PENGARUH HARMONIK TERHADAP PENURUNAN KAPASITAS DAYA TRAFO DISTRIBUSI 400 kVA DI POLITEKNIK NEGERI SEMARANG

The Semarang State Polytechnic as an institution of higher vocational education currently has more than 500 units computers which is spread out on 21 computer laboratories / multimedia laboratories. In each laboratory is equipped with air conditioner (AC). Power supply system in Polines is served by...

Full description

Bibliographic Details
Main Authors: , Akhmad Jamaah, , Dr. Eng. F. Danang Wijaya, S.T., M.T.
Format: Thesis
Published: [Yogyakarta] : Universitas Gadjah Mada 2012
Subjects:
ETD
_version_ 1826045650394939392
author , Akhmad Jamaah
, Dr. Eng. F. Danang Wijaya, S.T., M.T.
author_facet , Akhmad Jamaah
, Dr. Eng. F. Danang Wijaya, S.T., M.T.
author_sort , Akhmad Jamaah
collection UGM
description The Semarang State Polytechnic as an institution of higher vocational education currently has more than 500 units computers which is spread out on 21 computer laboratories / multimedia laboratories. In each laboratory is equipped with air conditioner (AC). Power supply system in Polines is served by 2 transformers, named transformer transformer III and transformer I . The power capacity of transformer III and transformer I are 400 kVA . Computer, printer, energy-efficient lighting and other appliances with motor speed control are a non-linear loads that cause harmonics in the power system network. High content of harmonics on power system network causes overheating to the distribution transformers. It is not treated immediately will cause the transformer life time becomes shorter. The research was aimed to determine harmonics content and its effect on distribution transformers in Polines by performing measurements on transformers under load conditions. The transformers load was in accordance with the required of Polines load in academic and administrativ activities. The comparation method between the results of measurements with the IEEE 519-1992 standard is used to analyze the problem. By comparing the measurement results with the IEEE 519-1992 standard, it can be determined whether the tranformer need to be derating or not. Based on the results of the research, the harmonic content of the transformer III and transformer I for the total harmonic content of voltage (THDV) was below the standard (<5%) and total harmonic current content (TDD) or IHD for the second transformer was also below the standard. So that the transformers did not need for derating. However, due to the fact that transformer was over heated, it means that the heat of the transformer has gone beyond that allowed by the standard heat SPLN 8-2: 1991, then it needs to be calculated transformer losses increase due to load containing harmonics. The results of the research indicate that, the harmonic content transformer III for the TDD and IHD were higher than the transformer I, this causes higher heating effect. The highest temperature for transformer III was 67.5 °C, while the transformer I was 66.2 oC.
first_indexed 2024-03-13T22:40:22Z
format Thesis
id oai:generic.eprints.org:99837
institution Universiti Gadjah Mada
last_indexed 2024-03-13T22:40:22Z
publishDate 2012
publisher [Yogyakarta] : Universitas Gadjah Mada
record_format dspace
spelling oai:generic.eprints.org:998372016-03-04T08:45:33Z https://repository.ugm.ac.id/99837/ PENGARUH HARMONIK TERHADAP PENURUNAN KAPASITAS DAYA TRAFO DISTRIBUSI 400 kVA DI POLITEKNIK NEGERI SEMARANG , Akhmad Jamaah , Dr. Eng. F. Danang Wijaya, S.T., M.T. ETD The Semarang State Polytechnic as an institution of higher vocational education currently has more than 500 units computers which is spread out on 21 computer laboratories / multimedia laboratories. In each laboratory is equipped with air conditioner (AC). Power supply system in Polines is served by 2 transformers, named transformer transformer III and transformer I . The power capacity of transformer III and transformer I are 400 kVA . Computer, printer, energy-efficient lighting and other appliances with motor speed control are a non-linear loads that cause harmonics in the power system network. High content of harmonics on power system network causes overheating to the distribution transformers. It is not treated immediately will cause the transformer life time becomes shorter. The research was aimed to determine harmonics content and its effect on distribution transformers in Polines by performing measurements on transformers under load conditions. The transformers load was in accordance with the required of Polines load in academic and administrativ activities. The comparation method between the results of measurements with the IEEE 519-1992 standard is used to analyze the problem. By comparing the measurement results with the IEEE 519-1992 standard, it can be determined whether the tranformer need to be derating or not. Based on the results of the research, the harmonic content of the transformer III and transformer I for the total harmonic content of voltage (THDV) was below the standard (<5%) and total harmonic current content (TDD) or IHD for the second transformer was also below the standard. So that the transformers did not need for derating. However, due to the fact that transformer was over heated, it means that the heat of the transformer has gone beyond that allowed by the standard heat SPLN 8-2: 1991, then it needs to be calculated transformer losses increase due to load containing harmonics. The results of the research indicate that, the harmonic content transformer III for the TDD and IHD were higher than the transformer I, this causes higher heating effect. The highest temperature for transformer III was 67.5 °C, while the transformer I was 66.2 oC. [Yogyakarta] : Universitas Gadjah Mada 2012 Thesis NonPeerReviewed , Akhmad Jamaah and , Dr. Eng. F. Danang Wijaya, S.T., M.T. (2012) PENGARUH HARMONIK TERHADAP PENURUNAN KAPASITAS DAYA TRAFO DISTRIBUSI 400 kVA DI POLITEKNIK NEGERI SEMARANG. UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=56046
spellingShingle ETD
, Akhmad Jamaah
, Dr. Eng. F. Danang Wijaya, S.T., M.T.
PENGARUH HARMONIK TERHADAP PENURUNAN KAPASITAS DAYA TRAFO DISTRIBUSI 400 kVA DI POLITEKNIK NEGERI SEMARANG
title PENGARUH HARMONIK TERHADAP PENURUNAN KAPASITAS DAYA TRAFO DISTRIBUSI 400 kVA DI POLITEKNIK NEGERI SEMARANG
title_full PENGARUH HARMONIK TERHADAP PENURUNAN KAPASITAS DAYA TRAFO DISTRIBUSI 400 kVA DI POLITEKNIK NEGERI SEMARANG
title_fullStr PENGARUH HARMONIK TERHADAP PENURUNAN KAPASITAS DAYA TRAFO DISTRIBUSI 400 kVA DI POLITEKNIK NEGERI SEMARANG
title_full_unstemmed PENGARUH HARMONIK TERHADAP PENURUNAN KAPASITAS DAYA TRAFO DISTRIBUSI 400 kVA DI POLITEKNIK NEGERI SEMARANG
title_short PENGARUH HARMONIK TERHADAP PENURUNAN KAPASITAS DAYA TRAFO DISTRIBUSI 400 kVA DI POLITEKNIK NEGERI SEMARANG
title_sort pengaruh harmonik terhadap penurunan kapasitas daya trafo distribusi 400 kva di politeknik negeri semarang
topic ETD
work_keys_str_mv AT akhmadjamaah pengaruhharmonikterhadappenurunankapasitasdayatrafodistribusi400kvadipolitekniknegerisemarang
AT drengfdanangwijayastmt pengaruhharmonikterhadappenurunankapasitasdayatrafodistribusi400kvadipolitekniknegerisemarang