Improvement of haemodynamic stent strut configuration for patent ductus arteriosus through computational modelling

Thesis (Ph.D (Mechanical Engineering))

Bibliographic Details
Main Author: Taib, Ishkrizat
Format: Thesis
Language:English
Published: Universiti Teknologi Malaysia 2024
Subjects:
Online Access:https://openscience.utm.my/handle/123456789/1523
_version_ 1824446320021078016
author Taib, Ishkrizat
author_facet Taib, Ishkrizat
author_sort Taib, Ishkrizat
collection OpenScience
description Thesis (Ph.D (Mechanical Engineering))
first_indexed 2025-02-19T01:13:17Z
format Thesis
id oai:openscience.utm.my:123456789/1523
institution Universiti Teknologi Malaysia - OpenScience
language English
last_indexed 2025-02-19T01:13:17Z
publishDate 2024
publisher Universiti Teknologi Malaysia
record_format dspace
spelling oai:openscience.utm.my:123456789/15232024-12-18T10:00:36Z Improvement of haemodynamic stent strut configuration for patent ductus arteriosus through computational modelling Taib, Ishkrizat Hemodynamics Patent ductus arteriosus Thesis (Ph.D (Mechanical Engineering)) Currently, the treatment of Patent Ductus Arteriosus (PDA) by the implantation of coronary stent has resulted in severe hemodynamic complications. There is thus a need to customize and improve current stent geometry specific to PDA to overcome this problem. Computational Fluid Dynamics (CFD) approaches, verified by an experimental technique are used to analyze current stent strut configurations. Statistical analysis is used to rank the parameter performance and to obtain the best stent configuration. The most favorable configuration is then used to design new stent strut configuration specific for PDA. In the analysis of the new stent design, CFD results show low possibility of re-stenosis process due to thrombosis formation, inflammation, and neo-intimal hyperplasia. Furthermore, comprehensive CFD analysis by solving fluid-structure interaction (FSI) cases has produced an optimum stent strut configuration that is structurally sound. The strength of stent strut configuration due to hemodynamic effect is analyzed through the Von Misses stress distribution. The results show that the new improved design of stent strut configuration has excellent hemodynamic performance. Finally, the new stent design is predicted to be able to overcome hemodynamic complications and stent structural failure when applied specifically to PDA Faculty of Mechanical Engineering 2024-12-18T01:51:55Z 2024-12-18T01:51:55Z 2016 Thesis Dataset https://openscience.utm.my/handle/123456789/1523 en application/pdf application/pdf application/pdf Universiti Teknologi Malaysia
spellingShingle Hemodynamics
Patent ductus arteriosus
Taib, Ishkrizat
Improvement of haemodynamic stent strut configuration for patent ductus arteriosus through computational modelling
title Improvement of haemodynamic stent strut configuration for patent ductus arteriosus through computational modelling
title_full Improvement of haemodynamic stent strut configuration for patent ductus arteriosus through computational modelling
title_fullStr Improvement of haemodynamic stent strut configuration for patent ductus arteriosus through computational modelling
title_full_unstemmed Improvement of haemodynamic stent strut configuration for patent ductus arteriosus through computational modelling
title_short Improvement of haemodynamic stent strut configuration for patent ductus arteriosus through computational modelling
title_sort improvement of haemodynamic stent strut configuration for patent ductus arteriosus through computational modelling
topic Hemodynamics
Patent ductus arteriosus
url https://openscience.utm.my/handle/123456789/1523
work_keys_str_mv AT taibishkrizat improvementofhaemodynamicstentstrutconfigurationforpatentductusarteriosusthroughcomputationalmodelling