Determination of phenol in water sample using high performance liquid chromatography / Nazurah Haron
Phenol as in water is harmful to living organism yet have a toxicity effect for a long-term exposure. In this research, the analysis was achieved on a C18 column coupled with UV-vis detector (HPLC-UV) for determination of phenol in environmental water while by using solid phase extraction (SPE) as s...
Main Author: | |
---|---|
Format: | Student Project |
Language: | English |
Published: |
2017
|
Subjects: | |
Online Access: | https://ir.uitm.edu.my/id/eprint/35055/1/35055.pdf |
_version_ | 1796903943722237952 |
---|---|
author | Haron, Nazurah |
author_facet | Haron, Nazurah |
author_sort | Haron, Nazurah |
collection | UITM |
description | Phenol as in water is harmful to living organism yet have a toxicity effect for a long-term exposure. In this research, the analysis was achieved on a C18 column coupled with UV-vis detector (HPLC-UV) for determination of phenol in environmental water while by using solid phase extraction (SPE) as sample preparation technique. The optimized variable involved in SPE and HPLC were as follow: 3 mL was used for load sample volume in SPE, 45 ± 3 drops min-1 was used for sample drop-rate in SPE and 0.35 mL min-1 as flow-rate on eluent in HPLC. The analytical method was validated based on the following parameter: precision, linear range, limit of detection (LOD), limit of quantitation (LOQ) and bias/recovery. A good linear correlation coefficient with R2 = 0.9996 was observed over the range of 0.55 - 30.0 µg mL-1. Both repeatability and reproducibility (RSD, %) were 0.215 and 1.490, respectively. The limit of detection was calculated to be 0.212 µg mL-1, while the limit of quantitation value of the validated method was measured to be 0.642 µg mL-1. Good recoveries were between 81 - 120%. The proposed method was found to be suitable and precise for the determination of phenol in environmental water by using HPLC. |
first_indexed | 2024-03-06T02:27:37Z |
format | Student Project |
id | oai:ir.uitm.edu.my:35055 |
institution | Universiti Teknologi MARA |
language | English |
last_indexed | 2024-03-06T02:27:37Z |
publishDate | 2017 |
record_format | dspace |
spelling | oai:ir.uitm.edu.my:350552020-10-12T04:18:51Z https://ir.uitm.edu.my/id/eprint/35055/ Determination of phenol in water sample using high performance liquid chromatography / Nazurah Haron Haron, Nazurah Laboratories. General works Extraction (Chemistry) Phenol as in water is harmful to living organism yet have a toxicity effect for a long-term exposure. In this research, the analysis was achieved on a C18 column coupled with UV-vis detector (HPLC-UV) for determination of phenol in environmental water while by using solid phase extraction (SPE) as sample preparation technique. The optimized variable involved in SPE and HPLC were as follow: 3 mL was used for load sample volume in SPE, 45 ± 3 drops min-1 was used for sample drop-rate in SPE and 0.35 mL min-1 as flow-rate on eluent in HPLC. The analytical method was validated based on the following parameter: precision, linear range, limit of detection (LOD), limit of quantitation (LOQ) and bias/recovery. A good linear correlation coefficient with R2 = 0.9996 was observed over the range of 0.55 - 30.0 µg mL-1. Both repeatability and reproducibility (RSD, %) were 0.215 and 1.490, respectively. The limit of detection was calculated to be 0.212 µg mL-1, while the limit of quantitation value of the validated method was measured to be 0.642 µg mL-1. Good recoveries were between 81 - 120%. The proposed method was found to be suitable and precise for the determination of phenol in environmental water by using HPLC. 2017 Student Project NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/35055/1/35055.pdf Determination of phenol in water sample using high performance liquid chromatography / Nazurah Haron. (2017) [Student Project] (Unpublished) |
spellingShingle | Laboratories. General works Extraction (Chemistry) Haron, Nazurah Determination of phenol in water sample using high performance liquid chromatography / Nazurah Haron |
title | Determination of phenol in water sample using high performance liquid chromatography / Nazurah Haron |
title_full | Determination of phenol in water sample using high performance liquid chromatography / Nazurah Haron |
title_fullStr | Determination of phenol in water sample using high performance liquid chromatography / Nazurah Haron |
title_full_unstemmed | Determination of phenol in water sample using high performance liquid chromatography / Nazurah Haron |
title_short | Determination of phenol in water sample using high performance liquid chromatography / Nazurah Haron |
title_sort | determination of phenol in water sample using high performance liquid chromatography nazurah haron |
topic | Laboratories. General works Extraction (Chemistry) |
url | https://ir.uitm.edu.my/id/eprint/35055/1/35055.pdf |
work_keys_str_mv | AT haronnazurah determinationofphenolinwatersampleusinghighperformanceliquidchromatographynazurahharon |