Moment loading of caissons installed in saturated sand

A series of moment capacity tests have been carried out at model scale, to investigate the effects of different installation procedures on the response of suction caisson foundations in sand. Two caissons of different diameters and wall thicknesses, but similar skirt length to diameter ratio, have b...

Full description

Bibliographic Details
Main Authors: Villalobos, F, Byrne, B, Houlsby, G
Format: Conference item
Published: 2005
_version_ 1826257015642521600
author Villalobos, F
Byrne, B
Houlsby, G
author_facet Villalobos, F
Byrne, B
Houlsby, G
author_sort Villalobos, F
collection OXFORD
description A series of moment capacity tests have been carried out at model scale, to investigate the effects of different installation procedures on the response of suction caisson foundations in sand. Two caissons of different diameters and wall thicknesses, but similar skirt length to diameter ratio, have been tested in watersaturated dense sand. The caissons were installed either by pushing or by using suction. It was found that the moment resistance depends on the method of installation. © 2005 Taylor and Francis Group.
first_indexed 2024-03-06T18:11:25Z
format Conference item
id oxford-uuid:032c8d22-e46c-40a3-9775-984879f788a8
institution University of Oxford
last_indexed 2024-03-06T18:11:25Z
publishDate 2005
record_format dspace
spelling oxford-uuid:032c8d22-e46c-40a3-9775-984879f788a82022-03-26T08:44:30ZMoment loading of caissons installed in saturated sandConference itemhttp://purl.org/coar/resource_type/c_5794uuid:032c8d22-e46c-40a3-9775-984879f788a8Symplectic Elements at Oxford2005Villalobos, FByrne, BHoulsby, GA series of moment capacity tests have been carried out at model scale, to investigate the effects of different installation procedures on the response of suction caisson foundations in sand. Two caissons of different diameters and wall thicknesses, but similar skirt length to diameter ratio, have been tested in watersaturated dense sand. The caissons were installed either by pushing or by using suction. It was found that the moment resistance depends on the method of installation. © 2005 Taylor and Francis Group.
spellingShingle Villalobos, F
Byrne, B
Houlsby, G
Moment loading of caissons installed in saturated sand
title Moment loading of caissons installed in saturated sand
title_full Moment loading of caissons installed in saturated sand
title_fullStr Moment loading of caissons installed in saturated sand
title_full_unstemmed Moment loading of caissons installed in saturated sand
title_short Moment loading of caissons installed in saturated sand
title_sort moment loading of caissons installed in saturated sand
work_keys_str_mv AT villalobosf momentloadingofcaissonsinstalledinsaturatedsand
AT byrneb momentloadingofcaissonsinstalledinsaturatedsand
AT houlsbyg momentloadingofcaissonsinstalledinsaturatedsand