Production and validation of CR-39-based dishes for alpha-particle radiobiological experiments.

The study of radiobiological effects induced in vitro by low fluences of alpha particles would be significantly enhanced if the precise localization of each particle track in the cell monolayer was known. From this perspective, we developed a new method based on tailor-made UV-radiation-cured CR-39,...

Full description

Bibliographic Details
Main Authors: Gaillard, S, Armbruster, V, Hill, M, Gharbi, T, Fromm, M
Format: Journal article
Language:English
Published: 2005
_version_ 1797050239908052992
author Gaillard, S
Armbruster, V
Hill, M
Gharbi, T
Fromm, M
author_facet Gaillard, S
Armbruster, V
Hill, M
Gharbi, T
Fromm, M
author_sort Gaillard, S
collection OXFORD
description The study of radiobiological effects induced in vitro by low fluences of alpha particles would be significantly enhanced if the precise localization of each particle track in the cell monolayer was known. From this perspective, we developed a new method based on tailor-made UV-radiation-cured CR-39, the production of which is described. Its validation both as a petri dish and as solid-state nuclear track detectors is demonstrated. With respect to the demands on solid-state nuclear track detectors in such experiments, these biologically compatible detectors have a controlled micrometric thickness that allows them to be crossed by the alpha particles. In this study, we present a method for obtaining 10-mum-thick CR-39, its chemical characterization, and its properties as a solid-state nuclear track detector under the environmental conditions of radiobiological experiments. The experimental studies performed with 3.5 MeV alpha particles show that their transmitted energy is sufficient enough to cross the entire cellular volume. Under optimal conditions, etched tracks are clearly defined 2 h after etching. Moreover, the UV-radiation-cured CR-39 represents an essentially zero background that is due to the short time between the production and use of the polymer. Under a confocal microscope, this thin solid-state nuclear track detector allows the precise localization of the impact parameter at the subcellular level.
first_indexed 2024-03-06T18:02:14Z
format Journal article
id oxford-uuid:002dfbe0-2a19-4abf-9b36-97301405f0d7
institution University of Oxford
language English
last_indexed 2024-03-06T18:02:14Z
publishDate 2005
record_format dspace
spelling oxford-uuid:002dfbe0-2a19-4abf-9b36-97301405f0d72022-03-26T08:28:10ZProduction and validation of CR-39-based dishes for alpha-particle radiobiological experiments.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:002dfbe0-2a19-4abf-9b36-97301405f0d7EnglishSymplectic Elements at Oxford2005Gaillard, SArmbruster, VHill, MGharbi, TFromm, MThe study of radiobiological effects induced in vitro by low fluences of alpha particles would be significantly enhanced if the precise localization of each particle track in the cell monolayer was known. From this perspective, we developed a new method based on tailor-made UV-radiation-cured CR-39, the production of which is described. Its validation both as a petri dish and as solid-state nuclear track detectors is demonstrated. With respect to the demands on solid-state nuclear track detectors in such experiments, these biologically compatible detectors have a controlled micrometric thickness that allows them to be crossed by the alpha particles. In this study, we present a method for obtaining 10-mum-thick CR-39, its chemical characterization, and its properties as a solid-state nuclear track detector under the environmental conditions of radiobiological experiments. The experimental studies performed with 3.5 MeV alpha particles show that their transmitted energy is sufficient enough to cross the entire cellular volume. Under optimal conditions, etched tracks are clearly defined 2 h after etching. Moreover, the UV-radiation-cured CR-39 represents an essentially zero background that is due to the short time between the production and use of the polymer. Under a confocal microscope, this thin solid-state nuclear track detector allows the precise localization of the impact parameter at the subcellular level.
spellingShingle Gaillard, S
Armbruster, V
Hill, M
Gharbi, T
Fromm, M
Production and validation of CR-39-based dishes for alpha-particle radiobiological experiments.
title Production and validation of CR-39-based dishes for alpha-particle radiobiological experiments.
title_full Production and validation of CR-39-based dishes for alpha-particle radiobiological experiments.
title_fullStr Production and validation of CR-39-based dishes for alpha-particle radiobiological experiments.
title_full_unstemmed Production and validation of CR-39-based dishes for alpha-particle radiobiological experiments.
title_short Production and validation of CR-39-based dishes for alpha-particle radiobiological experiments.
title_sort production and validation of cr 39 based dishes for alpha particle radiobiological experiments
work_keys_str_mv AT gaillards productionandvalidationofcr39baseddishesforalphaparticleradiobiologicalexperiments
AT armbrusterv productionandvalidationofcr39baseddishesforalphaparticleradiobiologicalexperiments
AT hillm productionandvalidationofcr39baseddishesforalphaparticleradiobiologicalexperiments
AT gharbit productionandvalidationofcr39baseddishesforalphaparticleradiobiologicalexperiments
AT frommm productionandvalidationofcr39baseddishesforalphaparticleradiobiologicalexperiments