PSSDB load bearing wall with window opening - effect of butt joint in dryboard / Prof Madya Ir. Siti Hawa Hamzah …[et al.]

Profiled steel sheet dry board or PSSDB system is a new innovative composite construction system with a potential to be expanded in application as an alternative to flooring, wall unit and roofing system. In this study, load-bearing walls with window opening were constructed using PSSDB. The investi...

Full description

Bibliographic Details
Main Authors: Hamzah, Siti Hawa (Prof. Madya Ir.), Yong, Chua Bon, Saari @Ash'ari, Nadiah, Marwi, Mat Som
Format: Research Reports
Language:English
Published: 2003
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/32400/1/32400.pdf
_version_ 1825737563750531072
author Hamzah, Siti Hawa (Prof. Madya Ir.)
Yong, Chua Bon
Saari @Ash'ari, Nadiah
Marwi, Mat Som
author_facet Hamzah, Siti Hawa (Prof. Madya Ir.)
Yong, Chua Bon
Saari @Ash'ari, Nadiah
Marwi, Mat Som
author_sort Hamzah, Siti Hawa (Prof. Madya Ir.)
collection UITM
description Profiled steel sheet dry board or PSSDB system is a new innovative composite construction system with a potential to be expanded in application as an alternative to flooring, wall unit and roofing system. In this study, load-bearing walls with window opening were constructed using PSSDB. The investigation was carried out experimentally to determine the structural behaviour and to see the effect of butt joint in the dry boards. The PSSDB load bearing wall system consists of two dry boards (Cemboards) attached to profiled steel sheet (Bondek II), the core of panel, using mechanical connectors (self-drill screws). Several aspects such as literature review, testing method and analysis of results were included in this research. The samples tested were three (3) numbers of PSSDB walls with window opening and butt joint in the dry boards, and three (3) numbers of PSSDB walls with window opening but without butt joint in the dry boards. The size of each sample is 1000 mm high x 1320 mm wide x 78 mm thick with window opening of size 400 mm x 400 mm x 78 mm. The connectors were fixed at a 100 mm center to center in the longitudinal axis. The samples were subjected to axial compressive load and comparisons were made between the two sets of samples. The average value of the ultimate load capacity for PSSDB load bearing wall with butt joint was* found to be 286 kN, while that for the samples of PSSDB load bearing wall without butt joint was 260 kN. The maximum lateral deflection values for both types of PSSDB walls were 10.7 mm and 13.5 mm respectively. Significant effect of butt joint in dry board were seen in the reduced number of cracks by about 33% in comparison to that without butt joint.
first_indexed 2024-03-06T02:20:07Z
format Research Reports
id oai:ir.uitm.edu.my:32400
institution Universiti Teknologi MARA
language English
last_indexed 2024-03-06T02:20:07Z
publishDate 2003
record_format dspace
spelling oai:ir.uitm.edu.my:324002020-07-15T06:47:17Z https://ir.uitm.edu.my/id/eprint/32400/ PSSDB load bearing wall with window opening - effect of butt joint in dryboard / Prof Madya Ir. Siti Hawa Hamzah …[et al.] Hamzah, Siti Hawa (Prof. Madya Ir.) Yong, Chua Bon Saari @Ash'ari, Nadiah Marwi, Mat Som Machinery exclusive of prime movers Profiled steel sheet dry board or PSSDB system is a new innovative composite construction system with a potential to be expanded in application as an alternative to flooring, wall unit and roofing system. In this study, load-bearing walls with window opening were constructed using PSSDB. The investigation was carried out experimentally to determine the structural behaviour and to see the effect of butt joint in the dry boards. The PSSDB load bearing wall system consists of two dry boards (Cemboards) attached to profiled steel sheet (Bondek II), the core of panel, using mechanical connectors (self-drill screws). Several aspects such as literature review, testing method and analysis of results were included in this research. The samples tested were three (3) numbers of PSSDB walls with window opening and butt joint in the dry boards, and three (3) numbers of PSSDB walls with window opening but without butt joint in the dry boards. The size of each sample is 1000 mm high x 1320 mm wide x 78 mm thick with window opening of size 400 mm x 400 mm x 78 mm. The connectors were fixed at a 100 mm center to center in the longitudinal axis. The samples were subjected to axial compressive load and comparisons were made between the two sets of samples. The average value of the ultimate load capacity for PSSDB load bearing wall with butt joint was* found to be 286 kN, while that for the samples of PSSDB load bearing wall without butt joint was 260 kN. The maximum lateral deflection values for both types of PSSDB walls were 10.7 mm and 13.5 mm respectively. Significant effect of butt joint in dry board were seen in the reduced number of cracks by about 33% in comparison to that without butt joint. 2003-10 Research Reports NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/32400/1/32400.pdf PSSDB load bearing wall with window opening - effect of butt joint in dryboard / Prof Madya Ir. Siti Hawa Hamzah …[et al.]. (2003) [Research Reports] (Unpublished)
spellingShingle Machinery exclusive of prime movers
Hamzah, Siti Hawa (Prof. Madya Ir.)
Yong, Chua Bon
Saari @Ash'ari, Nadiah
Marwi, Mat Som
PSSDB load bearing wall with window opening - effect of butt joint in dryboard / Prof Madya Ir. Siti Hawa Hamzah …[et al.]
title PSSDB load bearing wall with window opening - effect of butt joint in dryboard / Prof Madya Ir. Siti Hawa Hamzah …[et al.]
title_full PSSDB load bearing wall with window opening - effect of butt joint in dryboard / Prof Madya Ir. Siti Hawa Hamzah …[et al.]
title_fullStr PSSDB load bearing wall with window opening - effect of butt joint in dryboard / Prof Madya Ir. Siti Hawa Hamzah …[et al.]
title_full_unstemmed PSSDB load bearing wall with window opening - effect of butt joint in dryboard / Prof Madya Ir. Siti Hawa Hamzah …[et al.]
title_short PSSDB load bearing wall with window opening - effect of butt joint in dryboard / Prof Madya Ir. Siti Hawa Hamzah …[et al.]
title_sort pssdb load bearing wall with window opening effect of butt joint in dryboard prof madya ir siti hawa hamzah et al
topic Machinery exclusive of prime movers
url https://ir.uitm.edu.my/id/eprint/32400/1/32400.pdf
work_keys_str_mv AT hamzahsitihawaprofmadyair pssdbloadbearingwallwithwindowopeningeffectofbuttjointindryboardprofmadyairsitihawahamzahetal
AT yongchuabon pssdbloadbearingwallwithwindowopeningeffectofbuttjointindryboardprofmadyairsitihawahamzahetal
AT saariasharinadiah pssdbloadbearingwallwithwindowopeningeffectofbuttjointindryboardprofmadyairsitihawahamzahetal
AT marwimatsom pssdbloadbearingwallwithwindowopeningeffectofbuttjointindryboardprofmadyairsitihawahamzahetal