HIFU-induced cavitation and heating in ex vivo porcine subcutaneous fat.

The present study is motivated by the fact that there are no published studies quantifying cavitation activity and heating induced by ultrasound in adipose tissue and that there are currently no reliable techniques for monitoring successful deposition of ultrasound energy in fat in real time. High-i...

Full description

Bibliographic Details
Main Authors: Kyriakou, Z, Corral-Baques, M, Amat, A, Coussios, C
Format: Journal article
Language:English
Published: 2011
_version_ 1797052094819074048
author Kyriakou, Z
Corral-Baques, M
Amat, A
Coussios, C
author_facet Kyriakou, Z
Corral-Baques, M
Amat, A
Coussios, C
author_sort Kyriakou, Z
collection OXFORD
description The present study is motivated by the fact that there are no published studies quantifying cavitation activity and heating induced by ultrasound in adipose tissue and that there are currently no reliable techniques for monitoring successful deposition of ultrasound energy in fat in real time. High-intensity focused ultrasound (HIFU) exposures were performed in excised porcine fat at four different frequencies (0.5, 1.1, 1.6 and 3.4 MHz) over a range of pressure amplitudes and exposure durations. The transmission losses arising from reflection at the skin interface and attenuation through skin and fat were quantified at all frequencies using an embedded needle hydrophone. A 15 MHz passive cavitation detector (PCD) coaxial to the HIFU transducer was used to capture acoustic emissions emanating from the focus during HIFU exposures, while the focal temperature rise was measured using minimally invasive needle thermocouples. Repeatable temperature rises in excess of 10°C could be readily instigated across all four frequencies for acoustic intensities (Ispta) in excess of 50 W/cm(2) within the first 2 s of exposure. Even though cavitation could not be initiated at 1.1, 1.6 and 3.4 MHz over the in situ peak rarefactional (p(-)) pressure range 0-3 MPa explored in the present study, inertial cavitation activity was always initiated at 0.5 MHz for pressures greater than 1.6 MPa (p(-)) and was found to enhance focal heat deposition. A good correlation was identified between the energy of broadband emissions detected by the PCD and the focal temperature rise at 0.5 MHz, particularly for short 2 s exposures, which could be exploited as a tool for noninvasive monitoring of successful treatment delivery.
first_indexed 2024-03-06T18:27:54Z
format Journal article
id oxford-uuid:089f8911-e549-4277-8a35-e5c3eb329530
institution University of Oxford
language English
last_indexed 2024-03-06T18:27:54Z
publishDate 2011
record_format dspace
spelling oxford-uuid:089f8911-e549-4277-8a35-e5c3eb3295302022-03-26T09:13:51ZHIFU-induced cavitation and heating in ex vivo porcine subcutaneous fat.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:089f8911-e549-4277-8a35-e5c3eb329530EnglishSymplectic Elements at Oxford2011Kyriakou, ZCorral-Baques, MAmat, ACoussios, CThe present study is motivated by the fact that there are no published studies quantifying cavitation activity and heating induced by ultrasound in adipose tissue and that there are currently no reliable techniques for monitoring successful deposition of ultrasound energy in fat in real time. High-intensity focused ultrasound (HIFU) exposures were performed in excised porcine fat at four different frequencies (0.5, 1.1, 1.6 and 3.4 MHz) over a range of pressure amplitudes and exposure durations. The transmission losses arising from reflection at the skin interface and attenuation through skin and fat were quantified at all frequencies using an embedded needle hydrophone. A 15 MHz passive cavitation detector (PCD) coaxial to the HIFU transducer was used to capture acoustic emissions emanating from the focus during HIFU exposures, while the focal temperature rise was measured using minimally invasive needle thermocouples. Repeatable temperature rises in excess of 10°C could be readily instigated across all four frequencies for acoustic intensities (Ispta) in excess of 50 W/cm(2) within the first 2 s of exposure. Even though cavitation could not be initiated at 1.1, 1.6 and 3.4 MHz over the in situ peak rarefactional (p(-)) pressure range 0-3 MPa explored in the present study, inertial cavitation activity was always initiated at 0.5 MHz for pressures greater than 1.6 MPa (p(-)) and was found to enhance focal heat deposition. A good correlation was identified between the energy of broadband emissions detected by the PCD and the focal temperature rise at 0.5 MHz, particularly for short 2 s exposures, which could be exploited as a tool for noninvasive monitoring of successful treatment delivery.
spellingShingle Kyriakou, Z
Corral-Baques, M
Amat, A
Coussios, C
HIFU-induced cavitation and heating in ex vivo porcine subcutaneous fat.
title HIFU-induced cavitation and heating in ex vivo porcine subcutaneous fat.
title_full HIFU-induced cavitation and heating in ex vivo porcine subcutaneous fat.
title_fullStr HIFU-induced cavitation and heating in ex vivo porcine subcutaneous fat.
title_full_unstemmed HIFU-induced cavitation and heating in ex vivo porcine subcutaneous fat.
title_short HIFU-induced cavitation and heating in ex vivo porcine subcutaneous fat.
title_sort hifu induced cavitation and heating in ex vivo porcine subcutaneous fat
work_keys_str_mv AT kyriakouz hifuinducedcavitationandheatinginexvivoporcinesubcutaneousfat
AT corralbaquesm hifuinducedcavitationandheatinginexvivoporcinesubcutaneousfat
AT amata hifuinducedcavitationandheatinginexvivoporcinesubcutaneousfat
AT coussiosc hifuinducedcavitationandheatinginexvivoporcinesubcutaneousfat