (LJGP) |
title_sort | studi eksperimental pengaruh dimensi nosel terhadap kinerja liquid jet gas pump ljgp |
topic | ETD |
work_keys_str_mv | AT edikaryadi studieksperimentalpengaruhdimensinoselterhadapkinerjaliquidjetgaspumpljgp AT profdririndartodea studieksperimentalpengaruhdimensinoselterhadapkinerjaliquidjetgaspumpljgp |