Ductility performance of wall-slab joint in Industrialized Building System (IBS) subjected to lateral reversible cyclic loading / Mohd Ashaari Masrom, Nor Hayati Abdul Hamid and Mohd Azrizal Fauzi

Connections between floor slab and shear walls constitute an essential link in the lateral load-resisting mechanism of slab-wall of reinforced concrete building. The ductility performance of wall-slab joint influences the pattern and distribution of lateral forces among the vertical elements of a st...

Full description

Bibliographic Details
Main Authors: Masrom, Mohd Ashaari, Abdul Hamid, Nor Hayati, Fauzi, Mohd Azrizal
Format: Article
Published: Universiti Teknologi MARA, Pulau Pinang & Pusat Penerbitan Universiti (UPENA) 2012
Subjects:
_version_ 1796899585913782272
author Masrom, Mohd Ashaari
Abdul Hamid, Nor Hayati
Fauzi, Mohd Azrizal
author_facet Masrom, Mohd Ashaari
Abdul Hamid, Nor Hayati
Fauzi, Mohd Azrizal
author_sort Masrom, Mohd Ashaari
collection UITM
description Connections between floor slab and shear walls constitute an essential link in the lateral load-resisting mechanism of slab-wall of reinforced concrete building. The ductility performance of wall-slab joint influences the pattern and distribution of lateral forces among the vertical elements of a structure. This study presents the results of an experimental investigation on the ductility performance of wall-slab connection which is designed in accordance to BS 8110. The experiment work includes full-scale test of wall-slab connection under reversible lateral cyclic loading. This study focuses on ductility performance of wall-slab connection under reversible cyclic loading. The hysteresis loops was developed based on experiment data to determine the ductility of wall-slab joint under reversible cyclic loading. The theoretical background was formulated to validate the result of experiment. There was a good agreement between them. Therefore, the ductility of the joint was determined and designed accordingly. The results indicate that the wall-slab connection was governed by brittle failure modes in reinforced concrete. This is due to low ductility which resulted in the inability of the connection to absorb energy efficiently and therefore further undergoes inelastic deformation. In fact, the brittle failure modes did not allow the energy dissipation and lead to sudden failure without warning to the structures as experienced by the Reinforced Concrete (RC) buildings during earthquakes
first_indexed 2024-03-06T01:23:15Z
format Article
id oai:ir.uitm.edu.my:8858
institution Universiti Teknologi MARA
last_indexed 2024-03-06T01:23:15Z
publishDate 2012
publisher Universiti Teknologi MARA, Pulau Pinang & Pusat Penerbitan Universiti (UPENA)
record_format dspace
spelling oai:ir.uitm.edu.my:88582017-09-21T08:10:45Z https://ir.uitm.edu.my/id/eprint/8858/ Ductility performance of wall-slab joint in Industrialized Building System (IBS) subjected to lateral reversible cyclic loading / Mohd Ashaari Masrom, Nor Hayati Abdul Hamid and Mohd Azrizal Fauzi esteem Masrom, Mohd Ashaari Abdul Hamid, Nor Hayati Fauzi, Mohd Azrizal Systems engineering Architectural engineering. Structural engineering of buildings Connections between floor slab and shear walls constitute an essential link in the lateral load-resisting mechanism of slab-wall of reinforced concrete building. The ductility performance of wall-slab joint influences the pattern and distribution of lateral forces among the vertical elements of a structure. This study presents the results of an experimental investigation on the ductility performance of wall-slab connection which is designed in accordance to BS 8110. The experiment work includes full-scale test of wall-slab connection under reversible lateral cyclic loading. This study focuses on ductility performance of wall-slab connection under reversible cyclic loading. The hysteresis loops was developed based on experiment data to determine the ductility of wall-slab joint under reversible cyclic loading. The theoretical background was formulated to validate the result of experiment. There was a good agreement between them. Therefore, the ductility of the joint was determined and designed accordingly. The results indicate that the wall-slab connection was governed by brittle failure modes in reinforced concrete. This is due to low ductility which resulted in the inability of the connection to absorb energy efficiently and therefore further undergoes inelastic deformation. In fact, the brittle failure modes did not allow the energy dissipation and lead to sudden failure without warning to the structures as experienced by the Reinforced Concrete (RC) buildings during earthquakes Universiti Teknologi MARA, Pulau Pinang & Pusat Penerbitan Universiti (UPENA) 2012 Article PeerReviewed Ductility performance of wall-slab joint in Industrialized Building System (IBS) subjected to lateral reversible cyclic loading / Mohd Ashaari Masrom, Nor Hayati Abdul Hamid and Mohd Azrizal Fauzi. (2012) Esteem Academic Journal <https://ir.uitm.edu.my/view/publication/Esteem_Academic_Journal/>, 8 (1). pp. 15-27. ISSN 1675-7939
spellingShingle Systems engineering
Architectural engineering. Structural engineering of buildings
Masrom, Mohd Ashaari
Abdul Hamid, Nor Hayati
Fauzi, Mohd Azrizal
Ductility performance of wall-slab joint in Industrialized Building System (IBS) subjected to lateral reversible cyclic loading / Mohd Ashaari Masrom, Nor Hayati Abdul Hamid and Mohd Azrizal Fauzi
title Ductility performance of wall-slab joint in Industrialized Building System (IBS) subjected to lateral reversible cyclic loading / Mohd Ashaari Masrom, Nor Hayati Abdul Hamid and Mohd Azrizal Fauzi
title_full Ductility performance of wall-slab joint in Industrialized Building System (IBS) subjected to lateral reversible cyclic loading / Mohd Ashaari Masrom, Nor Hayati Abdul Hamid and Mohd Azrizal Fauzi
title_fullStr Ductility performance of wall-slab joint in Industrialized Building System (IBS) subjected to lateral reversible cyclic loading / Mohd Ashaari Masrom, Nor Hayati Abdul Hamid and Mohd Azrizal Fauzi
title_full_unstemmed Ductility performance of wall-slab joint in Industrialized Building System (IBS) subjected to lateral reversible cyclic loading / Mohd Ashaari Masrom, Nor Hayati Abdul Hamid and Mohd Azrizal Fauzi
title_short Ductility performance of wall-slab joint in Industrialized Building System (IBS) subjected to lateral reversible cyclic loading / Mohd Ashaari Masrom, Nor Hayati Abdul Hamid and Mohd Azrizal Fauzi
title_sort ductility performance of wall slab joint in industrialized building system ibs subjected to lateral reversible cyclic loading mohd ashaari masrom nor hayati abdul hamid and mohd azrizal fauzi
topic Systems engineering
Architectural engineering. Structural engineering of buildings
work_keys_str_mv AT masrommohdashaari ductilityperformanceofwallslabjointinindustrializedbuildingsystemibssubjectedtolateralreversiblecyclicloadingmohdashaarimasromnorhayatiabdulhamidandmohdazrizalfauzi
AT abdulhamidnorhayati ductilityperformanceofwallslabjointinindustrializedbuildingsystemibssubjectedtolateralreversiblecyclicloadingmohdashaarimasromnorhayatiabdulhamidandmohdazrizalfauzi
AT fauzimohdazrizal ductilityperformanceofwallslabjointinindustrializedbuildingsystemibssubjectedtolateralreversiblecyclicloadingmohdashaarimasromnorhayatiabdulhamidandmohdazrizalfauzi