Ductility performance of wall-slab joint in Industrialized Building System (IBS) subjected to lateral reversible cyclic loading / Mohd Ashaari Masrom, Nor Hayati Abdul Hamid and Mohd Azrizal Fauzi
Connections between floor slab and shear walls constitute an essential link in the lateral load-resisting mechanism of slab-wall of reinforced concrete building. The ductility performance of wall-slab joint influences the pattern and distribution of lateral forces among the vertical elements of a st...