Evolutionary Programming (EP) based technique for secure point identification with load shedding technique in power transmission / Abdul Rahman Minhat

Voltage stability has been identified as a crucial issue in power system study which has been identified as one of the causes that lead to cascading power system blackout in many parts of the world. This phenomenon has made this subject a very relevant issue in power system planning and operat...

Full description

Bibliographic Details
Main Author: Minhat, Abdul Rahman
Format: Thesis
Language:English
Published: 2008
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/600/1/TM_ABDUL%20RAHMAN%20MINHAT%20EE%2008_5%201.pdf
_version_ 1796899207204831232
author Minhat, Abdul Rahman
author_facet Minhat, Abdul Rahman
author_sort Minhat, Abdul Rahman
collection UITM
description Voltage stability has been identified as a crucial issue in power system study which has been identified as one of the causes that lead to cascading power system blackout in many parts of the world. This phenomenon has made this subject a very relevant issue in power system planning and operation. This thesis presents the Evolutionary Programming (EP) based technique for secure point identification with load shedding technique in power transmission system. The study was initiated by the development of new algorithm for automatic voltage stability assessment (AVSA). This algorithm is used to estimate the maximum loadability point in power system. Consequently, another algorithm for maximum loadability identification using EP optimization technique was also developed. Several load buses have undergone maximum loadability tests for the determination of secure point prior to system instability occurrence, which may lead to possibility of voltage collapse in the system. In highlighting the merit of the proposed EP based technique for maximum loadability identification, established artificial immune system (AIS) optimization technique and AVSA were utilized for comparative studies purposes. The strength of EP in this study was evaluated in terms of its capability to search for the accurate solution and fast computation time. Consequently, the algorithm for load increase simultaneously at several load buses was also developed in order to search the optimal value at each bus in a system such that the system can maintain a stable condition. The ability of EP to search for the optimal values of multi-load increase as compared to AVSA which is only able to conduct uniform load increase at several load buses has been identified as the strength of EP over AVSA.
first_indexed 2024-03-06T01:17:39Z
format Thesis
id oai:ir.uitm.edu.my:600
institution Universiti Teknologi MARA
language English
last_indexed 2024-03-06T01:17:39Z
publishDate 2008
record_format dspace
spelling oai:ir.uitm.edu.my:6002016-07-01T04:05:37Z https://ir.uitm.edu.my/id/eprint/600/ Evolutionary Programming (EP) based technique for secure point identification with load shedding technique in power transmission / Abdul Rahman Minhat Minhat, Abdul Rahman TK Electrical engineering. Electronics. Nuclear engineering Production of electric energy or power. Powerplants. Central stations Electric power distribution. Electric power transmission Voltage stability has been identified as a crucial issue in power system study which has been identified as one of the causes that lead to cascading power system blackout in many parts of the world. This phenomenon has made this subject a very relevant issue in power system planning and operation. This thesis presents the Evolutionary Programming (EP) based technique for secure point identification with load shedding technique in power transmission system. The study was initiated by the development of new algorithm for automatic voltage stability assessment (AVSA). This algorithm is used to estimate the maximum loadability point in power system. Consequently, another algorithm for maximum loadability identification using EP optimization technique was also developed. Several load buses have undergone maximum loadability tests for the determination of secure point prior to system instability occurrence, which may lead to possibility of voltage collapse in the system. In highlighting the merit of the proposed EP based technique for maximum loadability identification, established artificial immune system (AIS) optimization technique and AVSA were utilized for comparative studies purposes. The strength of EP in this study was evaluated in terms of its capability to search for the accurate solution and fast computation time. Consequently, the algorithm for load increase simultaneously at several load buses was also developed in order to search the optimal value at each bus in a system such that the system can maintain a stable condition. The ability of EP to search for the optimal values of multi-load increase as compared to AVSA which is only able to conduct uniform load increase at several load buses has been identified as the strength of EP over AVSA. 2008 Thesis NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/600/1/TM_ABDUL%20RAHMAN%20MINHAT%20EE%2008_5%201.pdf Evolutionary Programming (EP) based technique for secure point identification with load shedding technique in power transmission / Abdul Rahman Minhat. (2008) Masters thesis, thesis, Universiti Teknologi MARA. <http://terminalib.uitm.edu.my/600.pdf>
spellingShingle TK Electrical engineering. Electronics. Nuclear engineering
Production of electric energy or power. Powerplants. Central stations
Electric power distribution. Electric power transmission
Minhat, Abdul Rahman
Evolutionary Programming (EP) based technique for secure point identification with load shedding technique in power transmission / Abdul Rahman Minhat
title Evolutionary Programming (EP) based technique for secure point identification with load shedding technique in power transmission / Abdul Rahman Minhat
title_full Evolutionary Programming (EP) based technique for secure point identification with load shedding technique in power transmission / Abdul Rahman Minhat
title_fullStr Evolutionary Programming (EP) based technique for secure point identification with load shedding technique in power transmission / Abdul Rahman Minhat
title_full_unstemmed Evolutionary Programming (EP) based technique for secure point identification with load shedding technique in power transmission / Abdul Rahman Minhat
title_short Evolutionary Programming (EP) based technique for secure point identification with load shedding technique in power transmission / Abdul Rahman Minhat
title_sort evolutionary programming ep based technique for secure point identification with load shedding technique in power transmission abdul rahman minhat
topic TK Electrical engineering. Electronics. Nuclear engineering
Production of electric energy or power. Powerplants. Central stations
Electric power distribution. Electric power transmission
url https://ir.uitm.edu.my/id/eprint/600/1/TM_ABDUL%20RAHMAN%20MINHAT%20EE%2008_5%201.pdf
work_keys_str_mv AT minhatabdulrahman evolutionaryprogrammingepbasedtechniqueforsecurepointidentificationwithloadsheddingtechniqueinpowertransmissionabdulrahmanminhat