Methodology and technology for peripheral and central blood pressure and blood pressure variability measurement: current status and future directions - Position statement of the European Society of Hypertension Working Group on blood pressure monitoring and cardiovascular variability

Office blood pressure measurement has been the basis for hypertension evaluation for almost a century. However, the evaluation of blood pressure out of the office using ambulatory or self-home monitoring is now strongly recommended for the accurate diagnosis in many, if not all, cases with suspected...

Description complète

Détails bibliographiques
Auteurs principaux: Stergiou, GS, Parati, G, Vlachopoulos, C, McManus, R
Format: Journal article
Langue:English
Publié: Lippincott, Williams & Wilkins 2017
_version_ 1826256959658000384
author Stergiou, GS
Parati, G
Vlachopoulos, C
McManus, R
author_facet Stergiou, GS
Parati, G
Vlachopoulos, C
McManus, R
author_sort Stergiou, GS
collection OXFORD
description Office blood pressure measurement has been the basis for hypertension evaluation for almost a century. However, the evaluation of blood pressure out of the office using ambulatory or self-home monitoring is now strongly recommended for the accurate diagnosis in many, if not all, cases with suspected hypertension. Moreover, there is evidence that the variability of blood pressure might offer prognostic information that is independent of the average blood pressure level. Recently, advancement in technology has provided noninvasive evaluation of central (aortic) blood pressure, which might have attributes that are additive to the conventional brachial blood pressure measurement. This position statement, developed by international experts, deals with key research and practical issues in regard to peripheral blood pressure measurement (office, home, and ambulatory), blood pressure variability, and central blood pressure measurement. The objective is to present current achievements, identify gaps in knowledge and issues concerning clinical application, and present relevant research questions and directions to investigators and manufacturers for future research and development (primary goal).
first_indexed 2024-03-06T18:10:33Z
format Journal article
id oxford-uuid:02e03563-de1c-40e1-abd8-c7df3623bc35
institution University of Oxford
language English
last_indexed 2024-03-06T18:10:33Z
publishDate 2017
publisher Lippincott, Williams & Wilkins
record_format dspace
spelling oxford-uuid:02e03563-de1c-40e1-abd8-c7df3623bc352022-03-26T08:43:08ZMethodology and technology for peripheral and central blood pressure and blood pressure variability measurement: current status and future directions - Position statement of the European Society of Hypertension Working Group on blood pressure monitoring and cardiovascular variabilityJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:02e03563-de1c-40e1-abd8-c7df3623bc35EnglishSymplectic Elements at OxfordLippincott, Williams & Wilkins2017Stergiou, GSParati, GVlachopoulos, CMcManus, ROffice blood pressure measurement has been the basis for hypertension evaluation for almost a century. However, the evaluation of blood pressure out of the office using ambulatory or self-home monitoring is now strongly recommended for the accurate diagnosis in many, if not all, cases with suspected hypertension. Moreover, there is evidence that the variability of blood pressure might offer prognostic information that is independent of the average blood pressure level. Recently, advancement in technology has provided noninvasive evaluation of central (aortic) blood pressure, which might have attributes that are additive to the conventional brachial blood pressure measurement. This position statement, developed by international experts, deals with key research and practical issues in regard to peripheral blood pressure measurement (office, home, and ambulatory), blood pressure variability, and central blood pressure measurement. The objective is to present current achievements, identify gaps in knowledge and issues concerning clinical application, and present relevant research questions and directions to investigators and manufacturers for future research and development (primary goal).
spellingShingle Stergiou, GS
Parati, G
Vlachopoulos, C
McManus, R
Methodology and technology for peripheral and central blood pressure and blood pressure variability measurement: current status and future directions - Position statement of the European Society of Hypertension Working Group on blood pressure monitoring and cardiovascular variability
title Methodology and technology for peripheral and central blood pressure and blood pressure variability measurement: current status and future directions - Position statement of the European Society of Hypertension Working Group on blood pressure monitoring and cardiovascular variability
title_full Methodology and technology for peripheral and central blood pressure and blood pressure variability measurement: current status and future directions - Position statement of the European Society of Hypertension Working Group on blood pressure monitoring and cardiovascular variability
title_fullStr Methodology and technology for peripheral and central blood pressure and blood pressure variability measurement: current status and future directions - Position statement of the European Society of Hypertension Working Group on blood pressure monitoring and cardiovascular variability
title_full_unstemmed Methodology and technology for peripheral and central blood pressure and blood pressure variability measurement: current status and future directions - Position statement of the European Society of Hypertension Working Group on blood pressure monitoring and cardiovascular variability
title_short Methodology and technology for peripheral and central blood pressure and blood pressure variability measurement: current status and future directions - Position statement of the European Society of Hypertension Working Group on blood pressure monitoring and cardiovascular variability
title_sort methodology and technology for peripheral and central blood pressure and blood pressure variability measurement current status and future directions position statement of the european society of hypertension working group on blood pressure monitoring and cardiovascular variability
work_keys_str_mv AT stergiougs methodologyandtechnologyforperipheralandcentralbloodpressureandbloodpressurevariabilitymeasurementcurrentstatusandfuturedirectionspositionstatementoftheeuropeansocietyofhypertensionworkinggrouponbloodpressuremonitoringandcardiovascularvariability
AT paratig methodologyandtechnologyforperipheralandcentralbloodpressureandbloodpressurevariabilitymeasurementcurrentstatusandfuturedirectionspositionstatementoftheeuropeansocietyofhypertensionworkinggrouponbloodpressuremonitoringandcardiovascularvariability
AT vlachopoulosc methodologyandtechnologyforperipheralandcentralbloodpressureandbloodpressurevariabilitymeasurementcurrentstatusandfuturedirectionspositionstatementoftheeuropeansocietyofhypertensionworkinggrouponbloodpressuremonitoringandcardiovascularvariability
AT mcmanusr methodologyandtechnologyforperipheralandcentralbloodpressureandbloodpressurevariabilitymeasurementcurrentstatusandfuturedirectionspositionstatementoftheeuropeansocietyofhypertensionworkinggrouponbloodpressuremonitoringandcardiovascularvariability