STUDI PERBAIKAN FAKTOR DAYA BEBAN INDUKTIF DENGAN KOMPENSATOR REAKTIF SERI MENGGUNAKAN SAKELAR PEMULIH ENERGI MAGNETIK
Nowdays, most of electric loads character in industry is inductive which definetly has low power factor and caused inductive reactance raises. This inductive reactance need to be compansated using apropriate equipments. One of them is the Magnetic Energy Recovery Switch (MERS) which to set capacitor...
Main Authors: | , |
---|---|
Format: | Thesis |
Published: |
[Yogyakarta] : Universitas Gadjah Mada
2012
|
Subjects: |
_version_ | 1797032383758729216 |
---|---|
author | , FAUZAN, ST , Dr. Eng. F. Danang Wijaya, S.T., M.T,. |
author_facet | , FAUZAN, ST , Dr. Eng. F. Danang Wijaya, S.T., M.T,. |
author_sort | , FAUZAN, ST |
collection | UGM |
description | Nowdays, most of electric loads character in industry is inductive which
definetly has low power factor and caused inductive reactance raises. This
inductive reactance need to be compansated using apropriate equipments. One of
them is the Magnetic Energy Recovery Switch (MERS) which to set capacitor
charging and discharging time by controlling firing angle shift of mosfet gate in
MERS circuit. MERS is installed between voltage source and single phase
induction motor as the load so it controls voltage to the load. As an equipment that
gives correction to power factor, MERS also effect terminal voltage on induction
motor that lead to changes in rotation speed of motor. Capacitor reactance is high
when capacitance is low, and MERS reactance is small when firing angle of
mosfet gate is big. When the capacitor reactance is bigger than MERS reactance
then capacitor voltage has discontinue waveform, when they are equal then its
waveform is balance, and when capacitor reactance is smaller than MERS
reactance then its waveform is dc-offset. This study results that MERS is able to
correct power factor up to 0.898 with load voltage 244.6 volts using C = 2.2 µF at
firing angle of 1600 and lead to changes of voltage terminal of inductive load. |
first_indexed | 2024-03-13T22:37:35Z |
format | Thesis |
id | oai:generic.eprints.org:98926 |
institution | Universiti Gadjah Mada |
last_indexed | 2024-03-13T22:37:35Z |
publishDate | 2012 |
publisher | [Yogyakarta] : Universitas Gadjah Mada |
record_format | dspace |
spelling | oai:generic.eprints.org:989262016-03-04T08:46:36Z https://repository.ugm.ac.id/98926/ STUDI PERBAIKAN FAKTOR DAYA BEBAN INDUKTIF DENGAN KOMPENSATOR REAKTIF SERI MENGGUNAKAN SAKELAR PEMULIH ENERGI MAGNETIK , FAUZAN, ST , Dr. Eng. F. Danang Wijaya, S.T., M.T,. ETD Nowdays, most of electric loads character in industry is inductive which definetly has low power factor and caused inductive reactance raises. This inductive reactance need to be compansated using apropriate equipments. One of them is the Magnetic Energy Recovery Switch (MERS) which to set capacitor charging and discharging time by controlling firing angle shift of mosfet gate in MERS circuit. MERS is installed between voltage source and single phase induction motor as the load so it controls voltage to the load. As an equipment that gives correction to power factor, MERS also effect terminal voltage on induction motor that lead to changes in rotation speed of motor. Capacitor reactance is high when capacitance is low, and MERS reactance is small when firing angle of mosfet gate is big. When the capacitor reactance is bigger than MERS reactance then capacitor voltage has discontinue waveform, when they are equal then its waveform is balance, and when capacitor reactance is smaller than MERS reactance then its waveform is dc-offset. This study results that MERS is able to correct power factor up to 0.898 with load voltage 244.6 volts using C = 2.2 µF at firing angle of 1600 and lead to changes of voltage terminal of inductive load. [Yogyakarta] : Universitas Gadjah Mada 2012 Thesis NonPeerReviewed , FAUZAN, ST and , Dr. Eng. F. Danang Wijaya, S.T., M.T,. (2012) STUDI PERBAIKAN FAKTOR DAYA BEBAN INDUKTIF DENGAN KOMPENSATOR REAKTIF SERI MENGGUNAKAN SAKELAR PEMULIH ENERGI MAGNETIK. UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=55421 |
spellingShingle | ETD , FAUZAN, ST , Dr. Eng. F. Danang Wijaya, S.T., M.T,. STUDI PERBAIKAN FAKTOR DAYA BEBAN INDUKTIF DENGAN KOMPENSATOR REAKTIF SERI MENGGUNAKAN SAKELAR PEMULIH ENERGI MAGNETIK |
title | STUDI PERBAIKAN FAKTOR DAYA BEBAN INDUKTIF DENGAN
KOMPENSATOR REAKTIF SERI MENGGUNAKAN
SAKELAR PEMULIH ENERGI MAGNETIK |
title_full | STUDI PERBAIKAN FAKTOR DAYA BEBAN INDUKTIF DENGAN
KOMPENSATOR REAKTIF SERI MENGGUNAKAN
SAKELAR PEMULIH ENERGI MAGNETIK |
title_fullStr | STUDI PERBAIKAN FAKTOR DAYA BEBAN INDUKTIF DENGAN
KOMPENSATOR REAKTIF SERI MENGGUNAKAN
SAKELAR PEMULIH ENERGI MAGNETIK |
title_full_unstemmed | STUDI PERBAIKAN FAKTOR DAYA BEBAN INDUKTIF DENGAN
KOMPENSATOR REAKTIF SERI MENGGUNAKAN
SAKELAR PEMULIH ENERGI MAGNETIK |
title_short | STUDI PERBAIKAN FAKTOR DAYA BEBAN INDUKTIF DENGAN
KOMPENSATOR REAKTIF SERI MENGGUNAKAN
SAKELAR PEMULIH ENERGI MAGNETIK |
title_sort | studi perbaikan faktor daya beban induktif dengan kompensator reaktif seri menggunakan sakelar pemulih energi magnetik |
topic | ETD |
work_keys_str_mv | AT fauzanst studiperbaikanfaktordayabebaninduktifdengankompensatorreaktifserimenggunakansakelarpemulihenergimagnetik AT drengfdanangwijayastmt studiperbaikanfaktordayabebaninduktifdengankompensatorreaktifserimenggunakansakelarpemulihenergimagnetik |