Status of construction and first tests of the CLEO III RICH

The CLEO collaboration is preparing a major upgrade of its present detector including a RICH detector for particle identification. This subdetector system follows the 'proximity focussing' design and uses LiF crystal radiators and MWPCs filled with a CH4/TEA gas mixture as photon detector....

Full description

Bibliographic Details
Main Authors: Artuso, M, Azfar, F, Efimov, A, Kopp, S, Mountain, R, Schuh, S, Skwarnicki, T, Stone, S, Viehhauser, G, Anderson, S, Smith, A, Kubota, Y, Lipeles, E, Coan, T, Staeck, J, Fadeyev, V, Volobouev, I, Ye, J
Format: Conference item
Published: 1998
_version_ 1797052582745604096
author Artuso, M
Azfar, F
Efimov, A
Kopp, S
Mountain, R
Schuh, S
Skwarnicki, T
Stone, S
Viehhauser, G
Anderson, S
Smith, A
Kubota, Y
Lipeles, E
Coan, T
Staeck, J
Fadeyev, V
Volobouev, I
Ye, J
author_facet Artuso, M
Azfar, F
Efimov, A
Kopp, S
Mountain, R
Schuh, S
Skwarnicki, T
Stone, S
Viehhauser, G
Anderson, S
Smith, A
Kubota, Y
Lipeles, E
Coan, T
Staeck, J
Fadeyev, V
Volobouev, I
Ye, J
author_sort Artuso, M
collection OXFORD
description The CLEO collaboration is preparing a major upgrade of its present detector including a RICH detector for particle identification. This subdetector system follows the 'proximity focussing' design and uses LiF crystal radiators and MWPCs filled with a CH4/TEA gas mixture as photon detector. Part of the radiator crystals will have the new 'sawtooth' geometry.We have constructed two of the 30 detector modules and tested these together with the first planar and 'sawtooth' radiator crystals in a muon halo beam at Fermilab. For the measurement of the Cherenkov angle we obtain a single photon measurement error of 13.5 mrad for the conventional planar radiator. With 14 detected photons we find a resolution per track of 4.5 mrad. In the first measurement ever of a 'sawtooth' radiator we achieve a resolution of 11.8 mrad for single photons and 4.8 mrad per track for 12.3 detected photons with a reduced geometric acceptance. These results fulfill CLEO III requirements.
first_indexed 2024-03-06T18:33:34Z
format Conference item
id oxford-uuid:0a79785a-cfb8-469a-a0b0-0f12fc71f9e3
institution University of Oxford
last_indexed 2024-03-06T18:33:34Z
publishDate 1998
record_format dspace
spelling oxford-uuid:0a79785a-cfb8-469a-a0b0-0f12fc71f9e32022-03-26T09:24:04ZStatus of construction and first tests of the CLEO III RICHConference itemhttp://purl.org/coar/resource_type/c_5794uuid:0a79785a-cfb8-469a-a0b0-0f12fc71f9e3Symplectic Elements at Oxford1998Artuso, MAzfar, FEfimov, AKopp, SMountain, RSchuh, SSkwarnicki, TStone, SViehhauser, GAnderson, SSmith, AKubota, YLipeles, ECoan, TStaeck, JFadeyev, VVolobouev, IYe, JThe CLEO collaboration is preparing a major upgrade of its present detector including a RICH detector for particle identification. This subdetector system follows the 'proximity focussing' design and uses LiF crystal radiators and MWPCs filled with a CH4/TEA gas mixture as photon detector. Part of the radiator crystals will have the new 'sawtooth' geometry.We have constructed two of the 30 detector modules and tested these together with the first planar and 'sawtooth' radiator crystals in a muon halo beam at Fermilab. For the measurement of the Cherenkov angle we obtain a single photon measurement error of 13.5 mrad for the conventional planar radiator. With 14 detected photons we find a resolution per track of 4.5 mrad. In the first measurement ever of a 'sawtooth' radiator we achieve a resolution of 11.8 mrad for single photons and 4.8 mrad per track for 12.3 detected photons with a reduced geometric acceptance. These results fulfill CLEO III requirements.
spellingShingle Artuso, M
Azfar, F
Efimov, A
Kopp, S
Mountain, R
Schuh, S
Skwarnicki, T
Stone, S
Viehhauser, G
Anderson, S
Smith, A
Kubota, Y
Lipeles, E
Coan, T
Staeck, J
Fadeyev, V
Volobouev, I
Ye, J
Status of construction and first tests of the CLEO III RICH
title Status of construction and first tests of the CLEO III RICH
title_full Status of construction and first tests of the CLEO III RICH
title_fullStr Status of construction and first tests of the CLEO III RICH
title_full_unstemmed Status of construction and first tests of the CLEO III RICH
title_short Status of construction and first tests of the CLEO III RICH
title_sort status of construction and first tests of the cleo iii rich
work_keys_str_mv AT artusom statusofconstructionandfirsttestsofthecleoiiirich
AT azfarf statusofconstructionandfirsttestsofthecleoiiirich
AT efimova statusofconstructionandfirsttestsofthecleoiiirich
AT kopps statusofconstructionandfirsttestsofthecleoiiirich
AT mountainr statusofconstructionandfirsttestsofthecleoiiirich
AT schuhs statusofconstructionandfirsttestsofthecleoiiirich
AT skwarnickit statusofconstructionandfirsttestsofthecleoiiirich
AT stones statusofconstructionandfirsttestsofthecleoiiirich
AT viehhauserg statusofconstructionandfirsttestsofthecleoiiirich
AT andersons statusofconstructionandfirsttestsofthecleoiiirich
AT smitha statusofconstructionandfirsttestsofthecleoiiirich
AT kubotay statusofconstructionandfirsttestsofthecleoiiirich
AT lipelese statusofconstructionandfirsttestsofthecleoiiirich
AT coant statusofconstructionandfirsttestsofthecleoiiirich
AT staeckj statusofconstructionandfirsttestsofthecleoiiirich
AT fadeyevv statusofconstructionandfirsttestsofthecleoiiirich
AT volobouevi statusofconstructionandfirsttestsofthecleoiiirich
AT yej statusofconstructionandfirsttestsofthecleoiiirich